{"id":11143,"date":"2025-09-15T11:21:28","date_gmt":"2025-09-15T11:21:28","guid":{"rendered":"https:\/\/csiag.eu\/?p=11143"},"modified":"2025-09-15T11:31:02","modified_gmt":"2025-09-15T11:31:02","slug":"halozati-technologia-kapcsolok-es-kabelezes","status":"publish","type":"post","link":"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/","title":{"rendered":"H\u00e1l\u00f3zati technol\u00f3gia - kapcsol\u00f3k \u00e9s k\u00e1belez\u00e9s"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Tartalomjegyz\u00e9k<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Netzwerk-Kabel\" >H\u00e1l\u00f3zati k\u00e1bel<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Abschirmung\" >\u00c1rny\u00e9kol\u00e1s<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Klassifizierung_CAT\" >Oszt\u00e1lyoz\u00e1s (CAT)<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Glasfaser_vs_Kupfer\" >Sz\u00e1loptika vs. r\u00e9z<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Preisfrage\" >\u00c1r k\u00e9rd\u00e9s<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Hub_vs_Switch\" >Hub vs. switch<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Hub\" >Stroke<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Switch\" >Switch<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Ports\" >Kik\u00f6t\u0151k<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Switches_%E2%80%93_unmanaged\" >Kapcsol\u00f3k - (nem) menedzselt<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Hersteller_von_Switches\" >Kapcsol\u00f3k gy\u00e1rt\u00f3ja<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Cisco\" >Cisco<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Ubiquiti\" >Ubiquiti<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Olvas\u00e1si id\u0151<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">percek<\/span><\/span>\n<p>A kapcsol\u00f3k \u00e9s a k\u00e1belez\u00e9s k\u00f6zponti szerepet j\u00e1tszanak a h\u00e1l\u00f3zati technol\u00f3gi\u00e1ban. A k\u00fcl\u00f6nbs\u00e9geket \u00e9s a figyelembe veend\u0151 kiv\u00e1laszt\u00e1si krit\u00e9riumokat az al\u00e1bbiakban t\u00e1rgyaljuk.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Netzwerk-Kabel\"><\/span>H\u00e1l\u00f3zati k\u00e1bel<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Abschirmung\"><\/span>\u00c1rny\u00e9kol\u00e1s<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A h\u00e1l\u00f3zati k\u00e1beleket 4 p\u00e1ros sodrott egyp\u00e1ras k\u00e1belk\u00e9nt tervezt\u00e9k, k\u00f6z\u00f6s r\u00e9zfonattal a k\u00fcls\u0151 zavar\u00f3 mez\u0151k \u00e1rny\u00e9kol\u00e1s\u00e1ra (S\/FTP - <em><strong>S<\/strong>kreened <strong>F<\/strong>olajozott <strong>T<\/strong>wisted <strong>P<\/strong>air<\/em>). A csavar\u00e1s kik\u00fcsz\u00f6b\u00f6li a bels\u0151 interferenciamez\u0151ket.<br>A fonott \u00e1rny\u00e9kol\u00e1ssal ell\u00e1tott egyedi vezet\u00e9kp\u00e1rokkal ell\u00e1tott k\u00e1beleket S\/STP k\u00e1beleknek nevezik (<em><strong>S<\/strong>kreened <strong>S<\/strong>hielded <strong>T<\/strong>wisted<strong> P<\/strong>air<\/em>). <br>FTP-k\u00e1belek eset\u00e9n (<em><em><strong>F<\/strong>olajozott <strong>T<\/strong>wisted <strong>P<\/strong>air<\/em><\/em>), a r\u00e9zfonat helyett alum\u00edniummal bevont f\u00f3li\u00e1t haszn\u00e1lnak.<br>Minden v\u00e1ltozatban egy \u00fagynevezett leereszt\u0151 vezet\u00e9k szolg\u00e1l f\u00f6ldel\u0151 vezet\u00e9kk\u00e9nt.<\/p>\n\n\n\n<p>UTP k\u00e1belek (<em><strong>U<\/strong>nshielded <strong>T<\/strong>wisted <strong>P<\/strong>air<\/em>), amelyek nem rendelkeznek \u00e1rny\u00e9kol\u00e1ssal, \u00e9s ez\u00e9rt nem rendelkeznek k\u00e9tvezet\u00e9kes kapcsolattal.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Klassifizierung_CAT\"><\/span>Oszt\u00e1lyoz\u00e1s (CAT)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A CAT1-CAT6(A) kateg\u00f3ri\u00e1k nem tartoznak ide, mivel ezek m\u00e1r nem felelnek meg a mai s\u00e1vsz\u00e9less\u00e9gi k\u00f6vetelm\u00e9nyeknek, ha 10 Gbit\/s vagy magasabb Ethernetre van sz\u00fcks\u00e9g.<\/p>\n\n\n\n<p>A CAT7-t\u0151l a vezet\u00e9kp\u00e1rok k\u00fcl\u00f6n-k\u00fcl\u00f6n \u00e1rny\u00e9kolva vannak. Megfelelnek az al\u00e1bbi k\u00f6vetelm\u00e9nyeknek <a href=\"https:\/\/de.wikipedia.org\/wiki\/IEEE_802.3an\" target=\"_blank\" rel=\"noopener\">IEEE 802.3an<\/a>600 MHz-ig, a CAT7A 1000 MHz-ig \u00e9s 10GBASE-T alkalmaz\u00e1sokban ak\u00e1r 10 Gbit\/s adat\u00e1tviteli sebess\u00e9ggel is haszn\u00e1lhat\u00f3.<br>A k\u00e1bel maxim\u00e1lis hossza 100 m a n\u00e9vleges \u00e1tviteli sebess\u00e9g mellett.<\/p>\n\n\n\n<p>A legnagyobb adat\u00e1tviteli sebess\u00e9get jelenleg a CAT8.2 kateg\u00f3ri\u00e1j\u00fa k\u00e1belek \u00e9rik el, amelyek s\u00e1vsz\u00e9less\u00e9ge 2 Gbit\/s, illetve 40 Gbit\/s a 25 GBASE-T \u00e9s 40 GBASE-T alkalmaz\u00e1sok eset\u00e9ben.<br>A 40GBASE-T eset\u00e9ben a k\u00e1bel hossza 30 m\u00e9terre korl\u00e1toz\u00f3dik.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Glasfaser_vs_Kupfer\"><\/span>Sz\u00e1loptika vs. r\u00e9z<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A r\u00e9zk\u00e1belek, k\u00fcl\u00f6n\u00f6sen a CAT8 k\u00e1belek teljes\u00edtm\u00e9nye ma m\u00e1r \u00f6sszehasonl\u00edthat\u00f3 az optikai sz\u00e1lak\u00e9val. Mindazon\u00e1ltal van egy k\u00fcl\u00f6nbs\u00e9g, amely csak r\u00e9zzel val\u00f3s\u00edthat\u00f3 meg, nevezetesen a PoE (<em><strong>P<\/strong>ower <strong>o<\/strong>ver <strong>E<\/strong>thernet<\/em>), a fogyaszt\u00f3k, p\u00e9ld\u00e1ul a kamer\u00e1k \u00e1ramell\u00e1t\u00e1sa az Ethernet-k\u00e1belen kereszt\u00fcl.<\/p>\n\n\n\n<p>Ha nincs sz\u00fcks\u00e9g PoE-re, a trend az optikai sz\u00e1lak fel\u00e9 mutat, b\u00e1r a kezel\u00e9s, p\u00e9ld\u00e1ul a csatlakoz\u00f3k \u00f6sszeszerel\u00e9se sokkal bonyolultabb, \u00e9s speci\u00e1lis szersz\u00e1mokra van sz\u00fcks\u00e9g.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Preisfrage\"><\/span>\u00c1r k\u00e9rd\u00e9s<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A CAT7(A) \u00e9s a CAT8(.1\/.2) k\u00f6z\u00f6tti \u00e1rk\u00fcl\u00f6nbs\u00e9g a 10% eset\u00e9ben margin\u00e1lis. A 3 m-es CAT7-es k\u00e1bel\u00e9rt k\u00f6r\u00fclbel\u00fcl 10 eur\u00f3t, a CAT8.1-es\u00e9rt pedig k\u00f6r\u00fclbel\u00fcl 11 eur\u00f3t kell fizetni.<br>Fontos azonban megjegyezni, hogy az infrastrukt\u00far\u00e1nak, p\u00e9ld\u00e1ul a kapcsol\u00f3knak is meg kell felelni\u00fck a besorol\u00e1si k\u00f6vetelm\u00e9nyeknek, ha nem akarnak az adat\u00e1raml\u00e1s sz\u0171k keresztmetszet\u00e9v\u00e9 v\u00e1lni.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hub_vs_Switch\"><\/span>Hub vs. switch<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A k\u00f6zpontok \u00e9s kapcsol\u00f3k arra szolg\u00e1lnak, hogy a bej\u00f6v\u0151 adatfolyamot - p\u00e9ld\u00e1ul az \u00fatv\u00e1laszt\u00f3r\u00f3l - a rendelkez\u00e9sre \u00e1ll\u00f3 portkapcsolatokon kereszt\u00fcl a v\u00e9gberendez\u00e9sek, p\u00e9ld\u00e1ul sz\u00e1m\u00edt\u00f3g\u00e9pek, nyomtat\u00f3k, szkennerek, kamer\u00e1k vagy m\u00e1s h\u00e1l\u00f3zati eszk\u00f6z\u00f6k fel\u00e9 terjessz\u00e9k.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hub\"><\/span>Stroke<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A hub egyenletesen osztja el a bej\u00f6v\u0151 adatfolyamot az \u00f6sszes porton. A csatlakoztatott el\u0151fizet\u0151k fogadj\u00e1k az adatfolyamot.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Switch\"><\/span>Switch<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A kapcsol\u00f3 elemzi a fogadott adatfolyam fejl\u00e9c\u00e9t. A felismert MAC-c\u00edm hat\u00e1rozza meg a c\u00e9lk\u00e9sz\u00fcl\u00e9ket. Ha a MAC-c\u00edm nincs felismerve, akkor az adatcsomagot az \u00f6sszes portra elk\u00fcldi. Amint a megfelel\u0151 c\u00e9leszk\u00f6z v\u00e1laszol, tov\u00e1bb\u00edtja a MAC-c\u00edm\u00e9t, amelyet a kapcsol\u00f3 ezut\u00e1n be\u00edr a CAM-ba (<em><strong>C<\/strong>ontent <strong>A<\/strong>\u00f6lt\u00f6zhet\u0151 <strong>M<\/strong>emory<\/em>), valamint SAT t\u00e1bl\u00e1zat (<em><strong>S<\/strong>ource-<strong>A<\/strong>ruha -<strong>T<\/strong>k\u00e9pes<\/em>) van megadva. Ez azt jelenti, hogy a csomagok azonnal tov\u00e1bb\u00edthat\u00f3k a megfelel\u0151 c\u00e9lc\u00edmre, mindenf\u00e9le ker\u00fcl\u0151\u00fat n\u00e9lk\u00fcl a MAC-c\u00edm seg\u00edts\u00e9g\u00e9vel.<br>A MAC-c\u00edmen kereszt\u00fcli k\u00f6zvetlen hozz\u00e1rendel\u00e9s megakad\u00e1lyozza az adatcsomagok k\u00f6z\u00f6tti \u00fctk\u00f6z\u00e9seket, \u00e9s lehet\u0151v\u00e9 teszi a teljes duplex kommunik\u00e1ci\u00f3t, ami optimaliz\u00e1lja az adat\u00e1tviteli teljes\u00edtm\u00e9nyt.<\/p>\n\n\n\n<p>A kapcsol\u00f3k virtu\u00e1lis LAN-okat is l\u00e9trehozhatnak (<em>VLAN<\/em>), \u00e9s az adatforgalmat k\u00fcl\u00f6nb\u00f6z\u0151 logikai h\u00e1l\u00f3zatokra osztj\u00e1k sz\u00e9t, \u00e9s \u00edgy egym\u00e1st\u00f3l elk\u00fcl\u00f6n\u00edtve dolgozz\u00e1k fel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ports\"><\/span>Kik\u00f6t\u0151k<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A portok sz\u00e1ma v\u00e1ltoz\u00f3, 4, 8, 16, 24 \u00e9s 48 port k\u00f6z\u00f6tt minden kaphat\u00f3 a piacon.<\/p>\n\n\n\n<p>Ez\u00e9rt el\u0151sz\u00f6r fel kell jegyzetelnie minden olyan eszk\u00f6zt, amelyet LAN-on kereszt\u00fcl csatlakoztat a switchhez.<\/p>\n\n\n\n<p>A PoE-n kereszt\u00fcl t\u00e1pl\u00e1land\u00f3 v\u00e9gberendez\u00e9sek eset\u00e9ben figyelembe kell venni az energiafogyaszt\u00e1st. Ennek oka, hogy az \u00f6sszes PoE-port \u00f6sszege hat\u00e1rozza meg a kapcsol\u00f3 t\u00e1pegys\u00e9g\u00e9nek sz\u00fcks\u00e9ges \u00f6sszteljes\u00edtm\u00e9ny\u00e9t - \u00e9s \u00edgy az \u00e1r\u00e1t is.<\/p>\n\n\n\n<p>Egy 16 portos switch p\u00e9ld\u00e1ul 12 nem PoE portot \u00e9s 4 PoE portot biztos\u00edt. Ez\u00e9rt fontos ellen\u0151rizni, hogy val\u00f3j\u00e1ban h\u00e1ny PoE port \u00e1ll rendelkez\u00e9sre - \u00e9s milyen teljes\u00edtm\u00e9ny\u0171.<\/p>\n\n\n\n<p>Tekintettel az \u00e1ltal\u00e1ban n\u00f6vekv\u0151 h\u00e1l\u00f3zati infrastrukt\u00far\u00e1ra, a portok \u00e9s a PoE portok sz\u00e1m\u00e1ban bizonyos tartal\u00e9kot kell k\u00e9pezni.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Switches_%E2%80%93_unmanaged\"><\/span>Kapcsol\u00f3k - (nem) menedzselt<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Sz\u00e1mos gy\u00e1rt\u00f3 osztozik a piacon. V\u00e9lem\u00e9nyem szerint mindig olyan gy\u00e1rt\u00f3t c\u00e9lszer\u0171 v\u00e1lasztani, amelyik az \u00fczleti szektorban tev\u00e9kenykedik, \u00e9s ez\u00e9rt komoly tapasztalattal rendelkezik ebben a piaci szegmensben.<\/p>\n\n\n\n<p>K\u00fcl\u00f6nbs\u00e9get kell tenni az \u00fan. <em>menedzselt<\/em> \u00e9s <em>nem kezelt<\/em> Kapcsol\u00f3k. Csak <em>menedzselt<\/em> A kapcsol\u00f3k konfigur\u00e1lhat\u00f3k. M\u00e9g ha a konfigur\u00e1lhat\u00f3s\u00e1g kezdetben ritk\u00e1n is fontos az egyes felhaszn\u00e1l\u00f3k sz\u00e1m\u00e1ra, mint az \u00e9letben \u00e1ltal\u00e1ban, az ig\u00e9ny id\u0151vel n\u00f6vekszik, \u00e9s a konfigur\u00e1ci\u00f3s lehet\u0151s\u00e9g ir\u00e1nti ig\u00e9ny el\u0151re l\u00e1that\u00f3v\u00e1 v\u00e1lik.<\/p>\n\n\n\n<p>A konfigur\u00e1ci\u00f3 egyszer\u0171s\u00e9ge cs\u00f6kken a professzionalizmus \u00e9s az ezzel j\u00e1r\u00f3 adminisztrat\u00edv bonyolults\u00e1g n\u00f6veked\u00e9s\u00e9vel.<\/p>\n\n\n\n<p>A kapcsol\u00f3 azonban mindig a gy\u00e1ri alapkonfigur\u00e1ci\u00f3ban \"m\u0171k\u00f6dik\". Ez azt jelenti, hogy - egyel\u0151re - nincs sz\u00fcks\u00e9g konfigur\u00e1l\u00e1si er\u0151fesz\u00edt\u00e9sre, b\u00e1r opcion\u00e1lis.<\/p>\n\n\n\n<p>Ebben a tekintetben most m\u00e1r lehet t\u00e1maszkodni <em>menedzselt<\/em> kapcsol\u00f3k.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hersteller_von_Switches\"><\/span>Kapcsol\u00f3k gy\u00e1rt\u00f3ja<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>V\u00e9lem\u00e9nyem szerint a v\u00e1laszt\u00e1s gy\u00f6trelme k\u00e9t gy\u00e1rt\u00f3ra reduk\u00e1l\u00f3dik. Akinek van affinit\u00e1sa a Cisco-hoz, az k\u00e9rd\u00e9s n\u00e9lk\u00fcl a Cisc\u00f3t fogja v\u00e1lasztani. Aki m\u00e9g nem elfogult, nem rendelkezik v\u00e9gtelen k\u00f6lts\u00e9gvet\u00e9ssel \u00e9s nem \u00fczleti szakember, ha h\u00e1l\u00f3zat\u00e9p\u00edt\u00e9sr\u0151l van sz\u00f3, az meg fogja tanulni \u00e9rt\u00e9kelni az Ubiquiti-t.<\/p>\n\n\n\n<p>Mindk\u00e9t gy\u00e1rt\u00f3 k\u00f6z\u00f6s jellemz\u0151je, hogy a nagyobb switchek (egyes esetekben 8 vagy 16 portt\u00f3l) \u00e1ltal\u00e1ban optikai csatlakoz\u00f3kat (SFP\/SFP+ 16 Gbit\/s-os vagy Enhanced Quad-Small Form-factor Pluggable 40 Gbit\/s-os (QSFP+)) biztos\u00edtanak, \u00e1ltal\u00e1ban 2 vagy 4 darab optikai csatlakoz\u00f3t.<br>A QSFP-DD (dupla s\u0171r\u0171s\u00e9g\u0171) ak\u00e1r 56 GBit\/s \u00e9s 400 Gbit\/s sebess\u00e9get is t\u00e1mogat.<\/p>\n\n\n\n<p>Az uplink portok maxim\u00e1lis k\u00e1belhossza a fenti szabv\u00e1nyok szerint 550 m (multim\u00f3d) vagy 10 km (szinglem\u00f3d LX), illetve 40 km (szinglem\u00f3d EX) \u00e9s 80 km (szinglem\u00f3d ZX), a sz\u00e1l t\u00edpus\u00e1t\u00f3l f\u00fcgg\u0151en. <\/p>\n\n\n\n<p>A CWDM \u00e9s DWDM modulok ak\u00e1r 80 vagy 120 km-es t\u00e1vols\u00e1gokat is lehet\u0151v\u00e9 tesznek, felt\u00e9ve, hogy rendelkez\u00e9sre \u00e1ll a megfelel\u0151 \u00e1tviteli teljes\u00edtm\u00e9ny \u00e9s v\u00e9teli \u00e9rz\u00e9kenys\u00e9g.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cisco\"><\/span>Cisco<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A Cisco val\u00f3sz\u00edn\u0171leg a legismertebb gy\u00e1rt\u00f3. A nem professzion\u00e1lis felhaszn\u00e1l\u00f3kat gyakran elriasztja az adminisztr\u00e1ci\u00f3, amely szinte minden lehet\u0151s\u00e9get lefed, \u00e9s ez\u00e9rt nagyon \u00f6sszetett. A professzion\u00e1lis k\u00f6rnyezetben a Cisco n\u00e9lk\u00fcl\u00f6zhetetlen \u00e9s kv\u00e1zi szabv\u00e1ny.<\/p>\n\n\n\n<p>SG \u00e9s a CBS (<em>Cisco Business Switch<\/em>) mag\u00e1nfelhaszn\u00e1l\u00f3kat, p\u00e9ld\u00e1ul kis- \u00e9s k\u00f6z\u00e9pv\u00e1llalkoz\u00e1sokat szolg\u00e1lnak ki, a Cisco Catalyst az ipari felhaszn\u00e1l\u00f3kat, a Cisco Nexus pedig a nagy sk\u00e1l\u00e1zhat\u00f3s\u00e1got \u00e9s megfelel\u0151 teljes\u00edtm\u00e9nyt ig\u00e9nyl\u0151 h\u00e1l\u00f3zati strukt\u00far\u00e1kat c\u00e9lozza.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ubiquiti\"><\/span>Ubiquiti<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Az Ubiquiti egy eredetileg a professzion\u00e1lis szektorban tev\u00e9kenyked\u0151 gy\u00e1rt\u00f3, amely nem csak kapcsol\u00f3k, hanem WLAN- \u00e9s r\u00e1di\u00f3s \u00e1tj\u00e1tsz\u00f3 komponensek gy\u00e1rt\u00e1s\u00e1val is foglalkozik, \u00e9s amely az \u00fczleti szektorb\u00f3l sz\u00e1rmaz\u00f3 professzion\u00e1lis technol\u00f3gi\u00e1val rendelkez\u0151 fogyaszt\u00f3i term\u00e9kcsal\u00e1dot k\u00edn\u00e1l megfizethet\u0151 \u00e1ron.<br>Jellemz\u0151je tov\u00e1bb\u00e1 a 24\/7 online RealTime t\u00e1mogat\u00e1s, amely a vez\u00e9rl\u0151 felhaszn\u00e1l\u00f3i fel\u00fclet\u00e9r\u0151l h\u00edvhat\u00f3, \u00e9s t\u00e1volr\u00f3l is csatlakoztathat\u00f3. A munkamenetnapl\u00f3k r\u00f6gz\u00edt\u00e9sre ker\u00fclnek, \u00e9s a munkamenet v\u00e9g\u00e9n e-mailben el\u00e9rhet\u0151v\u00e9 v\u00e1lnak. Ez lehet\u0151v\u00e9 teszi a l\u00e9p\u00e9sek ut\u00f3lagos r\u00e9szletes visszak\u00f6vet\u00e9s\u00e9t.<\/p>\n\n\n\n<p>Az UniFi \u00e9s az Edge a Ubiquiti \u00e1ltal a fogyaszt\u00f3i \u00e9s a v\u00e1llalati piacra k\u00edn\u00e1lt r\u00e9szlegek. Mindk\u00e9t term\u00e9kcsal\u00e1d el\u0151nye az \u00e1tfog\u00f3, eg\u00e9sz h\u00e1l\u00f3zatra kiterjed\u0151 vizualiz\u00e1ci\u00f3 \u00e9s a k\u00f6zponti, dedik\u00e1lt menedzsment az UniFi CloudKey Controller vagy az UniFi DreamMachine (UDM) seg\u00edts\u00e9g\u00e9vel, k\u00fcl\u00f6n\u00f6sen az UniFi Camera System (UniFi Protect) vagy az UniFi DreamRouter (UDR) rendszerrel egy\u00fctt.<br>Minden Pro vagy Enterprise v\u00e1ltozat t\u00e1mogatja a kiterjesztett Layer 3 funkci\u00f3kat, p\u00e9ld\u00e1ul a VLAN-t.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Olvas\u00e1si id\u0151<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">percek<\/span><\/span>In der Netzwerktechnik nehmen Switches und die Verkabelung zentrale Funktionen ein. Was zu beachtende Unterschiede und Auswahlkriterien betrifft, soll nachfolgend er\u00f6rtert werden. Netzwerk-Kabel Abschirmung Netzwerkkabel sind als 4-paarig verdrillte Einzelkabel mit gemeinsamem Kupfer-Geflecht zur Abschirmung externer St\u00f6rfelder ausgef\u00fchrt (S\/FTP &#8211; Screened Foiled Twisted Pair). Die Verdrillung eliminiert intern auftretende St\u00f6rfelder.Kabel mit einzeln zus\u00e4tzlich mit Geflecht&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/hu\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/\" rel=\"bookmark\">Olvass tov\u00e1bb \"<span class=\"screen-reader-text\">H\u00e1l\u00f3zati technol\u00f3gia - kapcsol\u00f3k \u00e9s k\u00e1belez\u00e9s<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2553],"tags":[],"class_list":["post-11143","post","type-post","status-publish","format-standard","hentry","category-netzwerk-technik"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/posts\/11143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/comments?post=11143"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/posts\/11143\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/media?parent=11143"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/categories?post=11143"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/tags?post=11143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}