{"id":4800,"date":"2023-07-21T12:17:35","date_gmt":"2023-07-21T12:17:35","guid":{"rendered":"https:\/\/csiag.eu\/?p=4800"},"modified":"2025-08-03T07:17:15","modified_gmt":"2025-08-03T07:17:15","slug":"forskelle-i-vandkvalitet","status":"publish","type":"post","link":"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/","title":{"rendered":"Forskelle i vandkvalitet"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Indholdsfortegnelse<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Regenwasser\" >Regnvand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Grundwasser\" >Grundvand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Trinkwasser\" >Drikkevand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Mineralwasser\" >Mineralvand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Meerwasser\" >Havvand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Destilliertes_Wasser\" >Destilleret vand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Osmose-Wasser\" >Osmosevand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Reinstwasser\" >Ultrarent vand<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Hochreines_Wasser\" >Vand med h\u00f8j renhed<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/#Leitfahigkeits-Messung_TDS\" >M\u00e5ling af ledningsevne (TDS)<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>\n<p class=\"wp-block-paragraph\">Opdateret 14.07.2024<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Forskellene i vandkvalitet er i f\u00f8rste omgang ikke s\u00e6rlig indlysende. Drikkevand, spildevand, regnvand, grundvand, havvand, mineralvand og destilleret vand er de mest almindeligt anerkendte klassifikationer. Derudover er der andre forskelle, som f.eks. mineralvand, osmosevand, rent vand og ultrarent vand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lad os starte med at n\u00e6vne \"levende vand\", som i \u00f8jeblikket boomer i reklamer. Nogle producenter reklamerer for deres systemer med p\u00e5stande som \"energiseret\", \"bioenergi\" eller \"energimodul\", som bruger \"programmeret naturlig, h\u00f8jenergisk kildevandsinformation\" til at genskabe vandets oprindelige friskhed og vitalitet. De undlader dog at freml\u00e6gge dokumentation for dette, som ville kunne holde til en rent videnskabelig unders\u00f8gelse, og henviser til \"virksomhedshemmeligheden\" (som helt sikkert kunne beskyttes i henhold til patentlovgivningen, hvis den opfyldte patentkravene ...).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I \u00f8vrigt er \"levende vand\" et bibelsk citat, for eksempel i Johannes 4:14 \"<strong>Men den, der drikker af det vand, jeg giver ham, skal aldrig t\u00f8rste, men det vand, jeg giver ham, skal i ham blive en kilde med vand, der springer ud til evigt liv.<\/strong>\" eller i Johannes 7, 38 \"<strong>Den, der tror p\u00e5 mig, som Skriften har sagt, ud af hans krop skal der flyde floder af levende vand.<\/strong>n.\"<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nu til forskellene mellem de forskellige typer vand, vi har til r\u00e5dighed ...<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Regenwasser\"><\/span>Regnvand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Regnvand er allerede forurenet, n\u00e5r det regner ned fra skyerne, idet det ud over st\u00f8vpartikler ogs\u00e5 indeholder termisk (nedbrydes f\u00f8rst ved temperaturer over 400 \u00b0C) og kemisk meget stabile per- og polyfluorerede alkylforbindelser (PFAS), hvoraf mange ikke kan nedbrydes, men ophobes i menneske- og dyrev\u00e6v. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I omr\u00e5der med PFAS-forurenet drikkevand er der registreret statistisk signifikante stigninger i sygdomsm\u00f8nstre som diabetes mellitus, cerebrovaskul\u00e6re sygdomme, Alzheimers, hjerteanfald og h\u00f8jere d\u00f8delighed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Da disse forbindelser kun kan nedbrydes ufuldst\u00e6ndigt i rensningsanl\u00e6g, bruges aktivt kul til de langk\u00e6dede PFAS'er.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det \u00f8nskede niveau af PFAS-forurening er 100 ng\/l, mens 300 ng\/l betragtes som \"tolerabelt for livet\". Drikkevand anses ikke l\u00e6ngere for at v\u00e6re brugbart over 5 \u03bcg\/l.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Regnvand har en ledningsevne p\u00e5 omkring 30 \u03bcS\/cm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Grundwasser\"><\/span>Grundvand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Grundvandet er forurenet med vandopl\u00f8selige og flydende komponenter fra ukontrolleret oplagret affald, spildevand fra l\u00e6kager i kloakr\u00f8r, vejafvanding (f.eks. d\u00e6kslid, afisningssalte), g\u00f8dning og pesticider, industrielt og kommercielt spildevand, mineralolier osv.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Is\u00e6r nitratforurening udg\u00f8r en stor sundhedsrisiko: Selv langvarig brug af vand med mere end 16,75 mg\/l for\u00e5rsager <a href=\"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ijc.31306\" target=\"_blank\" rel=\"noreferrer noopener\">Risiko<\/a> for at udvikle tarmkr\u00e6ft stiger markant.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Trinkwasser\"><\/span>Drikkevand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Drikkevandets kvalitet er kendetegnet ved tilstedev\u00e6relsen af urenheder i vandet. <em>Bekendtg\u00f8relse om drikkevand (TrinkwV)<\/em> <a href=\"https:\/\/www.dvgw.de\/medien\/dvgw\/wasser\/verordnung\/trinkwasserverordnung-2023.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Den f\u00f8derale lovtidende 159\/2023<\/a> defineret den 24. juni 2023.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For ingredienser og gr\u00e6nsev\u00e6rdier henvises til ovenn\u00e6vnte forordning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ledningsevnen (parameter for summen af alle indholdsstoffer) i drikkevand er fastsat til en gr\u00e6nsev\u00e6rdi p\u00e5 2,79 mS\/cm (milli-Siemens per centimeter) i Tyskland.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Mineralwasser\"><\/span>Mineralvand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Den <em>Bekendtg\u00f8relse om naturligt mineralvand, kildevand og bordvand<\/em> (<a href=\"https:\/\/gesetze-im-internet.de\/min_tafelwv\/BJNR010360984.html\" target=\"_blank\" rel=\"noreferrer noopener\">Bekendtg\u00f8relse om mineral- og bordvand<\/a>) regulerer terminologien, herunder indholdet (gr\u00e6nsev\u00e6rdien) af naturligt forekommende komponenter i naturligt mineralvand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Forordningen, der var g\u00e6ldende fra 1. januar 2006, blev \u00e6ndret den 1. januar 2008 for at inkludere gr\u00e6nsev\u00e6rdier for fluorid. V\u00e6rdien for nikkel blev reduceret fra 0,05 til 0,02 mg\/liter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00f8lgende tabel indeholder en sammenligning af lovm\u00e6ssigt definerede gr\u00e6nsev\u00e6rdier for ingredienser i drikkevand og mineralvand. V\u00e6rdier i parentes i tabellen repr\u00e6senterer gr\u00e6nsev\u00e6rdier, der g\u00e6lder fra 2028 eller 2030.<\/p>\n\n\n\n<table id=\"tablepress-14\" class=\"tablepress tablepress-id-14\" aria-describedby=\"tablepress-14-description\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Komponenter<\/th><th class=\"column-2\">Gr\u00e6nsev\u00e6rdi TrinkwV<\/th><th class=\"column-3\">Begr\u00e6ns min\/tabelWV<\/th><th class=\"column-4\">Borderline f. Sp\u00e6db\u00f8rn<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Antimon<\/td><td class=\"column-2\">0,005 mg\/liter<\/td><td class=\"column-3\">0,005 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Arsenik<\/td><td class=\"column-2\">0,010 (0,004) mg\/liter<\/td><td class=\"column-3\">0,010 mg\/liter<\/td><td class=\"column-4\">&lt;0,05 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Barium<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">1,0 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Bly<\/td><td class=\"column-2\">0,01 (0,005) mg\/Ltr.<\/td><td class=\"column-3\">0,010 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Borat<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">30,0 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Krom<\/td><td class=\"column-2\">0,025 (0,005) mg\/liter<\/td><td class=\"column-3\">0,050 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Fluor<\/td><td class=\"column-2\">1,5 mg\/liter<\/td><td class=\"column-3\">5,0 mg\/liter<\/td><td class=\"column-4\">&lt;0,7 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Cadmium<\/td><td class=\"column-2\">0,003 mg\/liter<\/td><td class=\"column-3\">0,003 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Kobber<\/td><td class=\"column-2\">2,0 mg\/liter<\/td><td class=\"column-3\">1,0 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Mangan<\/td><td class=\"column-2\">0,05 mg\/liter<\/td><td class=\"column-3\">0,5 mg\/liter<\/td><td class=\"column-4\">&lt;0,05 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Natrium<\/td><td class=\"column-2\">200,0 mg\/liter<\/td><td class=\"column-3\"><\/td><td class=\"column-4\">&lt; 20,0 mg\/liter (lavt natriumindhold)<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Nikkel<\/td><td class=\"column-2\">0,020 mg\/liter<\/td><td class=\"column-3\">0,020 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Nitrat<\/td><td class=\"column-2\">50 mg\/liter<\/td><td class=\"column-3\">50 mg\/liter<\/td><td class=\"column-4\">&lt;10,0 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Nitrit<\/td><td class=\"column-2\">0,5 mg\/liter<\/td><td class=\"column-3\">0,1 mg\/liter<\/td><td class=\"column-4\">&lt;0,02 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Kviks\u00f8lv<\/td><td class=\"column-2\">0,0010 mg\/liter<\/td><td class=\"column-3\">0,0010 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Selen<\/td><td class=\"column-2\">0,010 mg\/liter<\/td><td class=\"column-3\">0,010 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Sulfat<\/td><td class=\"column-2\">250 mg\/liter<\/td><td class=\"column-3\"><\/td><td class=\"column-4\">&lt;240,0 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Uran<\/td><td class=\"column-2\">0,01 mg\/liter<\/td><td class=\"column-3\"><\/td><td class=\"column-4\">&lt;0,02 mg\/liter.<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Cyanid<\/td><td class=\"column-2\">0,050 mg\/liter<\/td><td class=\"column-3\">0,070 mg\/liter<\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<span id=\"tablepress-14-description\" class=\"tablepress-table-description tablepress-table-description-id-14\"><\/span>\n<!-- #tablepress-14 from cache -->\n\n\n<p class=\"wp-block-paragraph\">Nogle producenter af s\u00e5kaldte \"levende kildevand\"-systemer (eller lignende) henviser til s\u00e6rligt d\u00e5rlige mineralvandskvaliteter, som ofte ikke engang opfylder kravene i drikkevandsforordningen. Analyserne er ikke opdaterede, og oplysningerne p\u00e5 etiketterne afspejler derfor muligvis ikke de faktiske data for indholdet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I hvilket omfang s\u00e5danne udsagn er holdbare i henhold til konkurrencelovgivningen, og is\u00e6r om de er korrekte, kan hurtigt afklares ved en kort korrespondance med den respektive producent. Under alle omst\u00e6ndigheder b\u00f8r man ikke lade sig narre og selv unders\u00f8ge, om der kan v\u00e6re tale om at p\u00e5virke k\u00f8berne i en u\u00f8nsket retning.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Meerwasser\"><\/span>Havvand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Havvand er kendetegnet ved et relativt h\u00f8jt saltindhold, i gennemsnit 3,5 %. Med 0,2-2 % har \u00d8sters\u00f8en stort set intet salt sammenlignet med Det D\u00f8de Hav med 28 %. Det har en gennemsnitlig ledningsevne p\u00e5 56 mS\/cm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Afsaltningsanl\u00e6g til havvand reducerer saltindholdet til et minimum, der kan drikkes, ved at tils\u00e6tte calciumhydrogencarbonat. Da afsaltning er en meget energikr\u00e6vende proces, bruges der ofte spildvarme fra atomkraftv\u00e6rker (ogs\u00e5 p\u00e5 skibe, hangarskibe eller atomub\u00e5de), men ogs\u00e5 fra kul-, gas- eller oliedrevne anl\u00e6g.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Destilliertes_Wasser\"><\/span>Destilleret vand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Destilleret vand fremstilles ved fordampning og efterf\u00f8lgende kondensering under anvendelse af en meget h\u00f8j energim\u00e6ngde. Dette fjerner i h\u00f8j grad salte, organiske stoffer og mikroorganismer. Ledningsevnen er kun 0,5 - 5,5 \u00b5S\/cm (mikrosiemens pr. centimeter).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Flerdobbelt destilleret vand tilbydes i dobbelte eller tredobbelte destillater og opbevares i kvarts- eller platinbeholdere, fordi spor af silica ville opl\u00f8ses fra glasbeholdere under kogning og dermed forurene destillatet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Osmose-Wasser\"><\/span>Osmosevand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vand fra det omvendte osmosesystem filtreres flere gange ned til 0,02 \u00b5m og opn\u00e5r en ledningsevne p\u00e5 1 - 50 \u00b5S\/cm. <br>Det antages generelt, at et omvendt osmosesystem opn\u00e5r omkring 10 % af den konduktansv\u00e6rdi, der er tilg\u00e6ngelig p\u00e5 indgangssiden.<br>Selvom omvendt osmose ikke opn\u00e5r samme renhedsgrad som destilleret vand, er det mere hygiejnisk til drikkevandsproduktion.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reinstwasser\"><\/span>Ultrarent vand<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ultrarent vand produceres ved hj\u00e6lp af et st\u00e6rkt alkalisk mixed-bed-system og bruges industrielt, f.eks. i halvlederindustrien. Ledningsevnen er 0,1 - 1 \u00b5S\/cm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hochreines_Wasser\"><\/span>Vand med h\u00f8j renhed<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">H\u00f8jrent vand er n\u00f8dvendigt inden for f.eks. medicin, den farmaceutiske industri og molekyl\u00e6rbiologi og produceres i ionbyttersystemer med blandede senge. Ledningsevnen er kun 0,052 - 0,1 \u00b5S\/cm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leitfahigkeits-Messung_TDS\"><\/span>M\u00e5ling af ledningsevne (TDS)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En ledningsevnem\u00e5ler er n\u00f8dvendig for at bestemme ledningsevnen i forskellige typer vand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ud over den rene funktion af ledningsevnem\u00e5ling tilbyder s\u00e5danne enheder ogs\u00e5 bestemmelse af TDS-v\u00e6rdien (<em>Opl\u00f8ste faste stoffer i alt<\/em>) i ppm (<em>dele pr. million<\/em>). Denne v\u00e6rdi giver oplysninger om opl\u00f8ste faste stoffer i form af ioner, f.eks. metaller, salte og mineraler.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De \"m\u00e5leapparater\", der ofte findes i \"milj\u00f8et\" i st\u00f8rrelsesordenen 20-50 euro, b\u00f8r i bedste fald betragtes som \"g\u00e6ttev\u00e6rkt\u00f8jer\". De giver kun et groft sk\u00f8n og indikerer en tendens.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Enhver, der seri\u00f8st \u00f8nsker en reproducerbar og p\u00e5lidelig m\u00e5lev\u00e6rdi, kan ikke undg\u00e5 at k\u00f8be et apparat, der ogs\u00e5 f\u00e5s i en \"kalibreret\" version s\u00e5vel som en ukalibreret version.<br>Et kalibreringscertifikat angiver i sidste ende \"kun\", at enheden leverer en v\u00e6rdi, der er n\u00f8jagtig identisk med en referenceenhed i et centralt omr\u00e5de ved en standardiseret temperatur.<br>En ukalibreret enhed har ikke denne reference. Den kan derfor vise en v\u00e6rdi lidt over eller under denne referencev\u00e6rdi.<br>Temperaturkompensation er vigtig, da m\u00e5lingen altid skal justeres elektronisk i forhold til 25 \u00b0C for at svare til den faktiske v\u00e6rdi og v\u00e6re i overensstemmelse med standardiseringen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det betyder, at to minimumskriterier skal v\u00e6re opfyldt: funktionen til m\u00e5ling af ledningsevne og temperatur. Hvis du stadig \u00f8nsker at kende TDS-v\u00e6rdien, skal du bruge den ekstra TDS-m\u00e5lefunktion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I det nuv\u00e6rende mest gunstige tilf\u00e6lde ligger vi p\u00e5 ca. <a href=\"https:\/\/www.pce-instruments.com\/deutsch\/messtechnik\/messgeraete-fuer-alle-parameter\/leitfaehigkeitsmessgeraet-pce-instruments-leitfaehigkeitstester-pce-ph-25-det_5884810.htm?_list=kat&amp;_listpos=7\" target=\"_blank\" rel=\"noreferrer noopener\">390,- Euro<\/a>eller ca. <a href=\"https:\/\/www.pce-instruments.com\/deutsch\/messtechnik\/messgeraete-fuer-alle-parameter\/leitfaehigkeitsmessgeraet-lutron-electronic-enterprise-co.-ltd.-leitfaehigkeitsmessgeraet-pce-phd-1-det_17447.htm?_list=kat&amp;_listpos=9\" target=\"_blank\" rel=\"noreferrer noopener\">530,- Euro<\/a> inkl. TDS-funktion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Udf\u00f8relse af en gyldig m\u00e5ling kr\u00e6ver en n\u00f8jagtig procedure i overensstemmelse med de respektive brugsanvisninger, is\u00e6r med hensyn til reng\u00f8ring af sensoren med destilleret vand (DAB), der har en elektrisk ledningsevne p\u00e5 &lt; 1,1 \u00b5S\/cm.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e6setid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>Opdateret 14.07.2024 Forskellene i vandkvalitet er i f\u00f8rste omgang ikke s\u00e6rlig indlysende. Drikkevand, spildevand, regnvand, grundvand, havvand, mineralvand og destilleret vand er de mest almindeligt anerkendte klassifikationer. Ud over disse er der andre forskelle, s\u00e5som mineralvand, osmosevand, rent vand og ultrarent vand. Udtrykket \"levende vand\", som i \u00f8jeblikket boomer i reklamer, b\u00f8r n\u00e6vnes i begyndelsen. Nogle producenter reklamerer for deres systemer...&nbsp;<a href=\"https:\/\/csiag.eu\/da\/blog\/2023\/07\/21\/unterschiede-der-wasserqualitaeten\/\" rel=\"bookmark\">L\u00e6s mere \"<span class=\"screen-reader-text\">Forskelle i vandkvalitet<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[339,338],"tags":[2037,2038,2036,2032,2035,2021,1581,2018,2016,2030,1214,2023,2027,1413,2022,2024,2017,2019,1384,2029,2028,2026,2031,1668,2020,2034,2025,2013,2015,2014,587,584,2033,2011,2012],"class_list":["post-4800","post","type-post","status-publish","format-standard","hentry","category-umkehr-osmose","category-wasser-management","tag-aktivkohle","tag-alkylverbindung","tag-alzheimer","tag-belastung","tag-darmkrebs","tag-desilliertes-wasser","tag-diabetes","tag-entsalzung","tag-grundwasser","tag-halbleiterindustrie","tag-herzinfarkt","tag-hochreines-wasser","tag-ionentauscher","tag-leitfaehigkeit","tag-leitfaehigkeitsmessung","tag-medizin","tag-meerwasser","tag-meerwasserentsalzung","tag-messgeraet","tag-mischbett-system","tag-mischbettanlage","tag-molekularbiologie","tag-nitrat","tag-osmose-anlage","tag-osmose-wasser","tag-pfas","tag-pharmaindustrie","tag-regenwasser","tag-reinstwasser","tag-reinwasser","tag-trinkwasser","tag-umkehr-osmose","tag-verunreinigung","tag-wasser","tag-wasserqualitaet"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/4800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/comments?post=4800"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/posts\/4800\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/media?parent=4800"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/categories?post=4800"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/da\/wp-json\/wp\/v2\/tags?post=4800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}