{"id":4026,"date":"2023-04-13T09:01:13","date_gmt":"2023-04-13T09:01:13","guid":{"rendered":"https:\/\/csiag.eu\/?p=4026"},"modified":"2023-04-18T09:31:39","modified_gmt":"2023-04-18T09:31:39","slug":"victron-gx-tank-140","status":"publish","type":"post","link":"https:\/\/csiag.eu\/hu\/blog\/2023\/04\/13\/victron-gx-tank-140\/","title":{"rendered":"Victron GX 140-es tart\u00e1ly"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Tartalomjegyz\u00e9k<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/hu\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Sensor-Ausgang_CBE\" >\u00c9rz\u00e9kel\u0151 kimenet (CBE)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/hu\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Sensor-Eingang_GX_Tank_140\" >\u00c9rz\u00e9kel\u0151 bemenet (GX Tank 140)<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/hu\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Verkabelung\" >K\u00e1belez\u00e9s<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/hu\/blog\/2023\/04\/13\/victron-gx-tank-140\/#Konfiguration\" >Konfigur\u00e1ci\u00f3<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Olvas\u00e1si id\u0151<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">percek<\/span><\/span>\n<p class=\"wp-block-paragraph\">A Victron GX Tank 140 lehet\u0151v\u00e9 teszi ak\u00e1r n\u00e9gy, \u00e1ram- vagy fesz\u00fclts\u00e9gvez\u00e9relt m\u00e9r\u0151kimenettel rendelkez\u0151 tart\u00e1ly\u00e9rz\u00e9kel\u0151, valamint a CBE fesz\u00fclts\u00e9gvez\u00e9relt \u00e9rz\u00e9kel\u0151inek csatlakoztat\u00e1s\u00e1t, amelyeket nagyon gyakran telep\u00edtenek lak\u00f3aut\u00f3kba.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sensor-Ausgang_CBE\"><\/span>\u00c9rz\u00e9kel\u0151 kimenet (CBE)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>barna (GND -)<\/li>\n\n\n\n<li>feh\u00e9r (V +)<\/li>\n\n\n\n<li>z\u00f6ld (jel V out +)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sensor-Eingang_GX_Tank_140\"><\/span>\u00c9rz\u00e9kel\u0151 bemenet (GX Tank 140)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 - feh\u00e9r (V out +)<\/li>\n\n\n\n<li>2 - z\u00f6ld (jel IN +)<\/li>\n\n\n\n<li>3 - barna (GND -)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verkabelung\"><\/span>K\u00e1belez\u00e9s<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Az \u00e9rz\u00e9kel\u0151 csatlakoztat\u00e1sa a GX Tank 140 megfelel\u0151 csatlakoz\u00f3blokkj\u00e1hoz <a href=\"https:\/\/www.amazon.de\/dp\/B0BGY8D4WP?psc=1&amp;ref=ppx_yo2ov_dt_b_product_details\" target=\"_blank\" rel=\"noreferrer noopener\">Vez\u00e9rl\u0151vonal<\/a> LiYCY \u00e1rny\u00e9kolt 4 x 0.25 mm<sup>2<\/sup> aj\u00e1nlott. Ha lehets\u00e9ges, a k\u00e1bel \u00fatvonal\u00e1t a megl\u00e9v\u0151 k\u00e1belekkel p\u00e1rhuzamos t\u00e1vols\u00e1gban kell kiv\u00e1lasztani.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Felh\u00edvjuk a figyelmet arra, hogy az \u00e9rz\u00e9kel\u0151k k\u00fcls\u0151, bal oldali k\u00e9tp\u00f3lus\u00fa csatlakoz\u00f3blokkj\u00e1hoz az I. \u00e9s II. csatlakoz\u00f3blokkokn\u00e1l l\u00e9v\u0151 \u00e9rz\u00e9kel\u0151k k\u00fcls\u0151, a haszn\u00e1lt \u00e9rz\u00e9kel\u0151kh\u00f6z anal\u00f3g t\u00e1pell\u00e1t\u00e1s\u00e1t kell csatlakoztatni (pl. 5 V vagy 12 V DC).<br>A II. \u00e9s IV. termin\u00e1lblokkok viszont bels\u0151leg 24 V DC-vel vannak ell\u00e1tva.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A csatlakoztat\u00e1s 1:1 ar\u00e1nyban t\u00f6rt\u00e9nik, azaz a GX Tank 140 I. csatlakoz\u00f3blokkj\u00e1n az 1. csatlakoz\u00f3 balr\u00f3l az els\u0151 a feh\u00e9r k\u00e1bellel, a k\u00f6z\u00e9ps\u0151 a z\u00f6lddel, a jobb oldali pedig a barn\u00e1val. Ugyanez a csatlakoztat\u00e1si sorrend \u00e9rv\u00e9nyes a II. blokkokra ... IV, felt\u00e9ve, hogy azonos \u00e9rz\u00e9kel\u0151k vannak csatlakoztatva.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Konfiguration\"><\/span>Konfigur\u00e1ci\u00f3<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Amint a Victron GX Tank 140 csatlakoztatva lett a Victron Cerbo GX-hez az \u00e1lland\u00f3an telep\u00edtett USB-k\u00e1belen kereszt\u00fcl, a konfigur\u00e1ci\u00f3 a Victron Cerbo GX Touch Panel alatt v\u00e9gezhet\u0151 el. <code>Be\u00e1ll\u00edt\u00e1sok<\/code> \u00e9s az \u00faj eszk\u00f6zbejegyz\u00e9sek.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6.png\" alt=\"\" class=\"wp-image-4072\" width=\"407\" height=\"233\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6.png 976w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6-300x172.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-6-768x441.png 768w\" sizes=\"(max-width: 407px) 100vw, 407px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Ha a bejegyz\u00e9s <code>Csatlakoztatva<\/code> a  c\u00edmen <code>Igen<\/code> megtal\u00e1lhat\u00f3 a <code>N\u00e9v<\/code> az \u00e9rz\u00e9kel\u0151t egyedi n\u00e9vvel lehet megjel\u00f6lni. A bal fels\u0151 sarokban l\u00e9v\u0151 ny\u00edlra kattintva egy szintet l\u00e9phet vissza.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8.png\" alt=\"\" class=\"wp-image-4074\" width=\"406\" height=\"232\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8.png 976w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8-300x172.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-8-768x439.png 768w\" sizes=\"(max-width: 406px) 100vw, 406px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">A men\u00fcpont alatt <code>Be\u00e1ll\u00edt\u00e1s<\/code> a t\u00f6bbi be\u00e1ll\u00edt\u00e1s elv\u00e9gezhet\u0151:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-9.png\" alt=\"\" class=\"wp-image-4075\" width=\"408\" height=\"379\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-9.png 540w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-9-300x279.png 300w\" sizes=\"(max-width: 408px) 100vw, 408px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">A t\u00e9tel <code>\u00c9rz\u00e9kel\u0151 \u00e9rt\u00e9k<\/code>. Ha a tart\u00e1ly r\u00e9szben tele van, itt egy fesz\u00fclts\u00e9g\u00e9rt\u00e9ket kell megjelen\u00edteni. Ha 0,0 V jelenik meg, akkor vagy az \u00e9rz\u00e9kel\u0151 csatlakoz\u00e1sa, vagy az 5 V-os t\u00e1pegys\u00e9g nincs jelen.<br>\u00dagy t\u0171nik, hogy a k\u00e9tp\u00f3lus\u00fa 5 V-os csatlakoz\u00f3blokk id\u0151r\u0151l id\u0151re \u00e9rintkez\u00e9si probl\u00e9m\u00e1kat okoz. Ennek ellen\u0151rz\u00e9s\u00e9re a csatlakoz\u00f3blokkhoz csatlakoztatott k\u00e1belt a t\u00e1pegys\u00e9ghez val\u00f3 csatlakoztat\u00e1s el\u0151tt ellen\u0151rizni kell a folytonoss\u00e1got.<br>A pozit\u00edv csatlakoz\u00e1s ellen\u00e1ll\u00e1sa a V<sub>out<\/sub>-kapcsolatok. A m\u00ednusz vezet\u00e9knek folytonoss\u00e1ga van az \u00f6sszes t\u00f6bbi GND-csatlakoz\u00e1son. Ha itt megszakad\u00e1st \u00e9szlel\u00fcnk, a megfelel\u0151 k\u00e1belt ki kell venni a csatlakoz\u00f3blokkb\u00f3l, sz\u00fcks\u00e9g eset\u00e9n hosszabbra kell cs\u00edkozni \u00e9s \u00fajra be kell dugni, vagy egy nagyobb, 0,5 ... 0,75 mm-es<sup>2<\/sup> haszn\u00e1lni.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Az al\u00e1bbiakat mindig meg kell sz\u00fcntetni <code>Tart\u00e1ly kapacit\u00e1sa<\/code> \u00e9s a <code>T\u00f6lt\u0151k\u00f6zeg<\/code>\u00e9s a fesz\u00fclts\u00e9g \u00e9rt\u00e9ke, amikor a tart\u00e1ly tele van (\u00e1ltal\u00e1ban megfelel az \u00e9rz\u00e9kel\u0151 t\u00e1pfesz\u00fclts\u00e9g\u00e9nek).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A kit\u00f6lt\u00e9si szintek ezut\u00e1n a k\u00f6vetkez\u0151k\u00e9ppen jelennek meg az \u00e1ltal\u00e1nos \u00e1ttekint\u00e9sben:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/04\/image-10.png\" alt=\"\" class=\"wp-image-4076\" width=\"122\" height=\"83\"\/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Olvas\u00e1si id\u0151<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">percek<\/span><\/span>A Victron GX Tank 140 lehet\u0151v\u00e9 teszi ak\u00e1r n\u00e9gy, \u00e1ram- vagy fesz\u00fclts\u00e9gvez\u00e9relt m\u00e9r\u0151kimenettel rendelkez\u0151 tart\u00e1ly\u00e9rz\u00e9kel\u0151, valamint a CBE fesz\u00fclts\u00e9gvez\u00e9relt \u00e9rz\u00e9kel\u0151inek csatlakoztat\u00e1s\u00e1t, amelyeket nagyon gyakran telep\u00edtenek lak\u00f3aut\u00f3kba. \u00c9rz\u00e9kel\u0151 kimenet (CBE) \u00c9rz\u00e9kel\u0151 bemenet (GX Tank 140) Bek\u00f6t\u00e9s Az \u00e9rz\u00e9kel\u0151t a GX Tank 140 megfelel\u0151 csatlakoz\u00f3blokkj\u00e1hoz \u00e1rny\u00e9kolt LiYCY vez\u00e9rl\u0151k\u00e1bellel kell csatlakoztatni.&nbsp;<a href=\"https:\/\/csiag.eu\/hu\/blog\/2023\/04\/13\/victron-gx-tank-140\/\" rel=\"bookmark\">Olvass tov\u00e1bb \"<span class=\"screen-reader-text\">Victron GX 140-es tart\u00e1ly<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4026","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/posts\/4026","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/comments?post=4026"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/posts\/4026\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/media?parent=4026"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/categories?post=4026"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/hu\/wp-json\/wp\/v2\/tags?post=4026"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}