{"id":11434,"date":"2025-10-07T17:09:47","date_gmt":"2025-10-07T17:09:47","guid":{"rendered":"https:\/\/csiag.eu\/?p=11434"},"modified":"2025-10-07T17:54:09","modified_gmt":"2025-10-07T17:54:09","slug":"uudelleensuunnittelu-alijakelu","status":"publish","type":"post","link":"https:\/\/csiag.eu\/fi\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/","title":{"rendered":"Alajakelulevyn uudelleensuunnittelu"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sis\u00e4llysluettelo<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/fi\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Durchgangsklemmen-Installationskasten\" >L\u00e4pivientip\u00e4\u00e4tteen asennusrasia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/fi\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Verteilerschrank\" >Jakelukaappi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/fi\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Leistungsmessung\" >Tehon mittaus<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lukuaika<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minuuttia<\/span><\/span>\n<p>Talon alijakokeskuksen uudelleensuunnittelu voi olla j\u00e4rkev\u00e4\u00e4 useissa eri tapauksissa: esimerkiksi silloin, kun s\u00e4hk\u00f6johdot uusitaan kokonaan tai kun vanha sulakej\u00e4rjestelm\u00e4 korvataan uudella, mahdollisesti RCD:ll\u00e4 (RCD:ll\u00e4) varustetulla j\u00e4rjestelm\u00e4ll\u00e4.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Durchgangsklemmen-Installationskasten\"><\/span>L\u00e4pivientip\u00e4\u00e4tteen asennusrasia<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Molemmissa tapauksissa vanhat kaapelit osoittautuvat liian lyhyiksi, mink\u00e4 vuoksi ne lyhennet\u00e4\u00e4n standardoituun sopivaan pituuteen ja asetetaan k\u00e4ytett\u00e4v\u00e4ksi jatkok\u00e4yt\u00f6ss\u00e4 oleviin kiskoihin, automaatteihin jne. esimerkiksi PHOENIX-CONTACT UT 2.5 BU -l\u00e4pivientiliittimien avulla.<\/p>\n\n\n\n<p>Jos kapasiteetit ovat suuremmat kuin 2,5 mm:n osalta<sup>2<\/sup>Jos johdotuksessa on k\u00e4ytett\u00e4v\u00e4 2,5 mm:n l\u00e4pivientiliittimi\u00e4, niit\u00e4 on k\u00e4ytett\u00e4v\u00e4 2,5 mm:n l\u00e4pivientiliittimien sijasta. Kaapelointi on my\u00f6s suunniteltava vaadittujen poikkileikkausten mukaiseksi.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"900\" height=\"511\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_.png\" alt=\"\" class=\"wp-image-11436\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_.png 900w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-300x170.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-768x436.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-18x10.png 18w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n<p>Asennusta erilliseen, leve\u00e4\u00e4n 1-riviseen jakokeskukseen suositellaan, jos uusi jakokeskus on kapeampi kuin edellinen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verteilerschrank\"><\/span>Jakelukaappi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Jakokaapin koko riippuu asennettavista lis\u00e4komponenteista. Kolmivaiheisissa j\u00e4rjestelmiss\u00e4 siin\u00e4 on oltava 4 rivi\u00e4.<\/p>\n\n\n\n<p>Ensimm\u00e4ist\u00e4 rivi\u00e4 k\u00e4ytet\u00e4\u00e4n 5-napaisen p\u00e4\u00e4johdon haaraliittimen (kolme vaihetta, nollajohdin ja maadoitusjohdin), 3-napaisen p\u00e4\u00e4kytkimen (kolmea vaihetta varten) ja 4-napaisen suojakytkimen (nollajohdinta ja kolmea vaihetta varten) asentamiseen. Seuraavat kolme rivi\u00e4 on osoitettu kolmelle vaiheelle ja varustettu asianmukaisilla katkaisijoilla.<\/p>\n\n\n\n<p>Tavallisesti kaikki kaapelit tulevat ylh\u00e4\u00e4lt\u00e4. Joissakin asennustilanteissa kaapelit voivat tulla jakelukoteloon my\u00f6s alhaalta.<br>Jotta v\u00e4ltett\u00e4isiin kaikkien kaapeleiden johtaminen automaattien rivien takaa yl\u00e4kertaan (mik\u00e4 on yleens\u00e4 hankalaa jo pelk\u00e4st\u00e4\u00e4n DIN-kiskojen takana olevan rajallisen tilan vuoksi), kolmen viimeisen rivin lopussa on my\u00f6s l\u00e4pivientiliittimi\u00e4, joista kaapelit voidaan johtaa k\u00e4tev\u00e4sti yl\u00f6sp\u00e4in reunaa pitkin.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"510\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-510x1024.png\" alt=\"\" class=\"wp-image-11437\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-510x1024.png 510w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-149x300.png 149w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-6x12.png 6w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler.png 600w\" sizes=\"(max-width: 510px) 100vw, 510px\" \/><\/figure>\n<\/div>\n\n\n<p>Ja valmis jakelu ...<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"433\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-433x1024.png\" alt=\"\" class=\"wp-image-11448\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-433x1024.png 433w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-127x300.png 127w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-5x12.png 5w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl.png 600w\" sizes=\"(max-width: 433px) 100vw, 433px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leistungsmessung\"><\/span>Tehon mittaus<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Jos et halua vain lukea kokonaiskulutusta mittarista, vaan haluat my\u00f6s selvitt\u00e4\u00e4 kulutuksesi vaiheittain, voit k\u00e4ytt\u00e4\u00e4 erilaisia laitteita, jotka kattavat monenlaisia sovelluksia ja n\u00e4ytt\u00e4v\u00e4t tiedot k\u00e4tev\u00e4sti sovelluksen kautta.<\/p>\n\n\n\n<p>T\u00e4llaisia laitteita ei kuitenkaan k\u00e4ytet\u00e4 pelk\u00e4st\u00e4\u00e4n selkeyden vuoksi, vaan erityisesti siksi, ett\u00e4 yksitt\u00e4isten vaiheiden k\u00e4ytt\u00f6 on pitk\u00e4lti tasaista.<\/p>\n\n\n\n<p>Jos haluat k\u00e4sitell\u00e4 tietoja edelleen tai esimerkiksi vaihtaa kuluttajia, kuten ajoneuvon latausprosessia, tiettyin\u00e4 aikoina ja vaihekohtaisen k\u00e4yt\u00f6n mukaan, sinun on varmistettava, ett\u00e4 laite mahdollistaa my\u00f6s integroinnin t\u00e4llaisiin \u00e4lykoteihin ja ett\u00e4 tarvittava protokolla, kuten Shelly-tuotteet, on tuettu.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"712\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1024x712.png\" alt=\"\" class=\"wp-image-11438\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1024x712.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-300x208.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-768x534.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1536x1067.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-2048x1423.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-18x12.png 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>T\u00e4st\u00e4 laitteesta on saatavana kaksi versiota: \"T\" tarkoittaa p\u00e4\u00e4teyhteit\u00e4, jotka on tarkoitettu asennettavaksi suoraan RCD:hen. \"W\"-vaihtoehdossa on sen sijaan kaapeli, jossa on kaapelin p\u00e4\u00e4tykorvakkeet kutakin pistorasiaa varten.<\/p>\n\n\n\n<p>Molemmat tallentavat kulutuksen ja sy\u00f6t\u00f6n yht\u00e4 lailla induktiivisten antureiden avulla, jotka on sijoitettu RCD:n verkkomitan mukaiseen koteloon.<\/p>\n\n\n\n<p>Asennuksen aikana on huomioitava virran kulkusuunta, jotta ei rekister\u00f6id\u00e4 tuottoja, jotka pit\u00e4isi todellisuudessa kohdistaa kulutuspuolelle ... - N\u00e4in ollen \"L\" tarkoittaa kulutuspuolta, \"K\" sy\u00f6tt\u00f6-\/sy\u00f6tt\u00f6puolta (PV).<\/p>\n\n\n\n<p>Kukin vaihe on kytketty kolmeen pistotulppakoskettimeen kolmella kaapelikoskettimella, ja my\u00f6s nollajohdin on kytketty.<br>Vaiheet on suojattava nopeatoimisilla 100 mA:n 20 \u00d7 5 mm:n lasisulakkeilla, jotka on sijoitettu asianmukaisiin sulakkeenpitimiin. On kuulemma k\u00e4ynyt niin, ett\u00e4 t\u00e4llainen laite on pikkuhiljaa syttynyt tuleen ...<\/p>\n\n\n\n<p>Laitteen k\u00e4ytt\u00f6\u00f6notto on todella helppoa. K\u00e4ytt\u00e4m\u00e4ll\u00e4 sovellusta, jonka voi ladata QR-koodilla asiaankuuluvasta sovelluskaupasta, muodostat yhteyden laitteeseen Bluetoothin kautta, joka tunnistetaan v\u00e4litt\u00f6m\u00e4sti. T\u00e4m\u00e4n j\u00e4lkeen tarjotaan yhteys paikalliseen WLAN-verkkoon. Kun asiaankuuluvat turvallisuuskyselyt on hyv\u00e4ksytty, laite yhdistyy kodin WLAN-verkkoon, ja sit\u00e4 voi k\u00e4ytt\u00e4\u00e4 siit\u00e4 l\u00e4htien.<\/p>\n\n\n\n<p>Sovelluksen kulutustietojen n\u00e4ytt\u00f6 on selke\u00e4, joskaan ei n\u00e4ytt\u00e4v\u00e4sti suunniteltu.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"989\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1024x989.png\" alt=\"\" class=\"wp-image-11439\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1024x989.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-300x290.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-768x742.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1536x1484.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-2048x1979.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-12x12.png 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-text-align-center\">Kaikki tiedot ilman takuuta - s\u00e4hk\u00f6j\u00e4rjestelmien asennukset saa suorittaa vain valtuutettu asiantuntijahenkil\u00f6st\u00f6!<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lukuaika<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minuuttia<\/span><\/span>Eine Unterverteilung im Haus neu zu gestalten kann im verschiedenen F\u00e4llen sinnvoll sein: so z.B. bei einer vollst\u00e4ndigen Erneuerung der elektrischen Verkabelung oder auch, um eine alte Sicherungsanlage durch eine neue ggf. mit FI-Schalter(n) zu ersetzen. Durchgangsklemmen-Installationskasten In beiden F\u00e4llen erweisen sich die alten Kabel als zu kurz, weshalb man diese auf eine einheitlich passende&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/fi\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/\" rel=\"bookmark\">Lue lis\u00e4\u00e4 \"<span class=\"screen-reader-text\">Alajakelulevyn uudelleensuunnittelu<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1],"tags":[5494,551,5488,5490,5489,5486,5485,5484,5497,813,5482,5493,5088,389,5487,812,5498,5495,5496,1062,981,370,5481,3388,2621,2536,5483,563],"class_list":["post-11434","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-auslastung","tag-bt","tag-durchgangsklemmen","tag-einspeisedaten","tag-einspeisung","tag-fehlerstromschutzschalter","tag-fi-schalter-2","tag-galssicherung","tag-hauptleitungs-abzweigklemme","tag-installation","tag-installationskasten","tag-ladevorgang","tag-last","tag-leistungsmessung","tag-phoenix-contact","tag-photovoltaik","tag-pv","tag-shelly","tag-shelly-gen3","tag-sicherung","tag-sicherungsautomat","tag-smarthome","tag-unterverteilung","tag-verbrauch","tag-verbrauchsdaten","tag-verteiler","tag-verteilerschrank","tag-wlan"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts\/11434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/comments?post=11434"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts\/11434\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/media?parent=11434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/categories?post=11434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/tags?post=11434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}