{"id":2632,"date":"2022-12-03T15:06:30","date_gmt":"2022-12-03T15:06:30","guid":{"rendered":"https:\/\/csiag.eu\/?p=2632"},"modified":"2022-12-29T17:07:58","modified_gmt":"2022-12-29T17:07:58","slug":"hm_lss-maeaerittaeae-kuormituksesta-riippuvat-kytkentaekynnykset","status":"publish","type":"post","link":"https:\/\/csiag.eu\/fi\/blog\/2022\/12\/03\/hm_lss-lastabhaengige-schaltschwellen-festlegen\/","title":{"rendered":"HG_LM - Kuormasta riippuvien kytkent\u00e4kynnysten asettaminen"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lukuaika<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minuuttia<\/span><\/span>\n<p class=\"wp-block-paragraph\">Kuormituksesta riippuvan kytkent\u00e4kynnyksen tarkoituksena on v\u00e4ltt\u00e4\u00e4 maas\u00e4hk\u00f6\u00e4 sy\u00f6tt\u00e4v\u00e4n linjan ylikuormittuminen. Kun otetaan huomioon suurin sallittu teho, jonka oletetaan olevan 3 100 W, ja ALDE:n suurin s\u00e4hk\u00f6l\u00e4mmitysteho, joka on 1 500 W (vaihe I -&gt; 1 000 W, vaihe II -Y 500 W), t\u00e4m\u00e4 johtaa noin 1 600 W:n marginaaliin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ohjelma:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"246\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-1024x246.png\" alt=\"\" class=\"wp-image-2789\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-1024x246.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-300x72.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-768x184.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-1536x369.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-2048x492.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2022\/12\/image-22-1560x375.png 1560w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Ohjelma - HG_LM - Tehon mittaus ja tehoon liittyv\u00e4t kytkenn\u00e4t<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Koodi:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>real pwr = dom.GetObject(\"HG_LM_POWER\").Value(); WriteLine(\"Pwr.\");WriteLine(pwr);<br>var nicht_heizen = dom.GetObject(\"SV_IT\").Value(); WriteLine(\"nicht_heizen\");WriteLine(nicht_heizen);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>if ((pwr &gt; 1) &amp;&amp; (pwr &lt; 2201) &amp;&amp; (not_heating == false)))<br>{<br>dom.GetObject(\"BidCos-RF.IEQ0101895:1.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:2.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:3.STATE\").State(1);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>dom.GetObject(\"BidCos-RF.SEQ3114635:1.STATE\").State(1);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>var P = \"P &gt; 1 &lt; 2201&quot;; dom.GetObject(&quot;Current_Load&quot;).State(P);WriteLine(P);<br>}<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>elseif ((pwr &gt; 2200) &amp;&amp; (pwr &lt; 2601) &amp;&amp; (not_heating == false)))<br>{<br>dom.GetObject(\"BidCos-RF.IEQ0101895:1.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:2.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:3.STATE\").State(0);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>dom.GetObject(\"BidCos-RF.SEQ3114635:1.STATE\").State(1);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>var P = \"P &gt; 2200 &lt; 2601&quot;; dom.GetObject(&quot;Current_Load&quot;).State(P);WriteLine(P);<br>}<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>elseif ((pwr &gt; 2600) &amp;&amp; (pwr &lt; 2801) &amp;&amp; (not_heating == false)))<br>{<br>dom.GetObject(\"BidCos-RF.IEQ0101895:1.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:2.STATE\").State(0);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:3.STATE\").State(1);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>dom.GetObject(\"BidCos-RF.SEQ3114635:1.STATE\").State(1);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>var P = \"P &gt; 2600 &lt; 2801&quot;; dom.GetObject(&quot;Current_Load&quot;).State(P);WriteLine(P);<br>}<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>elseif ((pwr &gt; 2800) &amp;&amp; (pwr &lt; 3101) &amp;&amp; (not_heating == false)))<br>{<br>dom.GetObject(\"BidCos-RF.IEQ0101895:1.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:2.STATE\").State(0);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:3.STATE\").State(1);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>dom.GetObject(\"BidCos-RF.SEQ3114635:1.STATE\").State(0);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>! var P = \"P &gt; 2800 &lt; 3101&quot;; dom.GetObject(&quot;Current_Load&quot;).State(P);WriteLine(P);<br>}<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>elseif (pwr &gt; 3100)<br>{<\/code><br><code>dom.GetObject(\"BidCos-RF.IEQ0101895:1.STATE\").State(1);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:2.STATE\").State(0);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:3.STATE\").State(0);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>dom.GetObject(\"BidCos-RF.SEQ3114635:1.STATE\").State(0);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>var P = \"P &gt; 3100\"; dom.GetObject(\"Current_Load\").State(P);WriteLine(P);<br>}<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>elseif (not_heating == true)<br>{<br>dom.GetObject(\"BidCos-RF.IEQ0101895:1.STATE\").State(0);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:2.STATE\").State(0);<br>dom.GetObject(\"BidCos-RF.IEQ0101895:3.STATE\").State(0);<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>dom.GetObject(\"BidCos-RF.SEQ3114635:1.STATE\").State(1);<br>}<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Skriptin tuloste (jos rivit <code>WriteLine(\" ... \")<\/code> ei ole kommentoitu pois):<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>Pwr.<br>1882.919998<br>not_heating<br>v\u00e4\u00e4r\u00e4<br>P &gt; 1 &lt; 2201<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Skripti arvioi j\u00e4rjestelm\u00e4muuttujan <code>HG_LM_POWER<\/code> edellisest\u00e4 k\u00e4sikirjoituksesta sek\u00e4 l\u00e4mmityspumppua kytkev\u00e4n Homematic 4-kertaisen relemoduulin kanavan 1 tila. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Jos tehoreservi on riitt\u00e4v\u00e4, esim. alle 2 301 W, pumpun tila ilmoitetaan seuraavasti <code>1<\/code> joten j\u00e4rjestelm\u00e4muuttuja <code>not_heating<\/code> = <code>v\u00e4\u00e4r\u00e4<\/code>sitten, mukaan <code>jos<\/code>-Haarataso I ja II kytketty p\u00e4\u00e4lle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Jos esimerkiksi kahvinkeitin on nyt aktivoitu, tarvitaan 800 W lis\u00e4\u00e4. Aiemmasta 2 131,7 W:n tehosta tulee 2 931,7 W.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4n seurauksena toinen <code>elseif<\/code>-haara ja vaihe I on kytketty pois p\u00e4\u00e4lt\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kun kahvinkeitin kytket\u00e4\u00e4n uudelleen pois p\u00e4\u00e4lt\u00e4, tehontarve v\u00e4henee edelliselle tasolle ja taso I kytkeytyy j\u00e4lleen p\u00e4\u00e4lle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Muut skenaariot toimivat samalla tavalla.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lukuaika<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minuuttia<\/span><\/span>Kuormituksesta riippuvan kytkent\u00e4kynnyksen tarkoituksena on v\u00e4ltt\u00e4\u00e4 maas\u00e4hk\u00f6\u00e4 sy\u00f6tt\u00e4v\u00e4n linjan ylikuormittuminen. Kun otetaan huomioon suurin sallittu teho, jonka oletetaan olevan 3 100 W, ja ALDE:n suurin s\u00e4hk\u00f6l\u00e4mmitysteho, joka on 1 500 W (taso I -&gt; 1 000 W, taso II -Y 500 W), saadaan noin 1 600 W:n marginaali. Ohjelma: Koodi: real pwr = dom.GetObject(\"HG_LM_POWER\").Value(); WriteLine(\"Pwr.\");WriteLine(pwr);var...&nbsp;<a href=\"https:\/\/csiag.eu\/fi\/blog\/2022\/12\/03\/hm_lss-lastabhaengige-schaltschwellen-festlegen\/\" rel=\"bookmark\">Lue lis\u00e4\u00e4 \"<span class=\"screen-reader-text\">HG_LM - Kuormasta riippuvien kytkent\u00e4kynnysten asettaminen<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[450,346,347],"tags":[452,451,453,389,454,391],"class_list":["post-2632","post","type-post","status-publish","format-standard","hentry","category-leistungsmessung","category-smarthome","category-smarthome-im-wohnmobil","tag-heizleistung","tag-lastabhaengig","tag-leistungsbedarf","tag-leistungsmessung","tag-leistungsreserve","tag-schaltschwelle"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts\/2632","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/comments?post=2632"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts\/2632\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/media?parent=2632"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/categories?post=2632"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/tags?post=2632"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}