{"id":4026,"date":"2023-04-13T09:01:13","date_gmt":"2023-04-13T09:01:13","guid":{"rendered":"https:\/\/csiag.eu\/?p=4026"},"modified":"2023-04-18T09:31:39","modified_gmt":"2023-04-18T09:31:39","slug":"victron-gx-saeilioe-140","status":"publish","type":"post","link":"https:\/\/csiag.eu\/fi\/blog\/2023\/04\/13\/victron-gx-tank-140\/","title":{"rendered":"Victron GX-s\u00e4ili\u00f6 140"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sis\u00e4llysluettelo<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/fi\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Sensor-Ausgang_CBE\" >Anturin ulostulo (CBE)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/fi\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Sensor-Eingang_GX_Tank_140\" >Anturitulo (GX-s\u00e4ili\u00f6 140)<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/fi\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Verkabelung\" >Kaapelointi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/fi\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Konfiguration\" >Konfigurointi<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lukuaika<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minuuttia<\/span><\/span>\n<p class=\"wp-block-paragraph\">Victronin GX Tank 140 mahdollistaa jopa nelj\u00e4n s\u00e4ili\u00f6anturin liitt\u00e4misen, joissa on virta- tai j\u00e4nniteohjattu mittausl\u00e4ht\u00f6, sek\u00e4 CBE:n j\u00e4nniteohjattujen antureiden liitt\u00e4misen, joita asennetaan hyvin usein matkailuautoihin.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sensor-Ausgang_CBE\"><\/span>Anturin ulostulo (CBE)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ruskea (GND -)<\/li>\n\n\n\n<li>valkoinen (V +)<\/li>\n\n\n\n<li>vihre\u00e4 (signaali V out +)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sensor-Eingang_GX_Tank_140\"><\/span>Anturitulo (GX-s\u00e4ili\u00f6 140)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 - valkoinen (V out +)<\/li>\n\n\n\n<li>2 - vihre\u00e4 (signaali IN +)<\/li>\n\n\n\n<li>3 - ruskea (GND -)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verkabelung\"><\/span>Kaapelointi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Anturin kytkeminen GX Tank 140:n vastaavaan liit\u00e4nt\u00e4ryhm\u00e4\u00e4n: - Kytke anturi GX Tank 140:n liit\u00e4nt\u00e4ryhm\u00e4\u00e4n. <a href=\"https:\/\/www.amazon.de\/dp\/B0BGY8D4WP?psc=1&amp;ref=ppx_yo2ov_dt_b_product_details\" target=\"_blank\" rel=\"noreferrer noopener\">Valvontalinja<\/a> LiYCY-suojattu 4 x 0,25 mm<sup>2<\/sup> suositeltava. Jos mahdollista, kaapelireitti olisi valittava siten, ett\u00e4 se on samansuuntainen kuin olemassa olevat kaapelit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Huomaa, ett\u00e4 ulkoinen virtal\u00e4hde, joka on analoginen k\u00e4ytett\u00e4vien antureiden virtal\u00e4hteeseen, on kytkett\u00e4v\u00e4 antureiden vasemmanpuoleiseen kaksinapaiseen liitinlohkoon liitinlohkoissa I ja II (esim. 5 V tai 12 V DC).<br>P\u00e4\u00e4telohkoihin II ja IV puolestaan sy\u00f6tet\u00e4\u00e4n sis\u00e4isesti 24 V DC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kytkent\u00e4 tehd\u00e4\u00e4n 1:1, eli GX Tank 140:n liitinlohkossa I liit\u00e4nt\u00e4 1 on ensimm\u00e4inen vasemmalta valkoisella kaapelilla, keskell\u00e4 vihre\u00e4ll\u00e4 ja oikealla ruskealla kaapelilla. Sama kytkent\u00e4j\u00e4rjestys p\u00e4tee lohkoihin II ... IV edellytt\u00e4en, ett\u00e4 kytket\u00e4\u00e4n samanlaiset anturit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Konfiguration\"><\/span>Konfigurointi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kun Victron GX Tank 140 on liitetty Victron Cerbo GX:\u00e4\u00e4n kiinte\u00e4sti asennetun USB-kaapelin avulla, konfigurointi voidaan suorittaa Victron Cerbo GX:n kosketusn\u00e4yt\u00f6n kautta kohdassa <code>Asetukset<\/code> ja uudet laitemerkinn\u00e4t.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6.png\" alt=\"\" class=\"wp-image-4072\" width=\"407\" height=\"233\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6.png 976w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6-300x172.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6-768x441.png 768w\" sizes=\"(max-width: 407px) 100vw, 407px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Jos merkint\u00e4 <code>Yhdistetty<\/code> kanssa <code>Kyll\u00e4<\/code> l\u00f6ytyy osoitteesta <code>Nimi<\/code> anturi voidaan merkit\u00e4 yksil\u00f6llisell\u00e4 nimell\u00e4. Voit siirty\u00e4 yhden tason taaksep\u00e4in napsauttamalla vasemmassa yl\u00e4kulmassa olevaa nuolta.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8.png\" alt=\"\" class=\"wp-image-4074\" width=\"406\" height=\"232\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8.png 976w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8-300x172.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8-768x439.png 768w\" sizes=\"(max-width: 406px) 100vw, 406px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Valikkokohdan <code>Setup<\/code> muut asetukset voidaan tehd\u00e4:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-9.png\" alt=\"\" class=\"wp-image-4075\" width=\"408\" height=\"379\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-9.png 540w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-9-300x279.png 300w\" sizes=\"(max-width: 408px) 100vw, 408px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Kohde <code>Anturin arvo<\/code>. Jos s\u00e4ili\u00f6 on osittain t\u00e4ynn\u00e4, t\u00e4ss\u00e4 pit\u00e4isi n\u00e4ky\u00e4 j\u00e4nnitteen arvo. Jos n\u00e4yt\u00f6ss\u00e4 n\u00e4kyy 0,0 V, joko anturiliit\u00e4nt\u00e4 tai 5 V:n virtal\u00e4hde ei ole k\u00e4yt\u00f6ss\u00e4.<br>Kaksinapainen 5 V:n liitinlohko n\u00e4ytt\u00e4\u00e4 aiheuttavan ajoittain kosketusongelmia. T\u00e4m\u00e4n tarkistamiseksi on tarkistettava, ett\u00e4 p\u00e4\u00e4tepylv\u00e4\u00e4seen kytketty kaapeli on jatkuvuudeltaan kunnossa ennen sen kytkemist\u00e4 virtal\u00e4hteeseen.<br>Positiivisessa liit\u00e4nn\u00e4ss\u00e4 on vastus V<sub>out<\/sub>-yhteydet. Miinusjohtimella on jatkuvuus kaikissa muissa GND-liit\u00e4nn\u00f6iss\u00e4. Jos t\u00e4ss\u00e4 kohdassa havaitaan katkos, vastaava kaapeli on irrotettava liitinlohkosta, kuorittava tarvittaessa pidemm\u00e4ksi ja kytkett\u00e4v\u00e4 uudelleen tai kytkett\u00e4v\u00e4 suurempi johtimen poikkipinta-ala, jonka poikkipinta-ala on 0,5 .... 0,75 mm<sup>2<\/sup> k\u00e4ytt\u00e4\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Seuraavat toimet on aina lopetettava <code>S\u00e4ili\u00f6n tilavuus<\/code> ja <code>T\u00e4ytt\u00f6v\u00e4line<\/code>ja j\u00e4nnitearvo, kun s\u00e4ili\u00f6 on t\u00e4ynn\u00e4 (vastaa yleens\u00e4 anturin sy\u00f6tt\u00f6j\u00e4nnitett\u00e4).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4ll\u00f6in t\u00e4ytt\u00f6tasot n\u00e4kyv\u00e4t yleiskatsauksessa seuraavasti:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-10.png\" alt=\"\" class=\"wp-image-4076\" width=\"122\" height=\"83\"\/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lukuaika<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minuuttia<\/span><\/span>Victronin GX Tank 140 mahdollistaa jopa nelj\u00e4n s\u00e4ili\u00f6anturin liitt\u00e4misen, joissa on virta- tai j\u00e4nniteohjattu mittausl\u00e4ht\u00f6, sek\u00e4 CBE:n j\u00e4nniteohjattujen antureiden liitt\u00e4misen, joita asennetaan hyvin usein matkailuautoihin. Anturin l\u00e4ht\u00f6 (CBE) Anturin tulo (GX Tank 140) Johdotus Anturi liitet\u00e4\u00e4n suojattua LiYCY-ohjauskaapelia k\u00e4ytt\u00e4en GX Tank 140:n vastaavaan liitinlohkoon.&nbsp;<a href=\"https:\/\/csiag.eu\/fi\/blog\/2023\/04\/13\/victron-gx-tank-140\/\" rel=\"bookmark\">Lue lis\u00e4\u00e4 \"<span class=\"screen-reader-text\">Victron GX-s\u00e4ili\u00f6 140<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4026","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts\/4026","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/comments?post=4026"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/posts\/4026\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/media?parent=4026"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/categories?post=4026"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/fi\/wp-json\/wp\/v2\/tags?post=4026"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}