{"id":3679,"date":"2023-03-27T15:01:38","date_gmt":"2023-03-27T15:01:38","guid":{"rendered":"https:\/\/csiag.eu\/?p=3679"},"modified":"2023-03-27T16:00:28","modified_gmt":"2023-03-27T16:00:28","slug":"victron-multiplus-ii-inverter-defekt","status":"publish","type":"post","link":"https:\/\/csiag.eu\/da\/blog\/2023\/03\/27\/victron-multiplus-ii-inverter-defekt\/","title":{"rendered":"Victron - Multiplus II - Inverter defekt?"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>\n<p class=\"wp-block-paragraph\">Inverteren <em>Victron Multiplus II<\/em> f\u00e5s i forskellige str\u00f8m- og batteriversioner. F\u00e6lles for dem alle er, at de har en mekanisk t\u00e6nd\/sluk-knap, som ikke kun fungerer som en s\u00e5dan, men ogs\u00e5 som en valgknap for driftstilstanden.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>0 = <code>slukket<\/code><\/li>\n\n\n\n<li>1 = <code>Opladning og inverterdrift sl\u00e5et til<\/code><\/li>\n\n\n\n<li>2 = <code>Opladningstilstand sl\u00e5et til, invertertilstand sl\u00e5et fra<\/code><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Man skulle tro, at det var nemt: Man flytter bare kontakten til den \u00f8nskede position, og s\u00e5 er alt i orden. Men s\u00e5dan er det ikke!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Indstillinger i Victron Cerbo GX<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis du har en s\u00e5dan inverter, har du ogs\u00e5 installeret andre Victron-komponenter, som f.eks. <em>MPPT-controller<\/em>hvis det er n\u00f8dvendigt. <em>Lynx shunt<\/em>osv. og til sidst hele installationen ved hj\u00e6lp af <em>Cerbo GX ber\u00f8ringspaneler<\/em> overv\u00e5ge og kontrollere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den <em>Cerbo GX ber\u00f8ringspanel<\/em> giver adgang til alle tilsluttede systemer i menuen, inklusive <em>Victron Multiplus II<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Under <code>Menu<\/code> - <code>Indstillinger<\/code> - <code>Multiplus II <\/code>- <code>Afbrydere<\/code> kan f\u00f8lgende funktionsvarianter v\u00e6lges:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fra<\/li>\n\n\n\n<li>Kun opladning T\u00e6ndt<\/li>\n\n\n\n<li>Kun inverter t\u00e6ndt<\/li>\n\n\n\n<li>A<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Disse indstillinger <strong>overskrive<\/strong> kontaktens position p\u00e5 enheden!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis tilstanden \"Kun opladning\" er valgt, vil inverteren ikke starte driften under nogen omst\u00e6ndigheder.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den <em>Victron Multiplus II<\/em> er derfor ikke defekt, men er blot baseret p\u00e5, hvad indstillingerne p\u00e5 <em>Cerbo GX ber\u00f8ringspanel<\/em> specificere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det anbefales kun at v\u00e6lge invertertilstand, hvis det kan udelukkes, at str\u00f8mkr\u00e6vende forbrugere som f.eks. elvarme eller induktionskomfurer kan blive aktive for at forhindre for tidlig afladning af batteriet. For eksempel med en landstr\u00f8msforbindelse for at klare kortvarige(!) str\u00f8mafbrydelser uden afbrydelse eller - forudsat anst\u00e6ndigt solskin - for at tilberede rundstykker i varmluftovnen (maks. 1.600 W) i 18 minutter, for at starte den fuldautomatiske kaffemaskine (maks. intermitterende 1.400 W) i 5 minutter eller for at koge 8-minutters \u00e6g i \u00e6ggekogeren (300 W) til perfektion, eller for at riste br\u00f8det p\u00e5 3 minutter (930 W), indtil det er gyldent gult.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Med andre ord: Alt, hvad der kun kr\u00e6ver et par minutters h\u00f8jere effekt, kan sagtens lade sig g\u00f8re med inverterdrift p\u00e5 farten.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>Victron Multiplus II-inverteren f\u00e5s i forskellige str\u00f8m- og batteriversioner. F\u00e6lles for dem alle er, at de har en mekanisk t\u00e6nd\/sluk-kontakt, som ikke kun fungerer som en s\u00e5dan, men ogs\u00e5 som en omskifter for driftstilstanden. Man skulle m\u00e5ske tro, at det var nemt: Man flytter bare kontakten til den \u00f8nskede position, og s\u00e5 er alt...&nbsp;<a href=\"https:\/\/csiag.eu\/da\/blog\/2023\/03\/27\/victron-multiplus-ii-inverter-defekt\/\" rel=\"bookmark\">L\u00e6s mere \"<span class=\"screen-reader-text\">Victron - Multiplus II - Inverter defekt?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[317,344],"tags":[1294,521,1296,1295,1293,528,1289],"class_list":["post-3679","post","type-post","status-publish","format-standard","hentry","category-autarkie-im-wohnwagen-wohnmobil","category-victron-systemloesung","tag-betriebsmodus","tag-cerbo-gx","tag-einstellungen","tag-inverter","tag-laden","tag-mppt-regler","tag-multiplus-ii-2"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/3679","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/comments?post=3679"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/3679\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/media?parent=3679"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/categories?post=3679"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/tags?post=3679"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}