{"id":3823,"date":"2023-03-28T06:02:51","date_gmt":"2023-03-28T06:02:51","guid":{"rendered":"https:\/\/csiag.eu\/?p=3823"},"modified":"2023-03-28T06:05:13","modified_gmt":"2023-03-28T06:05:13","slug":"victron-multiplus-ii-inverter-overbelastning","status":"publish","type":"post","link":"https:\/\/csiag.eu\/da\/blog\/2023\/03\/28\/victron-multiplus-ii-inverter-overload\/","title":{"rendered":"Victron - Multiplus II - Overbelastning af inverter?"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> &lt; 1<\/span> <span class=\"rt-label rt-postfix\">Minut<\/span><\/span>\n<p class=\"wp-block-paragraph\">Victron Multiplus II k\u00f8rte perfekt hele tiden. Pludselig viser den \"Overload\" og slukker, kun for at t\u00e6nde igen umiddelbart efter - og efter et stykke tid for at spille det samme spil igen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Overbelastning? For meget belastning? Et kig p\u00e5 <em>Victron Cerbo GX ber\u00f8ringspanel<\/em> viser kun omkring 300 W AC-belastning. S\u00e5 hvorfor er der en overbelastning? Omkring 80 W kommer ind via solceller, s\u00e5 der er heller ingen reel overbelastning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis du ser n\u00e6rmere p\u00e5 omst\u00e6ndighederne, vil du opdage, at fejlen altid opst\u00e5r, n\u00e5r solen skinner for fuld kraft. S\u00e5 hvad har solen med overbelastning at g\u00f8re?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Og nu, <em>Victron Cerbo GX<\/em> og de forbundne enheder styrer hinanden intelligent. Nogle gange mere intelligent end brugeren ...<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For n\u00e5r batterierne er fulde, og solcellerne leverer str\u00f8m, ved Multiplus ikke, hvad den skal g\u00f8re med den overskydende str\u00f8m og f\u00f8ler sig derfor \"overbelastet\" med opgaven. Betyder det, at solcellemodulerne skal slukkes? Nej, for kontrolsystemet i <em>Victron Cerbo GX<\/em> meget bedre. Du skal dog fort\u00e6lle den i indstillingerne, at den ogs\u00e5 har en j\u00e6vnstr\u00f8mskilde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00e5 videre <em>Victron Cerbo GX ber\u00f8ringspanel<\/em> kald menuen frem, indtast <em>Indstillinger<\/em> og i <em>Systemops\u00e6tning<\/em> Aktiv\u00e9r indstillingen \"Har DC\".<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tilbage i sidevisningen er der nu kommet et ekstra \"DC Power\"-infofelt nederst i midten mellem batteriet og MPPT-controllersymbolet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nu kan selv <em>Victron Multiplus II<\/em>at der ud over dens opladningstjenester er andre ivrige hj\u00e6lpere involveret i batteriets opladningsproces. Og se: Den viser ikke l\u00e6ngere nogen \"overbelastning\" og kan nu helt afslappet hellige sig sine egne opgaver igen.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> &lt; 1<\/span> <span class=\"rt-label rt-postfix\">Minut<\/span><\/span>Die ganze Zeit lief der Victron Multiplus II einwandfrei. Pl\u00f6tzlich zeigt er &#8222;Overload&#8220; an und schaltet ab, um gleich darauf wieder einzuschalten &#8211; und, nach einer Weile, wieder das selbe Spiel zu treiben. Overload? Zu viel Last? Ein Blick auf das Victron Cerbo GX Touch Panel zeigt lediglich rund 300 W AC Last an. Weshalb&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/da\/blog\/2023\/03\/28\/victron-multiplus-ii-inverter-overload\/\" rel=\"bookmark\">L\u00e6s mere \"<span class=\"screen-reader-text\">Victron - Multiplus II - Overbelastning af inverter?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[317,344],"tags":[521,1301,1297,1298,528,1289,1299,1300,519],"class_list":["post-3823","post","type-post","status-publish","format-standard","hentry","category-autarkie-im-wohnwagen-wohnmobil","category-victron-systemloesung","tag-cerbo-gx","tag-dc-power","tag-dc-quelle","tag-has-dc","tag-mppt-regler","tag-multiplus-ii-2","tag-overload","tag-ueberlast","tag-victron"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/3823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/comments?post=3823"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/3823\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/media?parent=3823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/categories?post=3823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/tags?post=3823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}