{"id":3126,"date":"2023-01-12T10:01:59","date_gmt":"2023-01-12T10:01:59","guid":{"rendered":"https:\/\/csiag.eu\/?p=3126"},"modified":"2023-09-05T11:16:02","modified_gmt":"2023-09-05T11:16:02","slug":"fotovoltaik","status":"publish","type":"post","link":"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/","title":{"rendered":"Fotovoltaik"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Indholdsfortegnelse<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Rechtslage_zum_01012021\" >Juridisk situation pr. 01.01.2021<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Vergutung_fur_eingespeisten_Strom\" >Vederlag for elektricitet, der leveres til nettet<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Auswahl_der_PV-Module\" >Valg af solcellemoduler<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Kleines_Wechselrichter_1%C3%971\" >Lille inverter 1\u00d71<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Technische_Wechselrichter-Details\" >Tekniske detaljer om inverteren<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Eingangsphasen\" >Input-faser<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#AC_Nennleistung\" >Nominel AC-effekt<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Anzahl_MPP_Tracker\" >Antal MPP-trackere<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#MPP_Bereich\" >MPP-omr\u00e5de<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Eingangsstrom\" >Indgangsstr\u00f8m<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Leerlaufspannung\" >Sp\u00e6nding i \u00e5bent kredsl\u00f8b<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/#Wirkungsgrad\" >Effektivitet<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rechtslage_zum_01012021\"><\/span>Juridisk situation pr. 01.01.2021<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Den nye lov om vedvarende energikilder (EEG) tr\u00e5dte i kraft den 1. januar 2021, ogs\u00e5 for solcelleanl\u00e6g.<\/p>\n\n\n\n<p>Det betyder, at egetforbrug fra gamle og nye solcelleanl\u00e6g op til og med 30 kWp er fritaget for EEG-till\u00e6gget. Det er ikke n\u00f8dvendigt at installere intelligente m\u00e5lere til dataindsamling for egetforbrug op til 7 kWp.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Vergutung_fur_eingespeisten_Strom\"><\/span>Vederlag for elektricitet, der leveres til nettet<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Indf\u00f8dningstariffen falder med stigende produktion og stigende dato for f\u00f8rste idrifts\u00e6ttelse. Det betyder, at jo mere systemet leverer, og jo senere det installeres, jo lavere er feed-in-tariffen.<\/p>\n\n\n\n<p>Systemer, der s\u00e6ttes i drift den 1. september 2021, vil blive godtgjort med 0,0725 euro for op til 10 kWp. Med 0,30 ... 0,35 euro pr. kWh for indk\u00f8bt elektricitet udg\u00f8r vederlaget ca. 20% af den pris, der skal betales for indk\u00f8bt elektricitet. Alle kan selv afg\u00f8re, om det kan betale sig at levere str\u00f8m til nettet.<\/p>\n\n\n\n<p>Det giver m\u00e5ske mere mening at bruge den komplette <a href=\"https:\/\/csiag.eu\/da\/oekonomisches-energiemanagement\/#Zuviel\" rel=\"sponsored nofollow\">Eget forbrug<\/a> v\u00e6re.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Auswahl_der_PV-Module\"><\/span>Valg af solcellemoduler<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Hvor solcellemoduler tidligere var mange gange dyrere og langt mindre effektive, findes der i dag et enormt udvalg af design, output, effektivitet osv.<\/p>\n\n\n\n<p>Det er ikke let at finde den gyldne middelvej, men det kan lade sig g\u00f8re.<\/p>\n\n\n\n<p>V\u00e6lg en anerkendt producent, et design, der kr\u00e6ver f\u00e5 moduler, giver den h\u00f8jest mulige effektivitet og kommer s\u00e5 t\u00e6t som muligt p\u00e5 det \u00f8nskede output.<\/p>\n\n\n\n<p>Designet er normalt rektangul\u00e6rt, men varierer i modulernes bredde og l\u00e6ngde. Det tilg\u00e6ngelige areal er derfor den begr\u00e6nsende faktor, n\u00e5r modulst\u00f8rrelsen skal v\u00e6lges. Hvis der bygges flere r\u00e6kker, skal der tages h\u00f8jde for skyggen fra modulerne bag den f\u00f8rste r\u00e6kke. Man skal planl\u00e6gge en tilsvarende afstand mellem modulr\u00e6kkerne, s\u00e5 der ikke kastes skygger p\u00e5 den n\u00e6ste r\u00e6kke, n\u00e5r solen st\u00e5r lavere. Det minimerer det anvendelige areal.<\/p>\n\n\n\n<p>De n\u00f8dvendige afstande kan bestemmes ved hj\u00e6lp af software eller mere simpelt ved at tegne.<\/p>\n\n\n\n<p>De data, der kr\u00e6ves til dette, er:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Geogr. l\u00e6ngde\/bredde af installationsstedet<\/li>\n\n\n\n<li>Solens azimut ved vintersolhverv 12:00 h<\/li>\n\n\n\n<li>Elevationsh\u00f8jde p\u00e5 modulets \u00f8verste kant<\/li>\n\n\n\n<li>Elevationsvinkel (normalt 30\u00b0)<\/li>\n<\/ul>\n\n\n\n<p>En god dokumentation af dette kan findes i dette v\u00e6rk af <a href=\"https:\/\/www.volker-quaschning.de\/downloads\/staffelstein1998_1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Dr.-Ing. Volker Quaschning og Prof. Dr.-Ing. habil. Rolf Hanitsch<\/a>. Som det normalt er tilf\u00e6ldet, er et optimalt resultat altid forbundet med en indsats, om ikke andet s\u00e5 i form af at s\u00e6tte sig ind i de teoretiske overvejelser, der ligger til grund for det.<\/p>\n\n\n\n<p>N\u00e5r de givne parametre er fastlagt, er n\u00e6ste skridt at finde de rigtige moduler. Til maksimalt 7 kW er 20 moduler p\u00e5 hver 350 W velegnede, som kan forbindes i 2 strenge p\u00e5 hver 10 moduler.<br>En streng refererer til en serieforbindelse af moduler. En eksemplarisk modul-MPP-sp\u00e6nding (Maximum Power Point) p\u00e5 35 V resulterer i en inverterindgangssp\u00e6nding p\u00e5 350 V DC. <\/p>\n\n\n\n<p>Antallet af mulige strenge afh\u00e6nger af valget af inverter. Sm\u00e5 invertere har kun en MPP-tracker og tillader derfor kun tilslutning af en enkelt streng.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Kleines_Wechselrichter_1%C3%971\"><\/span>Lille inverter 1\u00d71<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Der er grundl\u00e6ggende tre typer invertere, dem, der er nettilsluttede eller off-grid, eller en kombination af begge driftstilstande.<\/p>\n\n\n\n<p><em>Netv\u00e6rksstyret<\/em> Invertere synkroniserer sig selv med 50 Hz-netfrekvensen. Hvis dette mislykkes i tilf\u00e6lde af str\u00f8msvigt, holder de op med at arbejde, s\u00e5 l\u00e6nge str\u00f8msvigtet varer.<\/p>\n\n\n\n<p><em>Netv\u00e6rksuafh\u00e6ngig<\/em> Invertere bruges i s\u00e5kaldte stand-alone-systemer, dvs. uafh\u00e6ngige solcelleanl\u00e6g, der ikke er koblet til det offentlige net.<\/p>\n\n\n\n<p>Invertere, der kombinerer begge driftstilstande, kaldes <em>Hybrid<\/em>-P\u00e5 den ene side er de forbundet til det offentlige net, men ogs\u00e5 via s\u00e5kaldte MPPT-controllere til batterier, der oplades af de solcellemoduler, der ogs\u00e5 er tilsluttet, n\u00e5r solen skinner. I tilf\u00e6lde af netsvigt skifter hybridinverteren simpelthen til batteridrift og opretholder dermed str\u00f8mforsyningen inden for dens belastningsgr\u00e6nser. N\u00e5r det offentlige net er tilg\u00e6ngeligt igen, skifter den til batteriopladning.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Technische_Wechselrichter-Details\"><\/span>Tekniske detaljer om inverteren<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>En trefaset enhed kan v\u00e6lges som inverter, f.eks. en Kostal Piko IQ 8.5 til lige under 2.000 euro. Enfasede enheder f\u00e5s kun op til 5 kW, f.eks. Kostal Piko MP plus 5.0-2 til ca. 1.200 euro.<\/p>\n\n\n\n<p>Begge enheder har hver to MPP-trackere (tilslutning af to strenge).<\/p>\n\n\n\n<p>Hvilke data er relevante, n\u00e5r man skal v\u00e6lge en inverter?<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Eingangsphasen\"><\/span>Input-faser<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Mindre invertere op til ca. 5 kW tilbyder generelt en fase, st\u00f8rre invertere tre faser. Der kr\u00e6ves et trelederkabel til nettilslutningen for en enfaset tilslutning og et femlederkabel for en trefaset tilslutning.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"AC_Nennleistung\"><\/span>Nominel AC-effekt<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Den nominelle AC-effekt er inverterens maksimale effekt og derfor ogs\u00e5 den h\u00f8jeste PV-effekt, der kan installeres. Det betyder, at der ikke m\u00e5 tilsluttes flere solcellemoduler til en inverter end dens nominelle AC-effekt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Anzahl_MPP_Tracker\"><\/span>Antal MPP-trackere<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Antallet af MPP-trackere, der er tilg\u00e6ngelige p\u00e5 en inverter, bestemmer antallet af strenge, der kan tilsluttes. Mindre invertere har normalt kun \u00e9n MPP-tracker, mens st\u00f8rre invertere har to eller flere. Jo flere MPP-trackere, der er installeret, jo dyrere er inverterne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"MPP_Bereich\"><\/span>MPP-omr\u00e5de<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Det DC-sp\u00e6ndingsomr\u00e5de, der er angivet her, definerer den maksimalt mulige DC-indgangssp\u00e6nding ved MPP-trackeren. Den samlede DC-sp\u00e6nding for alle moduler kombineret i serie i en streng m\u00e5 ikke overstige den \u00f8vre gr\u00e6nse. Hvis omr\u00e5det er specificeret som 360 ... 600 V, beskrives PV-modulets MPP-sp\u00e6nding som 35 V, hvilket resulterer i 600 \/ 35 = 17,14, dvs. maksimalt 17 moduler er mulige i serie som en streng.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Eingangsstrom\"><\/span>Indgangsstr\u00f8m<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Indgangsstr\u00f8mmen angiver summen af alle strengstr\u00f8mme som f\u00f8lge af additionen af MPP-str\u00f8mmene for et modul i hver streng. Hvis et PV-modul har en MPP-str\u00f8m p\u00e5 9,92 A, og der er installeret to strenge, resulterer 9,92 + 9,92 i en indgangsstr\u00f8m p\u00e5 19,84 A.<br>Hvis vi antager, at inverteren kun kan h\u00e5ndtere maksimalt 16 A, skal der installeres moduler med en maksimal MPP-str\u00f8m p\u00e5 16 - 9,92 = 6,08 A i den anden streng.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leerlaufspannung\"><\/span>Sp\u00e6nding i \u00e5bent kredsl\u00f8b<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Solcellemodulernes tomgangssp\u00e6nding er altid h\u00f8jere end MPP-sp\u00e6ndingen. Den er h\u00f8jere ved lave udetemperaturer og lavere ved h\u00f8je temperaturer. Hvis inverteren angiver en maksimal tomgangssp\u00e6nding p\u00e5 f.eks. 750 V, m\u00e5 modulets tomgangssp\u00e6nding ikke overstige 750 \/ 17 = 44 V med 17 moduler installeret.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wirkungsgrad\"><\/span>Effektivitet<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Virkningsgraden beskriver den effektivitet, hvormed en inverter omdanner den indg\u00e5ende DC-sp\u00e6nding til den udg\u00e5ende AC-sp\u00e6nding. Men da virkningsgraden ogs\u00e5 varierer med svingende solintensitet, er viden om sp\u00e6ndingsafh\u00e6ngigheden vigtig for korrekt design. Som regel er en lavere sp\u00e6nding forbundet med h\u00f8jere effektivitet.<br>I denne sammenh\u00e6ng er det derfor mindre effektivt at bruge den \u00f8verste gr\u00e6nse for MPP-omr\u00e5det. Det er derfor bedre at bruge en konfiguration med flere strenge, selv om det betyder et st\u00f8rre \u00f8konomisk udl\u00e6g ved k\u00f8b af inverteren.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>Juridisk situation pr. 01.01.2021 Den nye EEG (lov om vedvarende energikilder) tr\u00e5dte i kraft den 01.01.2021, ogs\u00e5 for solcelleanl\u00e6g. Det betyder, at egetforbrug fra gamle og nye solcelleanl\u00e6g op til og med 30 kWp er fritaget for EEG-till\u00e6gget. For egetforbrug op til 7 kWp skal der ikke installeres intelligente m\u00e5lere til dataindsamling.&nbsp;<a href=\"https:\/\/csiag.eu\/da\/blog\/2023\/01\/12\/photovoltaik\/\" rel=\"bookmark\">L\u00e6s mere \"<span class=\"screen-reader-text\">Fotovoltaik<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[360,365],"tags":[937,928,927,938,940,799,934,941,447,931,939,935,936,932,933,812,930,926,929,741,446,925,529,644],"class_list":["post-3126","post","type-post","status-publish","format-standard","hentry","category-haus-und-garten","category-photovoltaik-fuer-daheim","tag-batteriebetrieb","tag-eeg-umlage","tag-eigenverbrauch","tag-eingangsphase","tag-eingangsstrom","tag-hybrid-wechselrichter","tag-lastgrenze","tag-leerlaufspannung","tag-leistung","tag-mpp-tracker","tag-nennleistung","tag-netzausfall","tag-netzfrequenz","tag-netzgefuehrt","tag-netzunabhaengig","tag-photovoltaik","tag-pv-modul","tag-rechtslage","tag-smartmeter","tag-string","tag-strom","tag-verguetung","tag-wechselrichter","tag-wirkungsgrad"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/3126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/comments?post=3126"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/3126\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/media?parent=3126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/categories?post=3126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/tags?post=3126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}