{"id":3661,"date":"2023-03-25T19:05:55","date_gmt":"2023-03-25T19:05:55","guid":{"rendered":"https:\/\/csiag.eu\/?p=3661"},"modified":"2023-04-18T13:47:54","modified_gmt":"2023-04-18T13:47:54","slug":"control-remoto-del-generador-hibrido","status":"publish","type":"post","link":"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/","title":{"rendered":"Generador h\u00edbrido \u2013 control remoto"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Tabla de contenido<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Materialien\" >Materiales<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Verkabelung\" >cableado<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Relais_und_Generator-Zundung_-Anlasser-Funktion\" >Funci\u00f3n de encendido\/arranque de rel\u00e9 y generador<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Schlusselschalter_Modifikation\" >Modificaci\u00f3n del interruptor de llave<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#4-fach-Schaltaktor_und_PWM-Vor-Ruck-Regler\" >Actuador de conmutaci\u00f3n cu\u00e1druple y controlador de avance\/retroceso PWM<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Schubstangenmotor\" >motor de varilla de empuje<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Modifikation_am_PWM-Vor-Ruck-Regler\" >Modificaci\u00f3n del controlador de avance\/retroceso PWM<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Trockenubung\" >Ejecuci\u00f3n en seco<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Variablen_anlegen\" >Crear variables<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Gerate_Kanale_benennen\" >Nombrar dispositivos\/canales<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Programme_anlegen\" >Crear programas<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Programm_SV_Gen_Start\" >Programa SV_Gen_Start<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Programm_SV_Gen_Aus\" >Programa SV_Gen_Aus<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Visualisierung\" >Visualizaci\u00f3n<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/#Funktionstest\" >prueba funcional<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tiempo de leer<\/span> <span class=\"rt-time\"> 5<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p class=\"wp-block-paragraph\">El fabricante suele ofrecer el control remoto de un generador h\u00edbrido con funci\u00f3n de arranque el\u00e9ctrico, pero los precios de esta opci\u00f3n suelen ser los correspondientes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En las autocaravanas, el generador suele instalarse en el garaje trasero. Si no te gusta babear con gasolina, dejar\u00e1s el tanque de gasolina vac\u00edo y har\u00e1s funcionar el generador con gasolina.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En cambio, en modo gas, el estrangulador se debe accionar al arrancar y, una vez arrancado el generador, se debe volver a cambiar seg\u00fan las instrucciones de uso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dado que el generador est\u00e1 encapsulado para reducir el ruido, el acceso es dif\u00edcil. Adem\u00e1s, el generador genera mucho calor de proceso, que tambi\u00e9n puede disiparse mediante dispositivos de ventilaci\u00f3n de tama\u00f1o adecuado, incluido un ventilador transversal montado en la salida de aire superior en la pared lateral de la autocaravana.<br>La llave de encendido para arrancar el generador a\u00fan se puede reemplazar usando un bot\u00f3n ubicado en el interior, pero solo se puede acceder a la palanca del estrangulador directamente en el generador, por supuesto solo despu\u00e9s de retirar la carcasa circundante, etc. Por lo tanto, aqu\u00ed se requieren habilidades creativas, si Quiero simplemente \u2013 encender el generador.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si de todos modos usa Homematic \/ RaspberryMatic en su casa rodante, puede usarlo para controlar el generador y usar el bot\u00f3n interno (radio) o el tel\u00e9fono celular \/ tableta para iniciar el generador, hacer que el estrangulador funcione autom\u00e1ticamente y luego apagar el generador nuevamente.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Materialien\"><\/span>Materiales<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">son necesarios <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1x12V <a href=\"https:\/\/www.amazon.de\/dp\/B07MM3N3VW?psc=1&amp;ref=ppx_yo2ov_dt_b_product_details\" target=\"_blank\" rel=\"noreferrer noopener\">motor de varilla de empuje<\/a> <\/li>\n\n\n\n<li>1 x 12VPWM <a href=\"https:\/\/www.amazon.de\/dp\/B07FTG4M21?psc=1&amp;ref=ppx_yo2ov_dt_b_product_details\" target=\"_blank\" rel=\"noreferrer noopener\">Control de avance\/retroceso<\/a><\/li>\n\n\n\n<li>1x <a href=\"https:\/\/de.elv.com\/homematic-funk-schaltaktor-4-fach-hm-lc-sw4-wm-fuer-smart-home-hausautomation-099082\" target=\"_blank\" rel=\"noreferrer noopener\">Actuador de conmutaci\u00f3n Homematic de 4 v\u00edas HM-LC-Sw4-WM<\/a> (Arranque encendido, encendido apagado, estrangulador encendido\/apagado)<\/li>\n\n\n\n<li>2x <em><a href=\"https:\/\/www.amazon.de\/gp\/product\/B004Z0W1LM\/ref=ppx_od_dt_b_asin_title_s00?ie=UTF8&amp;psc=1\" target=\"_blank\" rel=\"noreferrer noopener\">Rel\u00e9s automotrices<\/a><\/em> (Arranque ON, Rel. I \/ Encendido OFF Rel. II)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verkabelung\"><\/span>cableado<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Relais_und_Generator-Zundung_-Anlasser-Funktion\"><\/span>Funci\u00f3n de encendido\/arranque de rel\u00e9 y generador<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El cableado es moderado. Los contactos de cierre de los dos rel\u00e9s, uno para &quot;encendido apagado&quot; y otro para &quot;arranque encendido&quot;, se conmutan en paralelo al interruptor de llave del generador.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las bobinas del rel\u00e9 est\u00e1n conectadas a tierra del veh\u00edculo con una tierra com\u00fan. La l\u00ednea positiva del rel\u00e9 I \u201cArranque ON\u201d est\u00e1 conectada al terminal de tornillo izquierdo (7) del canal 3. La l\u00ednea positiva al rel\u00e9 II \u201cEncendido apagado\u201d est\u00e1 conectada al terminal de tornillo izquierdo (9) del canal 4 del actuador de conmutaci\u00f3n de 4 v\u00edas. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Schlusselschalter_Modifikation\"><\/span>Modificaci\u00f3n del interruptor de llave<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El interruptor de llave del generador K&amp;S KS 3000 G tiene cuatro cables de conexi\u00f3n (contando en la parte posterior del interruptor de izquierda a derecha):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 \u2013 amarillo verdoso (Rel. II, Kl. 30)<\/li>\n\n\n\n<li>2 \u2013 negro (Rel. II, Kl. 87)<\/li>\n\n\n\n<li>3 \u2013 blanco (Rel. I, Kl. 30)<\/li>\n\n\n\n<li>4 \u2013 blanco y negro (Rel. I, Kl. 87)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">1 y 2 cortocircuitan el encendido (rel\u00e9 II, terminal 30 \/ 87), de modo que el generador se apaga, 3 y 4 (rel\u00e9 I, terminal 30 \/ 87) conmutan m\u00e1s al motor de arranque para arrancar el generador. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4-fach-Schaltaktor_und_PWM-Vor-Ruck-Regler\"><\/span>Actuador de conmutaci\u00f3n cu\u00e1druple y controlador de avance\/retroceso PWM<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los dos terminales de tornillo derechos (8 y 10) de los canales 3 y 4 est\u00e1n conectados al terminal de tornillo &quot;Power +&quot; (4) del controlador de avance\/retroceso PWM (extremo derecho). A esta conexi\u00f3n tambi\u00e9n se conduce la alimentaci\u00f3n de tensi\u00f3n positiva para el actuador de conmutaci\u00f3n de 4 v\u00edas desde el borne de tornillo (1) (\u201c+\u201d \u2013 exterior izquierdo). La l\u00ednea negativa del terminal de tornillo (2) (\u201c-\u201d \u2013 justo al lado) del actuador de conmutaci\u00f3n de 4 v\u00edas va al terminal de tornillo (3) \u201cPower -\u201d del controlador de avance\/retroceso PWM, as\u00ed como al suelo del veh\u00edculo. La alimentaci\u00f3n de tensi\u00f3n positiva al controlador y al actuador de conmutaci\u00f3n de 4 v\u00edas, que tambi\u00e9n est\u00e1 alimentado, se realiza a trav\u00e9s de un fusible de 2 A en el cable positivo a trav\u00e9s de una conexi\u00f3n a la tensi\u00f3n general de la autocaravana.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-5.png\" alt=\"\" class=\"wp-image-3674\" width=\"388\" height=\"119\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-5.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-5-300x92.png 300w\" sizes=\"(max-width: 388px) 100vw, 388px\" \/><figcaption class=\"wp-element-caption\">Fig. \u2013 Terminales\/botones del actuador de conmutaci\u00f3n de 4 v\u00edas<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-4.png\" alt=\"\" class=\"wp-image-3673\" width=\"225\" height=\"167\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-4.png 467w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-4-300x223.png 300w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><figcaption class=\"wp-element-caption\">Fig. \u2013 Terminal del controlador PWM<\/figcaption><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Schubstangenmotor\"><\/span>motor de varilla de empuje<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El motor de la varilla de empuje est\u00e1 conectado a los dos terminales de tornillo (1) menos y (2) m\u00e1s del controlador de avance\/retroceso PWM.<br>La posici\u00f3n est\u00e1ndar del motor de la varilla de empuje es <em>extendido<\/em> (para posici\u00f3n de estrangulamiento <em>Fase de puesta en marcha de GLP<\/em>).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"409\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/Gen_SSM_Choke.jpg\" alt=\"\" class=\"wp-image-4084\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/Gen_SSM_Choke.jpg 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/Gen_SSM_Choke-300x153.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/Gen_SSM_Choke-768x393.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">El motor del empujador se fija mediante un tornillo M6 a un perfil en U de aluminio adecuadamente curvado. La varilla de empuje tambi\u00e9n est\u00e1 equipada con un tornillo M6 y un perfil de aluminio prensado en el que se atornillan dos tornillos M3, asegurados con contratuercas, para mover program\u00e1ticamente la palanca del estrangulador hacia adelante y hacia atr\u00e1s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Modifikation_am_PWM-Vor-Ruck-Regler\"><\/span>Modificaci\u00f3n del controlador de avance\/retroceso PWM<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dado que el motor de varilla de empuje utilizado aqu\u00ed requiere alrededor de 10 segundos para su distancia m\u00e1xima de 5 cm, se puede quitar el potenci\u00f3metro conectado al controlador PWM (desenchufe el cable plano en la placa del potenci\u00f3metro), las conexiones 1 y 2 (blanca y roja, interrumpidas). ). ).<br>Alternativamente (\u00a1p\u00e9rdida de la garant\u00eda!) se pueden puentear los pines correspondientes (1 y 2, as\u00ed como 3 y 4) directamente en la placa con una gota de soldadura y sacar el cable del z\u00f3calo de la placa.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-777x1024.jpg\" alt=\"\" class=\"wp-image-3881\" width=\"365\" height=\"481\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-777x1024.jpg 777w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-1166x1536.jpg 1166w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-1554x2048.jpg 1554w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-228x300.jpg 228w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-768x1012.jpg 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Platine_Bruecken-scaled.jpg 1943w\" sizes=\"(max-width: 365px) 100vw, 365px\" \/><figcaption class=\"wp-element-caption\">Fig. \u2013 Pasadores puenteados 1\/2 y 3\/4 abajo a la izquierda<\/figcaption><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Trockenubung\"><\/span>Ejecuci\u00f3n en seco<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Encienda el controlador PWM de avance\/retroceso en el potenci\u00f3metro. Luego pruebe el funcionamiento de los cuatro canales de rel\u00e9 en el actuador de conmutaci\u00f3n de 4 v\u00edas. Presionando el bot\u00f3n<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 \u2013 Extender el motor de la varilla de empuje.<\/li>\n\n\n\n<li>2 \u2013 Retraer el motor de varilla de empuje<\/li>\n\n\n\n<li>3 \u2013 El rel\u00e9 de arranque se energiza<\/li>\n\n\n\n<li>4 \u2013 Rel\u00e9 de encendido energizado <\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si las cuatro funciones se han completado con \u00e9xito, se puede programar el control Homematic \/ Raspberrymatic.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Variablen_anlegen\"><\/span>Crear variables<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para la visualizaci\u00f3n usando AIO Creator y el control remoto a trav\u00e9s de tel\u00e9fono celular\/tableta, se deben crear las siguientes variables (ortograf\u00eda\/distingue entre may\u00fasculas y min\u00fasculas):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gen_AUS de tipo <em>Valor l\u00f3gico<\/em> (por defecto: <code>verdadero<\/code>)<\/li>\n\n\n\n<li>Escriba Gen_Choke <em>Lista de valores<\/em> (<code>LPG_START;LPG_OPERATION;LPG_OFF<\/code>)<\/li>\n\n\n\n<li>Gen_Start de tipo <em>Lista de valores<\/em> (<code>ARRANQUE;OPERACI\u00d3N;APAGADO<\/code>)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Gerate_Kanale_benennen\"><\/span>Nombrar dispositivos\/canales<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los canales del actuador de conmutaci\u00f3n cu\u00e1druple reciben los siguientes nombres en los siguientes programas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Canal 1 \u2013 <em>HG_SW_III_K1_Choke_Operation<\/em><\/li>\n\n\n\n<li>Canal 2 \u2013 <em>HG_SW_III_K2_Choke_Start<\/em><\/li>\n\n\n\n<li>Canal 3 \u2013 <em>HG_SW_III_K3_Gen_Starter<\/em><\/li>\n\n\n\n<li>Canal 4 \u2013 <em>HG_SW_III_K4_Gen_ON_AUS<\/em><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Programme_anlegen\"><\/span>Crear programas<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00f3lo necesitas crear dos programas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>SV_Gen_Aus<\/em> \u2013 se activa cuando cambia el estado de la variable <em>Generaci\u00f3n_fuera<\/em> en <code>verdadero<\/code> comenz\u00f3<\/li>\n\n\n\n<li><em>SV_Gen_Inicio<\/em> \u2013 se activa cuando cambia el estado de la variable <em>Generaci\u00f3n_fuera<\/em> en <code>incorrecto<\/code> comenz\u00f3<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Programm_SV_Gen_Start\"><\/span>Programa SV_Gen_Start<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"573\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-11-1024x573.png\" alt=\"\" class=\"wp-image-4090\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-11-1024x573.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-11-1536x860.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-11-300x168.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-11-768x430.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-11.png 1936w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">la variable <em>Gen_OFF<\/em> es predeterminado <code>verdadero<\/code>. Esto se hace, por ejemplo, presionando el bot\u00f3n <code>I<\/code> (Encendido) se presiona en la visualizaci\u00f3n de AIO Creator en el celular\/tableta, se activa el comando para cambiar al valor l\u00f3gico <code>incorrecto<\/code> enviado a la sede de Homematic\/RaspberryMatic.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este cambio inicia el programa. <em>SV_Gen_Inicio<\/em>para arrancar el generador.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">canal <em>4<\/em> del actuador de conmutaci\u00f3n de 4 v\u00edas conecta inmediatamente el encendido del generador. Al mismo tiempo, el canal 3 permitir\u00e1 que el rel\u00e9 de arranque se energice durante 5 segundos para encender el generador y arrancarlo (el segundo valor se puede ajustar seg\u00fan sea necesario).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un segundo despu\u00e9s la variable <em>Inicio_generaci\u00f3n<\/em> en <code>COMENZAR<\/code> configurado para proporcionar la visualizaci\u00f3n con una etiqueta amarilla (para &quot;Arranques del generador&quot;). <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Despu\u00e9s de 10 segundos, el canal 2 del actuador de conmutaci\u00f3n de 4 v\u00edas se activa durante 5 segundos (el tiempo de funcionamiento para la posici\u00f3n central del actuador de varilla de empuje (correspondiente a la posici\u00f3n del estrangulador \u201cFuncionamiento con GLP\u201d)).<br>La siguiente orden de conexi\u00f3n inicia el ciclo de tiempo especificado de 10 segundos de tiempo de conexi\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sin embargo, inmediatamente la variable se utiliza con fines de visualizaci\u00f3n. <em>Gen_Choke<\/em> en <code>LPG_Inicio<\/code> configurado para volver al estado despu\u00e9s de 10 segundos <code>operaci\u00f3n de GLP<\/code> para cambiar. Asimismo, el estado de la variable <em>Inicio_generaci\u00f3n<\/em> 10 segundos despu\u00e9s <code>Operaci\u00f3n<\/code> cambi\u00f3.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Programm_SV_Gen_Aus\"><\/span>Programa SV_Gen_Aus<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"494\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-12-1024x494.png\" alt=\"\" class=\"wp-image-4091\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-12-1024x494.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-12-1536x741.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-12-300x145.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-12-768x371.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-12.png 1936w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Pulsando el bot\u00f3n visualizado <code>0<\/code> (Apagar) se convierte en el comando para cambiar la variable. <em>Gen_OFF<\/em> al valor l\u00f3gico <code>incorrecto<\/code> interrumpido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El encendido del generador se interrumpe inmediatamente desconectando el canal 4 del actuador de conmutaci\u00f3n de 4 v\u00edas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando se enciende el canal 1, el motor de la varilla de empuje vuelve a su posici\u00f3n inicial para funcionamiento con GLP durante 5 segundos (el valor se puede ajustar si es necesario).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5 segundos despu\u00e9s la variable <em>Gen_Choke<\/em> en <code>GLP_START<\/code>, \u2013 inmediatamente \u2013 sin embargo, la variable <em>Inicio_generaci\u00f3n<\/em> en <code>FUERA DE<\/code> configurado para actualizar la visualizaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Visualisierung\"><\/span>Visualizaci\u00f3n<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Usando AIO Creator, la visualizaci\u00f3n del funcionamiento del generador se integr\u00f3 en la otra interfaz de visualizaci\u00f3n:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-3.png\" alt=\"\" class=\"wp-image-3670\" width=\"170\" height=\"107\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-3.png 382w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/image-3-300x188.png 300w\" sizes=\"(max-width: 170px) 100vw, 170px\" \/><figcaption class=\"wp-element-caption\">Fig. \u2013 Estado del generador.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Entre los dos teclados se encuentran dos LED dispuestos verticalmente uno encima del otro. El superior muestra el estado de la configuraci\u00f3n del estrangulador (amarillo = listo para <code>arranque de GLP<\/code>), el inferior muestra el estado del generador (gris = <code>Fuera de<\/code>).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Funktionstest\"><\/span>prueba funcional<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Finalmente, antes de la instalaci\u00f3n, una prueba funcional:<\/p>\n\n\n\n&lt;iframe height=&quot;426&quot; width=&quot;240&quot; style=&quot;border:none;overflow:hidden;display:block;margin:0 auto;&quot;\n src=&quot;https:\/\/csiag.eu\/wp-content\/uploads\/2023\/03\/Generator_Choke_Steuerung-SD-480p-SD-480p.mp4&quot; title=&quot;Generador - Choke\/Control&quot; frameborder=&quot;0&quot;\n<\/iframe>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tiempo de leer<\/span> <span class=\"rt-time\"> 5<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>El fabricante suele ofrecer el control remoto de un generador h\u00edbrido con funci\u00f3n e-start, pero los precios de esta opci\u00f3n suelen ser correspondientemente altos. En las autocaravanas, el generador suele instalarse en el garaje trasero. Si no te gusta andar con gasolina, puedes dejar el dep\u00f3sito vac\u00edo y hacer funcionar el generador con gas. Sin embargo, cuando funciona con gas, el estrangulador...&nbsp;<a href=\"https:\/\/csiag.eu\/es\/blog\/2023\/03\/25\/hybrid-generator-fernsteuerung\/\" rel=\"bookmark\">Vaciar m\u00e1s \"<span class=\"screen-reader-text\">Generador h\u00edbrido \u2013 control remoto<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"[\"title\",\"meta\",\"thumbnail\",\"content\",\"tags\",\"comments\"]","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1274,1273,346,347,353,348,1260],"tags":[1282,793,1287,1279,1275,1074,1277,1278,377,1075,1276,1283,1285,471,902,1284,1280,1281,1286,370,541,1288],"class_list":["post-3661","post","type-post","status-publish","format-standard","hentry","category-fernsteuerung","category-hybrid-generator","category-smarthome","category-smarthome-im-wohnmobil","category-smarthome-programme-erstellen","category-smarthome-raspberry-pi","category-stromerzeugung","tag-4-fach-schaltaktor","tag-aio-creator","tag-anlasser","tag-choke","tag-fernsteuerung","tag-generator","tag-generatorstart","tag-geraeuschkapselung","tag-homematic","tag-hybrid-generator","tag-lpg-gas","tag-pwm","tag-pwm-vor-rueck-regler","tag-raspberry-pi","tag-raspberrymatic","tag-regler","tag-relais","tag-schluesselschalter","tag-schubstangenmotor","tag-smarthome","tag-visualisierung","tag-zuendung"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/posts\/3661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/comments?post=3661"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/posts\/3661\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/media?parent=3661"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/categories?post=3661"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/es\/wp-json\/wp\/v2\/tags?post=3661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}