{"id":1912,"date":"2022-06-22T10:30:34","date_gmt":"2022-06-22T10:30:34","guid":{"rendered":"https:\/\/csiag.eu\/?p=1912"},"modified":"2025-10-24T18:05:27","modified_gmt":"2025-10-24T18:05:27","slug":"sterilizace-vody-uv-c","status":"publish","type":"post","link":"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/","title":{"rendered":"Sterilizace vody pomoc\u00ed UV-C"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Obsah<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Studien\" >Studie<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Die_Theorie_%E2%80%A6\" >Teorie ...<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Strahlungs-Dosis\" >D\u00e1vka z\u00e1\u0159en\u00ed<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#%E2%80%A6_und_die_Praxis\" >... a praxe<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Wahl_des_Einbauortes\" >Volba m\u00edsta instalace<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Besonderheit_Druckpumpe\" >Speci\u00e1ln\u00ed funkce tlakov\u00e9ho \u010derpadla<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Doba \u010dten\u00ed<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minuty<\/span><\/span>\n<p>Sterilizaci vody lze prov\u00e1d\u011bt r\u016fzn\u00fdmi zp\u016fsoby. Nejbezpe\u010dn\u011bj\u0161\u00edm a nejjednodu\u0161\u0161\u00edm \u0159e\u0161en\u00edm je oza\u0159ov\u00e1n\u00ed UV-C z\u00e1\u0159en\u00edm (vlnov\u00e1 d\u00e9lka 200 ... 280 nm). Tato metoda se pou\u017e\u00edv\u00e1 v laborato\u0159\u00edch, na klinik\u00e1ch, v pr\u016fmyslu, v akv\u00e1ri\u00edch i v dom\u00e1cnostech. Mikroorganismy, jako jsou bakterie, viry, kvasinky a pl\u00edsn\u011b, jsou usmrceny 99,9 % p\u0159i vhodn\u00e9m pr\u016ftoku za jednotku \u010dasu a intenzit\u011b oza\u0159ov\u00e1n\u00ed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Studien\"><\/span>Studie<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Mezi odborn\u00edky na vodu je ob\u010das p\u0159edm\u011btem pochybn\u00fdch debat \u010di\u0159en\u00ed UV-C, pokud jde o inaktivaci vir\u016f. Argumentuje se t\u00edm, \u017ee viry jsou men\u0161\u00ed ne\u017e bakterie a UV-C by je neaktivovalo.<\/p>\n\n\n\n<p>Na str\u00e1nk\u00e1ch <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0043135424012211?via%3Dihub#bib0050\" target=\"_blank\" rel=\"noreferrer noopener\">Studijn\u00ed situace<\/a> To v\u0161ak potvrzuje inaktivaci i vir\u016f, samoz\u0159ejm\u011b v\u017edy v z\u00e1vislosti na d\u00e1vkov\u00e9m p\u0159\u00edkonu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Die_Theorie_%E2%80%A6\"><\/span>Teorie ...<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Sterilizace v\u0161ak nen\u00ed synonymem pro sterilizaci. <a href=\"https:\/\/csiag.eu\/cs\/reverzni-osmoza\/\" data-type=\"post\" data-id=\"2131\">Filtrov\u00e1n\u00ed<\/a>. Kontaminuj\u00edc\u00ed \u010d\u00e1stice odstran\u00ed pouze vhodn\u00e9 filtry! Zne\u010di\u0161t\u011bn\u00e1 voda tak\u00e9 sni\u017euje propustnost UV-C z\u00e1\u0159en\u00ed, a t\u00edm i jeho \u00fa\u010dinnost.<br>Nap\u0159\u00edklad ultra\u010dist\u00e1 voda ve vzd\u00e1lenosti 1 cm od zdroje z\u00e1\u0159en\u00ed (co\u017e odpov\u00edd\u00e1 80 % 100 % z\u00e1\u0159iv\u00e9ho v\u00fdkonu, po 17 mm st\u00e1le 70 %) m\u00e1 propustnost 99 ... 100 %, pitn\u00e1 voda 85 ... 98 %, de\u0161\u0165ov\u00e1 voda 75 ... 85 % a odpadn\u00ed voda 50 ... 75 %.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Strahlungs-Dosis\"><\/span>D\u00e1vka z\u00e1\u0159en\u00ed<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>D\u00e1vka z\u00e1\u0159en\u00ed se vypo\u010d\u00edt\u00e1 z \u010dasu (<em>t<\/em>) vyn\u00e1sobeno intenzitou (<em>I<\/em>) UV-C lampy a vyjad\u0159uje se v mJ\/cm.<sup>2<\/sup> m\u011b\u0159eno.<\/p>\n\n\n\n<p>D\u00e1vka pot\u0159ebn\u00e1 k usmrcen\u00ed mikroorganism\u016f je nap\u0159. pro<\/p>\n\n\n\n\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Patogen<\/th><th class=\"column-2\">D\u00e1vka mJ\/cm2<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Clostridium tetani<\/td><td class=\"column-2\">4,90<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Hepatitida A<\/td><td class=\"column-2\">11,00<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Infek\u010dn\u00ed nekr\u00f3za pankreatu<\/td><td class=\"column-2\">60,00 *<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Klebsiella pneumoniae<\/td><td class=\"column-2\">11,00<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Legionella pneumophilla<\/td><td class=\"column-2\">2,04<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Poliovirus<\/td><td class=\"column-2\">12,00<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Pseudomonas aeruginosa<\/td><td class=\"column-2\">11,00<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Rotavirus<\/td><td class=\"column-2\">35,00<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Saccharomyces cerevisiae<\/td><td class=\"column-2\">6,00<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Salmonella thyphi<\/td><td class=\"column-2\">14,00<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Salmonella thyphimurium<\/td><td class=\"column-2\">13,00<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Spory bac. subtilis<\/td><td class=\"column-2\">12,00<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Staphylococcus aureus<\/td><td class=\"column-2\">36,00<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Streptococcus faecalis<\/td><td class=\"column-2\">4,50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache -->\n\n\n\n<p>Specifikace d\u00e1vek pro p\u0159\u00edstroje se zpravidla ud\u00e1vaj\u00ed v J\/m.<sup>2<\/sup> nebo mJ\/cm<sup>2<\/sup> uvedeno. Vztahuj\u00ed se na p\u0159\u00edslu\u0161n\u00fd pr\u016ftok s ohledem na ur\u010denou \u00fa\u010dinnost nejm\u00e9n\u011b 90% zab\u00edjej\u00edc\u00ed bakterie a viry.<\/p>\n\n\n\n<p>*Hodnoty nad 40 mJ\/cm<sup>2<\/sup> vy\u017eaduj\u00ed pou\u017eit\u00ed druh\u00e9ho ekvivalentn\u00edho stupn\u011b pro pr\u016ftoky nad 4 ... 7 litr\u016f\/min. vy\u017eaduj\u00ed pou\u017eit\u00ed druh\u00e9ho ekvivalentn\u00edho stupn\u011b, aby bylo mo\u017en\u00e9 spolehliv\u011b detekovat tyto patogeny s ohledem na mo\u017enou fotoreaktivaci fotol\u00fdzami. Tyto enzymy mohou opravit po\u0161kozen\u00ed bun\u011bk v DNA zp\u016fsoben\u00e9 sv\u011btlem UV-C. Aby se tomuto \u00fa\u010dinku \u00fa\u010dinn\u011b zabr\u00e1nilo, je t\u0159eba pou\u017e\u00edt d\u00e1vky p\u0159ibli\u017en\u011b 44 mJ\/cm<sup>2<\/sup>nebo 440 J\/m<sup>2<\/sup> po\u017eadov\u00e1no.<\/p>\n\n\n\n<p>Sn\u00ed\u017een\u00ed pr\u016ftoku na polovinu m\u00e1 za n\u00e1sledek zdvojn\u00e1soben\u00ed d\u00e1vky, co\u017e n\u00e1sledn\u011b zv\u00fd\u0161\u00ed dezinfek\u010dn\u00ed v\u00fdkon desetin\u00e1sobn\u011b. 90procentn\u00ed dezinfekce pak stoupne na 99 %. Trojn\u00e1sobn\u00e9 zv\u00fd\u0161en\u00ed d\u00e1vky vede ke sterilizaci 99,9 %.<\/p>\n\n\n\n<p>To znamen\u00e1, \u017ee v\u00fd\u0161e uveden\u00e1 fotoreaktivace p\u0159i polovi\u010dn\u00edm pr\u016ftoku je ji\u017e zohledn\u011bna jednou jednotkou.<br>Pokud v\u0161ak hodl\u00e1te sterilizovat vysoce zne\u010di\u0161t\u011bnou vodu a vy\u017eadujete vy\u0161\u0161\u00ed pr\u016ftok, doporu\u010dujeme pou\u017e\u00edt druh\u00fd a p\u0159\u00edpadn\u011b t\u0159et\u00ed stupe\u0148.<br><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"%E2%80%A6_und_die_Praxis\"><\/span>... a praxe<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Tlakov\u00e1 \u010derpadla instalovan\u00e1 v obytn\u00fdch automobilech, nap\u0159. <a href=\"https:\/\/www.amazon.de\/Shurflo-Wasser-Camper-Liter-Armaturen\/dp\/B07DYS5XZJ\/ref=sr_1_1?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=22S8P4PJDEWEW&amp;keywords=shurflo+2095-204-112&amp;qid=1655889462&amp;sprefix=shurflo+2095-204-112%2Caps%2C123&amp;sr=8-1\" target=\"_blank\" rel=\"noreferrer noopener\">Shurflo<\/a>\u010derp\u00e1n\u00ed a\u017e 7 litr\u016f\/min. Jeden <a href=\"https:\/\/www.purion.de\/produkte\/purion-500\/\" target=\"_blank\" rel=\"noreferrer noopener\">Purway 500<\/a> Dezinfek\u010dn\u00ed syst\u00e9m UV-C (12 nebo 24 V DC) je vhodn\u00fd a\u017e pro 400 litr\u016f\/h p\u0159i 400 J\/m.<sup>2<\/sup> a pracuje p\u0159i vlnov\u00e9 d\u00e9lce 254 nm s UVT (<em>P\u0159enos UV z\u00e1\u0159en\u00ed<\/em>) 90 %. Pr\u016ftok je 6,7 litru za minutu. Vzhledem k mal\u00fdm pr\u016f\u0159ez\u016fm potrub\u00ed 10 ... 12 mm dod\u00e1v\u00e1 syst\u00e9m Purway maxim\u00e1ln\u011b 1,1 l\/min. V\u00fdsledkem je d\u00e1vka 6 666,67 J\/m p\u0159i pr\u016ftoku p\u0159ibli\u017en\u011b 60 litr\u016f za hodinu.<sup>2<\/sup> a \u00fa\u010dinnost 99,999999999999 % (odpov\u00edd\u00e1 log12)!<\/p>\n\n\n\n<p>Doporu\u010duje se instalovat syst\u00e9m s tzv. monitorovac\u00ed jednotkou. Ta upozorn\u00ed na dosa\u017een\u00ed \u017eivotnosti lampy, aby byl zaji\u0161t\u011bn trvale vysok\u00fd steriliza\u010dn\u00ed v\u00fdkon.<br>Je t\u0159eba poznamenat, \u017ee d\u00e1vkov\u00fd p\u0159\u00edkon lampy s \u010dasem kles\u00e1. Proto by m\u011bl b\u00fdt bu\u010f celkov\u00fd d\u00e1vkov\u00fd p\u0159\u00edkon odpov\u00eddaj\u00edc\u00edm zp\u016fsobem naddimenzov\u00e1n, nebo by m\u011bl b\u00fdt napl\u00e1nov\u00e1n rychlej\u0161\u00ed interval v\u00fdm\u011bny lampy.<br>Alternativn\u011b lze nainstalovat po\u010d\u00edtadlo provozn\u00edch hodin, pokud byl zakoupen syst\u00e9m bez monitorovac\u00ed jednotky.<\/p>\n\n\n\n<p>Doporu\u010dujeme tak\u00e9 objednat n\u00e1hradn\u00ed lampu UV-C. Nen\u00ed to ani tak s ohledem na p\u0159edpokl\u00e1danou \u017eivotnost, ale sp\u00ed\u0161e proto, \u017ee podle Murphyho z\u00e1kon\u016f je velmi pravd\u011bpodobn\u00e9, \u017ee dojde k jej\u00edmu p\u0159ed\u010dasn\u00e9mu selh\u00e1n\u00ed v nejhor\u0161\u00ed mo\u017enou dobu, daleko od dodavatele p\u0159\u00edslu\u0161n\u00e9ho n\u00e1hradn\u00edho d\u00edlu ...<br><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wahl_des_Einbauortes\"><\/span>Volba m\u00edsta instalace<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ve spr\u0161e ani v koupeln\u011b nebudete pot\u0159ebovat vodu bez bakteri\u00ed. Budete ji v\u0161ak pot\u0159ebovat v kuchyni. Ide\u00e1ln\u00ed je proto potrub\u00ed studen\u00e9 vody t\u011bsn\u011b p\u0159ed odb\u011brn\u00fdm m\u00edstem. Na zadn\u00ed st\u011bn\u011b d\u0159ezov\u00e9 sk\u0159\u00ed\u0148ky je obvykle dostatek m\u00edsta pro integraci 32 cm dlouh\u00e9 UV jednotky do vodovodn\u00ed hadice.<\/p>\n\n\n\n<p>Krom\u011b dvou vhodn\u00fdch hadicov\u00fdch trysek s hadicov\u00fdmi svorkami pot\u0159ebujete tak\u00e9 p\u0159\u00edpojku 12\/24 V DC. K tomu se hod\u00ed vodn\u00ed \u010derpadlo. Pokud je sac\u00ed \u010derpadlo aktivov\u00e1no p\u0159es vodovodn\u00ed kohoutek, posta\u010d\u00ed dvou\u017eilov\u00fd kabel polo\u017een\u00fd pod\u00e9l vodn\u00edch hadic ve sm\u011bru \u010derpadla a p\u0159ipojen\u00fd tam paraleln\u011b k jeho nap\u00e1jen\u00ed.<br><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Besonderheit_Druckpumpe\"><\/span>Speci\u00e1ln\u00ed funkce tlakov\u00e9ho \u010derpadla<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>U p\u0159eru\u0161ovan\u011b b\u011b\u017e\u00edc\u00edch tlakov\u00fdch \u010derpadel je t\u0159eba paraleln\u011b instalovat zpo\u017e\u010fovac\u00ed obvod, kter\u00fd n\u00e1sledn\u011b p\u0159evezme nap\u00e1jen\u00ed steriliza\u010dn\u00edho syst\u00e9mu tak, aby z\u016fstal zapnut\u00fd po nastavitelnou dobu i po vypnut\u00ed tlakov\u00e9ho \u010derpadla a pokra\u010doval odb\u011br vody.<br><br>Toho je dosa\u017eeno pomoc\u00ed <a href=\"https:\/\/www.amazon.de\/dp\/B07W6NLTYT\/ref=pe_27091401_487024491_TE_item\" target=\"_blank\" rel=\"noreferrer noopener\">\u0158\u00eddic\u00ed elektronika<\/a>kter\u00e1 zpozd\u00ed vypnut\u00ed nap\u00e1jec\u00edho nap\u011bt\u00ed pro steriliza\u010dn\u00ed syst\u00e9m na nastavitelnou dobu.<br>P\u0159ipojuje se p\u0159\u00edmo k palubn\u00edmu nap\u011bt\u00ed 12 nebo 24 V. Na sign\u00e1ln\u00edm vstupu je kabel p\u0159ipojen paraleln\u011b k odch\u00e1zej\u00edc\u00edmu plusov\u00e9mu vodi\u010di tlakov\u00e9ho sp\u00edna\u010de tlakov\u00e9ho \u010derpadla. P\u0159i spu\u0161t\u011bn\u00ed \u010derpadla se aktivuje kladn\u00e1 hladina, kter\u00e1 zapne tlakov\u00e9 \u010derpadlo, spust\u00ed se \u010dasov\u00e9 zpo\u017ed\u011bn\u00ed a dezinfek\u010dn\u00ed syst\u00e9m z\u016fstane zapnut\u00fd po nastavenou dobu.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>p.s. Pokud pot\u0159ebujete osobn\u00ed podporu p\u0159i realizaci za \u00faplatu, m\u016f\u017eete zaslat&nbsp;<a href=\"https:\/\/csiag.eu\/cs\/poradenske-sluzby\/\">Rezervace<\/a>&nbsp;vyrobit!<\/p>\n<\/blockquote>\n\n\n\n<p><br><br><\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Doba \u010dten\u00ed<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minuty<\/span><\/span>Sterilizaci vody lze prov\u00e1d\u011bt r\u016fzn\u00fdmi zp\u016fsoby. Nejbezpe\u010dn\u011bj\u0161\u00edm a nejjednodu\u0161\u0161\u00edm \u0159e\u0161en\u00edm je oza\u0159ov\u00e1n\u00ed UV-C z\u00e1\u0159en\u00edm (vlnov\u00e1 d\u00e9lka 200 ... 280 nm). Tato metoda se pou\u017e\u00edv\u00e1 v laborato\u0159\u00edch, na klinik\u00e1ch, v pr\u016fmyslu, v akv\u00e1ri\u00edch i v dom\u00e1cnostech. Mikroorganismy, jako jsou bakterie, viry, kvasinky a pl\u00edsn\u011b, jsou usmrceny 99,9 % p\u0159i vhodn\u00e9m pr\u016ftoku za jednotku \u010dasu a intenzit\u011b oza\u0159ov\u00e1n\u00ed. Studie v r\u00e1mci...&nbsp;<a href=\"https:\/\/csiag.eu\/cs\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/\" rel=\"bookmark\">\u010c\u00edst d\u00e1le \"<span class=\"screen-reader-text\">Sterilizace vody pomoc\u00ed UV-C<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[340,338],"tags":[680,691,684,687,618,591,688,693,679,696,694,697,695,686,698,689,690,699,685,683,682,681,677,678,676,692],"class_list":["post-1912","post","type-post","status-publish","format-standard","hentry","category-wasser-entkeimung-mittels-uv-c","category-wasser-management","tag-bestrahlungsintensitaet","tag-dna","tag-dosis","tag-dosis-angaben","tag-druckpumpe","tag-durchflussmenge","tag-durchflussraten","tag-entkeimungs-kapazitaet","tag-filterung","tag-filterwechsel","tag-fliessgeschwindigkeit","tag-kalk","tag-lampenlebensdauer","tag-mikroorganismen","tag-pha","tag-photolyasen","tag-photoreaktivierung","tag-polyphosphat","tag-strahlungs-dosis","tag-strahlungsleistung","tag-strahlungsquelle","tag-transmission","tag-uv-c","tag-v-c-klaerer","tag-wasser-entkeimung","tag-zellschaden"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/posts\/1912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/comments?post=1912"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/posts\/1912\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/media?parent=1912"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/categories?post=1912"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/cs\/wp-json\/wp\/v2\/tags?post=1912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}