{"id":6792,"date":"2024-03-01T16:15:43","date_gmt":"2024-03-01T16:15:43","guid":{"rendered":"https:\/\/csiag.eu\/?p=6792"},"modified":"2024-12-29T14:43:16","modified_gmt":"2024-12-29T14:43:16","slug":"teltonika-rutx50-failover-load-balancing","status":"publish","type":"post","link":"https:\/\/csiag.eu\/en\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/","title":{"rendered":"Teltonika RUTX50 \u2013 Failover \/ Load Balancing"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/en\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Failover_Konfiguration\" >Failover configuration<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/en\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Interface_configuration\" >Interface configuration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/en\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Rule\" >Rule<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/en\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Loadbalancing_Konfiguration\" >Load balancing configuration<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading time<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>\n<p class=\"wp-block-paragraph\">Some Teltonika routers, including the RUTX50, provide the functionalities <em>Failover<\/em> and <em>Load balancing<\/em> available.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Failover<\/em> offers the possibility to switch to another connection type if one fails, e.g. from a WLAN access point to mobile data, or from WAN (e.g. Starlink) to mobile data, even automatic switching between all conditions is possible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Load balancing<\/em> serves to increase the bandwidth, for example by using WAN and WLAN or LTE in parallel, using both bandwidths together. However, this does not refer to ONE connection, ONE client.<br>For example, if a download is initiated by client A, load balancing will not complete it any faster. But if another client B starts a Zoom meeting, for example, this is handled via the other channel and does not slow down the ongoing download from client A.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Failover<\/em> and <em>Load balancing<\/em> can only be used exclusively and cannot be used simultaneously, even if the configuration page suggests otherwise.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Failover_Konfiguration\"><\/span>Failover configuration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To activate the <em>Failover<\/em>function, all you have to do is activate the corresponding interfaces by setting the respective switches to \u201con\u201d.<br>The example here is the most common variant: WAN first and LTE second. By default, traffic is routed via WAN. If WAN fails, LTE is automatically activated; if WAN returns, LTE is deactivated and WAN is activated.<\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"349\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-1024x349.png\" alt=\"\" class=\"wp-image-7004\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-1024x349.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-1536x524.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-2048x698.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-18x6.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-300x102.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-768x262.png 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Network \u2013 Failover<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Under <em>Fashion<\/em> the function is set <em>Failover<\/em> OR <em>Load balancing<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The specific specifications for when failover should become active are set by clicking on <em>Edit<\/em> defined.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"619\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-1024x619.png\" alt=\"\" class=\"wp-image-8496\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-1024x619.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-18x12.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-300x181.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-768x464.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11.png 1174w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Interface_configuration\"><\/span>Interface configuration<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Under <em>Interface configuration<\/em> for example, it is specified here that all <em>3<\/em> seconds (<kbd>Interval<\/kbd>) a test is to be performed for which the following rule (<em>Rule<\/em>) defines that a ping to the IP address (<kbd>Track IP<\/kbd>) <em>8.8.8.8 <\/em>is executed. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rule\"><\/span>Rule<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The value <em>1<\/em> (<kbd>Reliability<\/kbd>) assumes that exactly one host is assigned to exactly one (<kbd>Count<\/kbd>) Ping does not give an answer. Is this <em>3<\/em>-subject (<kbd>Up \/ Down<\/kbd>) is the case, then it is assumed that the connection is disconnected and thus the initially defined <em>Interface configuration<\/em> <kbd>Flush connection on<\/kbd> \u201e<em>Disconnected<\/em>\" and switches to the mobile data connection. However, if the ping is successful 3 times (<kbd>Up<\/kbd>), remain <em>WAN<\/em> <em>on-line<\/em> and <em>mob1s1a1<\/em> <em>standby<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By clicking on the button <em>Save &amp; Apply<\/em> (<em>Save &amp; Apply<\/em>) the changes will be saved and take effect.<\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Loadbalancing_Konfiguration\"><\/span>Load balancing configuration<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Particular attention is paid to the \u201cRatio\u201d parameter. It determines the traffic share that the respective interface takes over.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With a ratio of 1 and 1 (= 2), half of the traffic is distributed to interface 1 (WAN) and 2 (LTE). A ratio of 9 (WAN) and 1 (LTE) (= 10) results in a split of 90 % (nine tenths) WAN and 10 % (one tenth) LTE usage.<\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"243\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-1024x243.png\" alt=\"\" class=\"wp-image-7003\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-1024x243.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-1536x364.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-2048x485.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-18x4.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-300x71.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-768x182.png 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Network \u2013 load balancing<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Here, under <em>Fashion<\/em> the function <em>Load balancing<\/em> chosen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By clicking on the button <em>Save &amp; Apply<\/em> (<em>Save &amp; Apply<\/em>) the changes will be saved and take effect.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading time<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>Some Teltonika routers, including the RUTX50, provide the failover and load balancing functionalities. Failover offers the possibility to switch to another connection type in case of failure, e.g. from a WLAN access point to mobile data, or from WAN (e.g. Starlink) to mobile data, even automatic switching between all conditions is possible. Load balancing...&nbsp;<a href=\"https:\/\/csiag.eu\/en\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/\" rel=\"bookmark\">Read More \"<span class=\"screen-reader-text\">Teltonika RUTX50 \u2013 Failover \/ Load Balancing<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"no","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[3192,3191,2553,2868],"tags":[2604,2042,3833,3838,3835,2873,3837,3836,3830,573,3193,725,3839,3196,2793,3195,3832,574,2683,2682,3831,3194,3834,3170,3178,563],"class_list":["post-6792","post","type-post","status-publish","format-standard","hentry","category-failover","category-loadbalancing","category-netzwerk-technik","category-router","tag-ausfall","tag-client","tag-count","tag-disconnected","tag-down","tag-failover","tag-flush-connection-on","tag-interface-configuration","tag-interval","tag-konfiguration","tag-loadbalancing","tag-lte","tag-mob1s1a1","tag-mode","tag-ping","tag-ratio","tag-reliability","tag-router","tag-rutx50","tag-teltonika","tag-track-ip","tag-traffic","tag-up","tag-wan","tag-wifi","tag-wlan"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/posts\/6792","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/comments?post=6792"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/posts\/6792\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/media?parent=6792"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/categories?post=6792"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/en\/wp-json\/wp\/v2\/tags?post=6792"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}