{"id":10071,"date":"2025-06-17T10:30:00","date_gmt":"2025-06-17T10:30:00","guid":{"rendered":"https:\/\/csiag.eu\/?p=10071"},"modified":"2025-06-18T15:46:20","modified_gmt":"2025-06-18T15:46:20","slug":"hvorfor-har-du-brug-for-relaeer","status":"publish","type":"post","link":"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/","title":{"rendered":"Hvorfor har du brug for rel\u00e6er?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Indholdsfortegnelse<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Kabelquerschnitt\" >Tv\u00e6rsnit af kabel<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Relais-Arten\" >Rel\u00e6-typer<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Schlieser-_Offner\" >Normalt \u00e5ben \/ normalt lukket kontakt<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Wechsler\" >Skifter<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Sonderrelais\" >S\u00e6rligt rel\u00e6<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Praxis-Beispiel\" >Praktisk eksempel<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>\n<p class=\"wp-block-paragraph\">Rel\u00e6er bruges til at skifte forbrugere (belastninger) med h\u00f8jere effekt (W - Watt -). <em>P<\/em>), end afbryderens kontakt eller kabeltv\u00e6rsnittet ved afbryderen tillader.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alle kender det rytmiske klik fra blinklysrel\u00e6et i en bil. Et integreret elektronisk system s\u00f8rger for det lovpligtige blinkinterval og t\u00e6nder og slukker for rel\u00e6et. De blinklys, der er tilsluttet rel\u00e6et og forsynes med sp\u00e6nding via rel\u00e6et, blinker med samme hastighed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nu har indikatorer ikke brug for meget str\u00f8m, de flyder ikke h\u00f8je str\u00f8mme, men det er en helt anden historie med k\u00f8relamper!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Kabelquerschnitt\"><\/span>Tv\u00e6rsnit af kabel<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">I sidste ende kan selv mindre <a href=\"https:\/\/csiag.eu\/da\/elektrisk-installation-i-en-autocamper-er-ikke-heksekunst\/#Kabelquerschnitt\" data-type=\"post\" data-id=\"6364\" target=\"_blank\" rel=\"noreferrer noopener\">Tv\u00e6rsnit af kabler<\/a> (her kan kabeltv\u00e6rsnit i DC-sp\u00e6ndingsomr\u00e5det bestemmes) mellem kontakten og rel\u00e6et, hvilket reducerer omkostningerne og gavner de st\u00f8rre tv\u00e6rsnit fra rel\u00e6et til belastningen. Disse kabler kan holdes korte, hvilket igen holder omkostningerne og sp\u00e6ndingsfaldene p\u00e5 kabelstien lave.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis kablerne er for tynde til den n\u00f8dvendige effekt, bliver de varme og kan blive til en varmetr\u00e5d. Tynde kabler har en h\u00f8j ohmsk modstand (\u03a9 (Ohm)-modstand). <em>R<\/em>), hvilket f\u00f8rer til mindre sp\u00e6nding i slutningen end i begyndelsen.<br>En kabelrulle med 50 m og et kabeltv\u00e6rsnit p\u00e5 3 x 1,5 mm<sup>2<\/sup> forsyner en belastning med 16 ampere (A - str\u00f8mstyrke <em>I<\/em>) er stadig kun 210 volt (V - sp\u00e6nding -). <em>U<\/em>). Hvis du bruger et kabel med 3x 2,5 mm i stedet<sup>2<\/sup>er du stadig p\u00e5 221 V.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Campister konfronteres ofte med dette problem, idet de medbringer lange kabelruller og senere klager over det h\u00f8je str\u00f8mforbrug eller reagerende afbrydere, mens alt fungerede perfekt derhjemme - med et kort kabel ...!<br>Det skyldes, at en belastning tr\u00e6kker mere str\u00f8m, hvis den f\u00e5r for lidt sp\u00e6nding til at levere sin effekt. Derfor er str\u00f8mforbruget h\u00f8jere, n\u00e5r sp\u00e6ndingen er lavere end \"normalt\".<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kabeltv\u00e6rsnit i vekselsp\u00e6ndingsomr\u00e5det - AC - kan bruges i denne <a href=\"https:\/\/csiag.eu\/da\/hvad-du-skal-gore-i-tilfaelde-af-stromsvigt\/#Kabelquerschnitt_AC\" data-type=\"post\" data-id=\"1418\" target=\"_blank\" rel=\"noreferrer noopener\">Bord<\/a> beregnes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Relais-Arten\"><\/span>Rel\u00e6-typer<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">I k\u00f8ret\u00f8jskonstruktioner er der normalt rel\u00e6er, der drives med 12 eller 24 V j\u00e6vnsp\u00e6nding (DC), og som kan skifte belastninger p\u00e5 op til ca. 30 A. Effektrel\u00e6er kan ogs\u00e5 h\u00e5ndtere op til 400 A.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rel\u00e6spolernes tilslutninger er m\u00e6rket 85 og 86. For rel\u00e6er med en indbygget gnistd\u00e6mpningsdiode er 86 tildelt plus. Rel\u00e6er uden gnistslukningsdiode kan tilsluttes med enhver polaritet, men det har vist sig at v\u00e6re en god id\u00e9 at v\u00e6lge polariteten, som om der var installeret en gnistslukningsdiode (i elektronikken kaldes dette for <em>Fritl\u00f8bende diode<\/em>). P\u00e5 denne m\u00e5de kan et rel\u00e6 med en hvilken som helst konfiguration bruges i den samme stikd\u00e5se uden at blive beskadiget af forkert polaritet. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Schlieser-_Offner\"><\/span>Normalt \u00e5ben \/ normalt lukket kontakt<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Rel\u00e6er til at sl\u00e5 en belastning til har en NO-kontakt, og en NC-kontakt til at sl\u00e5 den fra. Kontakten p\u00e5 et normalt \u00e5bent rel\u00e6 er derfor \u00e5ben i sp\u00e6ndingsl\u00f8s tilstand og lukker, s\u00e5 snart rel\u00e6et forsynes med sp\u00e6nding. NC-kontakten fungerer omvendt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Koblingskontakterne er m\u00e6rket 30 (plus) og 87 (minus).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"587\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-587x1024.png\" alt=\"\" class=\"wp-image-10072\" style=\"width:159px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-587x1024.png 587w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-172x300.png 172w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-7x12.png 7w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5.png 659w\" sizes=\"(max-width: 587px) 100vw, 587px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Gnistslukningsdioden under rel\u00e6spolen har til opgave at absorbere og kompensere for sp\u00e6ndingstoppe p\u00e5 flere hundrede volt, der opst\u00e5r i spolen, n\u00e5r str\u00f8mforsyningen til rel\u00e6et slukkes.<br>Selv om de fleste rel\u00e6er, der bruges i bilindustrien, ikke har et s\u00e5dant beskyttelseskredsl\u00f8b integreret, fordi rel\u00e6spolerne er ret \"robuste\", er det en klogere beslutning at bruge rel\u00e6er med en integreret gnistundertrykkelsesdiode, hvis det er muligt!<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wechsler\"><\/span>Skifter<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Omskifterel\u00e6et g\u00f8r det muligt at skifte mellem to belastninger og har derfor tre skiftekontakter og dermed ogs\u00e5 tre tilslutninger, 30 (positiv), 87 (NO) og 87a (NC).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"504\" height=\"954\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6.png\" alt=\"\" class=\"wp-image-10073\" style=\"width:161px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6.png 504w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6-158x300.png 158w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6-6x12.png 6w\" sizes=\"(max-width: 504px) 100vw, 504px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sonderrelais\"><\/span>S\u00e6rligt rel\u00e6<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Det kan v\u00e6re blink- eller timerrel\u00e6er med integreret elektronik.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Praxis-Beispiel\"><\/span>Praktisk eksempel<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00e5let er at kunne t\u00e6nde og slukke for flere belastninger centralt via et kontaktpanel. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Forhandlerne tilbyder en lang r\u00e6kke produkter, som alle har \u00e9n ting til f\u00e6lles: Kablerne er meget tynde og kun beregnet til lave str\u00f8mme. Vi husker: kobber er dyrt ...<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"570\" height=\"299\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8.png\" alt=\"\" class=\"wp-image-10075\" style=\"width:466px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8.png 570w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8-300x157.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8-18x9.png 18w\" sizes=\"(max-width: 570px) 100vw, 570px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Det, der starter med en lille LED-lampe, vokser til et helt belysningssystem hurtigere end forventet. Det \u00f8ger ogs\u00e5 effektbehovet og dermed den effekt, der skal skiftes. En sag for brug af et rel\u00e6.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ledningerne til disse kontakter er normalt broforbundne: alle positive og negative poler er forbundet med hinanden. Den belastning, der er tilsluttet via den sidste kontakt, tr\u00e6kker sin str\u00f8m via alle tidligere broer. Det betyder, at summen af str\u00f8mmen fra alle tilsluttede belastninger ikke m\u00e5 overstige forsyningsledningens kapacitet.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"395\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-1024x395.png\" alt=\"\" class=\"wp-image-10085\" style=\"width:513px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-1024x395.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-300x116.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-768x296.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-18x7.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16.png 1126w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">De 12 V 20 A, der normalt angives af producenten, refererer faktisk kun til standardkabell\u00e6ngden p\u00e5 nogle f\u00e5 centimeter. Hvis der kun medregnes EN meter forsyningskabel, er den tilladte str\u00f8m kun 2 A, en tiendedel!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I den forbindelse er brugen af koblingsrel\u00e6er (normalt \u00e5bne kontakter) derfor mere end anbefalelsesv\u00e6rdig.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den frie kontakt m\u00e6rket \"V\" f\u00f8rer til tilslutningen 86 p\u00e5 et rel\u00e6, ledningen m\u00e6rket \"-\" er forbundet til terminal 85.<br>Forbrugeren tr\u00e6kker sin jord (minus) direkte fra batteriet (eller k\u00f8ret\u00f8jets jordforbindelse), mens den modtager plus via den koblede rel\u00e6forbindelse 87.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"857\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-1024x857.png\" alt=\"\" class=\"wp-image-10083\" style=\"width:517px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-1024x857.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-300x251.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-768x643.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-1536x1286.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-14x12.png 14w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14.png 2034w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Hvis den tilh\u00f8rende kontakt nu aktiveres, modtager rel\u00e6et plus p\u00e5 kontakt 86, henter og skifter via sin kontakt (30 - plus) til den modsatte kontakt 87, hvorefter belastningen ogs\u00e5 modtager plus og derfor er t\u00e6ndt. S\u00e5 snart kontakten slukkes igen, falder rel\u00e6et ud og afbryder str\u00f8mforsyningen til belastningen.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>Rel\u00e6er bruges til at skifte belastninger med h\u00f8jere effekt (W - Watt - P), end afbryderens kontakt eller kabeltv\u00e6rsnittet ved afbryderen ville tillade. Alle kender det rytmiske klik fra blinklysrel\u00e6et i en bil. Et integreret elektronisk system sikrer det lovm\u00e6ssigt foreskrevne blinkinterval og t\u00e6nder og slukker for rel\u00e6et. I samme cyklus...&nbsp;<a href=\"https:\/\/csiag.eu\/da\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/\" rel=\"bookmark\">L\u00e6s mere \"<span class=\"screen-reader-text\">Hvorfor har du brug for rel\u00e6er?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2588,5081],"tags":[2382,2384,5084,5085,5087,2881,4474,5090,5089,1432,1060,5092,5088,5093,5082,2882,5097,1280,5083,5095,1062,981,448,459,446,642,444,466,1415,1378,5094,5091,5096],"class_list":["post-10071","post","type-post","status-publish","format-standard","hentry","category-kfz-technik","category-relais-technik","tag-12v","tag-24v","tag-5084","tag-5085","tag-5087","tag-ampere","tag-blinker-relais","tag-freilaufdiode","tag-funkenloeschdiode","tag-gleichspannung","tag-kabelquerschnitt","tag-kabelrolle","tag-last","tag-leistungsrelais","tag-oeffner","tag-ohm","tag-polung","tag-relais","tag-schliesser","tag-schutzschaltung","tag-sicherung","tag-sicherungsautomat","tag-spannung","tag-spannungsabfall","tag-strom","tag-stromstaerke","tag-stromverbrauch","tag-verbraucher","tag-volt","tag-watt","tag-wechsler","tag-widerstand","tag-zeitrelais"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/10071","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/comments?post=10071"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/10071\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/media?parent=10071"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/categories?post=10071"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/tags?post=10071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}