{"id":4492,"date":"2023-06-01T18:27:13","date_gmt":"2023-06-01T18:27:13","guid":{"rendered":"https:\/\/csiag.eu\/?p=4492"},"modified":"2024-10-28T09:44:39","modified_gmt":"2024-10-28T09:44:39","slug":"installazione-di-sistema-uv-c-ad-osmosi-inversa","status":"publish","type":"post","link":"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/","title":{"rendered":"Installazione di impianto ad osmosi inversa e UV-C"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_90 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sommario<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Wohin_mit_den_Anlagen\" >Dove dovrebbero andare i sistemi?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Vorbereitung_des_Serviceklappen-Einbaus\" >Predisposizione per l&#039;installazione dello sportello di servizio<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Service-Klappen_Einbau_%E2%80%93_Vorbereitungen\" >Installazione dello sportello di servizio \u2013 preparativi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Anfertigen_des_Ausschnitts\" >Realizzare il ritaglio<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Entfernen_der_Innenwand\" >Rimozione del muro interno<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Ausschnitt_des_Serviceklappen-Einsatzes\" >Particolare dell&#039;inserto della patta di servizio<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Einbau_der_Osmose-_und_UV-C-Anlage\" >Installazione dell&#039;impianto ad osmosi e UV-C<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Verrohrung\" >Tubazioni<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Drei-Wege-Ventil\" >Valvola a tre vie<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Elektro-Anschluss\" >Collegamento elettrico<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Fazit\" >Conclusione<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/#Einwande\" >Obiezioni?<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Momento della lettura<\/span> <span class=\"rt-time\"> 10<\/span> <span class=\"rt-label rt-postfix\">minuti<\/span><\/span>\n<p class=\"wp-block-paragraph\">La funzione del <a href=\"https:\/\/csiag.eu\/it\/osmosi-inversa\/\" data-type=\"post\" data-id=\"2131\" target=\"_blank\" rel=\"noreferrer noopener\">Osmosi inversa<\/a> E <a href=\"https:\/\/csiag.eu\/it\/disinfezione-dellacqua-uv-c\/\" data-type=\"post\" data-id=\"1912\" target=\"_blank\" rel=\"noreferrer noopener\">Sistema UV-C<\/a> \u00e8 gi\u00e0 stato descritto. Qui verr\u00e0 descritta l&#039;installazione nel nostro camper Flair 7100 del 2005. Vengono discusse le particolarit\u00e0 di questa versione del veicolo, dove si trova la posizione di installazione ottimale e quali insidie devono essere prese in considerazione.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wohin_mit_den_Anlagen\"><\/span>Dove dovrebbero andare i sistemi?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Gli evidenti spazi aperti sono solitamente gi\u00e0 occupati da ogni sorta di cose e sono quindi in gran parte fuori discussione. Esistono per\u00f2 anche dei volumi nascosti che sono predestinati a questo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nel mobile della cucina dietro il lavello si trovano due sportelli sotto i quali si trovano gli inserti per i contenitori dei rifiuti. Sotto c&#039;\u00e8 spazio morto, cio\u00e8 dietro i cassetti e il mobile base.<br>Ci\u00f2 \u00e8 limitato da due pannelli di legno, che da un lato formano l&#039;estremit\u00e0 posteriore della cassettiera e dall&#039;altro separano il radiatore e i tubi dell&#039;acqua, compresa la tubazione delle acque reflue.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una patta esterna con dimensioni esterne di 39,5 x 70,0 cm (<a href=\"https:\/\/www.obelink.de\/thetford-grosse-4-serviceklappe.html\" target=\"_blank\" rel=\"noreferrer noopener\">Sportello di servizio Thetford misura 4<\/a>) lascia spazio sufficiente per l&#039;installazione, il funzionamento e la manutenzione sia del sistema di osmosi che del chiarificatore UV-C, compresa la tecnologia e il convertitore DCDC (<a href=\"https:\/\/www.victronenergy.de\/upload\/documents\/Datasheet-Orion-Tr-DC-DC-converters-isolated-100-250-400W-DE.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Victron Orion 12\/24 10 A<\/a>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inoltre, la tubazione delle acque reflue \u00e8 direttamente disponibile per il controlavaggio delle acque reflue dell&#039;impianto ad osmosi, cos\u00ec come il tubo dell&#039;acqua fredda per l&#039;alimentazione dell&#039;acqua dolce nell&#039;impianto ad osmosi e l&#039;acqua dell&#039;osmosi nel tubo di alimentazione dell&#039;acqua fredda del rubinetto standard (!) .<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Resta da posare solo la linea di alimentazione a 12 V DC.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Vorbereitung_des_Serviceklappen-Einbaus\"><\/span>Predisposizione per l&#039;installazione dello sportello di servizio<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 dietro l&#039;apertura prevista non si pu\u00f2 vedere dall&#039;esterno i cavi ecc., dall&#039;interno deve essere praticato un foro di contrassegno corrispondente. Ci\u00f2 richiede un trapano lungo (almeno 200 mm) da 5 mm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per prima cosa occorre togliere dagli sportelli i due contenitori dietro al lavello. All&#039;incirca al centro si vede un taglio rettangolare pulito nella parete di legno posteriore attraverso il quale passano i tubi di alimentazione dell&#039;acqua e delle acque reflue. A met\u00e0 altezza del limite destro del ritaglio, viene praticato il foro di marcatura a una distanza di 2 cm da esso (assicurarsi che la punta sia orizzontale) finch\u00e9 la punta non fuoriesce dalla pelle esterna. Questo segna l&#039;estremit\u00e0 sinistra dell&#039;orizzontale all&#039;esterno prima dell&#039;inizio dell&#039;angolo arrotondato in alto a sinistra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ora traccia una linea orizzontale a 85 mm dal bordo inferiore del ritaglio dalla parete sinistra a destra utilizzando una striscia di legno lunga circa 50 cm e un pennarello indelebile spesso. Lungo questa linea \u00e8 con a <a href=\"https:\/\/www.makita.de\/akku-multifunktionswerkzeug-dtm52.html\" target=\"_blank\" rel=\"noreferrer noopener\">Dispositivo multifunzionale<\/a> e una lama per sega segmentata a 270\u00b0 separavano il pannello posteriore. Poco prima di raggiungere la parete laterale il taglio con la lama a segmenti viene interrotto e la stessa viene sostituita con una lama diritta. Questo viene posizionato ad angolo retto per tagliare con attenzione le sezioni mancanti fino alla rispettiva parete laterale. Gli ultimi 15 mm richiedono un po&#039; pi\u00f9 tempo perch\u00e9 dietro la tavola c&#039;\u00e8 una striscia di legno.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Service-Klappen_Einbau_%E2%80%93_Vorbereitungen\"><\/span>Installazione dello sportello di servizio \u2013 preparativi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le dime di taglio sono incluse con le alette di servizio. Innanzitutto vengono ritagliate le dimensioni esterne dello sportello di servizio completo lungo la linea \u201cA\u201d. Questo NON serve per ritagliare l&#039;apertura della parete laterale, ma semplicemente per verificare l&#039;eventuale posizione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La linea \u201cC\u201d rappresenta il ritaglio per l&#039;installazione dello sportello di servizio, \u201cB\u201d il ritaglio per l&#039;inserto della porta, che \u00e8 ricavato dal ritaglio \u201cC\u201d.<br>Innanzitutto ritagliare lungo la linea \u201cC\u201d e trasferire i bordi sul muro esterno con un pennarello indelebile nella posizione determinata al centro dell&#039;area determinata \u201cA\u201d. Si prega di notare la posizione del foro di marcatura come guida!<br>In questo caso non \u00e8 possibile seguire la procedura suggerita nelle istruzioni con i due fori di posizionamento, in quanto non \u00e8 possibile il trasferimento e la marcatura sulla parete interna.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Anfertigen_des_Ausschnitts\"><\/span>Realizzare il ritaglio<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dopo aver controllato nuovamente la posizione, \u00e8 possibile tracciare la marcatura e tagliare la parete con l&#039;utensile multifunzione e la lama segmentata montata.<br>Lo spessore della parete \u00e8 tuttavia maggiore della profondit\u00e0 utile della lama a segmenti. Pertanto il lavoro successivo dovr\u00e0 essere eseguito con una lama diritta per raggiungere e tagliare lo strato posteriore di alluminio e legno.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Solo (!) gli angoli vengono tagliati molto lentamente e con attenzione con una lama per sega per metallo a dentatura fine profonda max. 55 mm e un seghetto alternativo. Assicurarsi che vi sia un contatto costante tra la base del seghetto alternativo e la pelle esterna. Il piede deve essere coperto con nastro adesivo per evitare graffi sulla vernice. Per una protezione aggiuntiva, \u00e8 anche possibile attaccare del nastro adesivo alla vernice lungo i bordi tagliati.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lo spessore della parete del Flair 7100 \u00e8 di 50 mm, pi\u00f9 lo strato di moquette all'interno. Per questo motivo, in genere lo strato di moquette non viene raggiunto completamente dal seghetto alternativo e deve essere tagliato manualmente con una lama lunga per moquette. Gli angoli arrotondati possono essere rielaborati con un coltello da taglio, poich\u00e9 \u00e8 pi\u00f9 stretto e quindi in grado di seguire le curve strette.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al confine, intorno al quinto inferiore del bordo verticale destro, incontrerete una resistenza: il tubo del riscaldamento. \u00c8 profondo circa 55 mm dalla pelle esterna e verrebbe sicuramente danneggiato se venisse utilizzata una lama per seghetto alternativo pi\u00f9 lunga!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se il tappeto posteriore \u00e8 stato completamente tagliato, il lato sinistro dovrebbe ora poter essere spinto verso l&#039;interno o (usando un righello attraverso la rientranza rettangolare nella parete divisoria in legno posteriore) dall&#039;interno verso l&#039;esterno. Altrimenti dovr\u00e0 essere rielaborato di nuovo. Potrebbe esserci un supporto per fascetta in plastica qui che tiene in posizione uno dei due tubi dell&#039;acqua dolce e deve essere tagliato con una lama per sega metallica da un seghetto (possibilmente anche la vite di fissaggio).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sul lato destro il tubo del riscaldamento \u00e8 fissato con una fascetta stringitubo, motivo per cui qui non \u00e8 possibile cedere. Pertanto \u00e8 necessario creare spazio sufficiente tra la parete esterna e l&#039;apertura in modo da poter allentare la vite a croce sulla fascetta stringitubo utilizzando il braccio e un piccolo cricchetto con inserto a croce di medie dimensioni. Ora puoi spostare anche il lato destro e rimuovere cos\u00ec completamente la sezione.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Entfernen_der_Innenwand\"><\/span>Rimozione del muro interno<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le viti a croce del listello destro della parete posteriore interna, segato dall&#039;interno, sono ora accessibili dall&#039;esterno. Questi vengono rimossi con un cacciavite Phillips medio. Una volta che la striscia \u00e8 stata tagliata in modo netto, \u00e8 possibile spingere leggermente verso l&#039;interno la parete posteriore a destra.<br>In questo modo \u00e8 possibile accedere anche alle viti di sinistra, che possono anche essere rimosse. Ora la tavola \u00e8 allentata, ma ancora troppo grande per passare attraverso l&#039;apertura creata all&#039;esterno. Pertanto, nella continuazione della rientranza inferiore sinistra, si sega la parte destra disturbante con l&#039;utensile multifunzione e si rimuove il pannello.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prima di installare e collegare i sistemi ad osmosi e UV-C \u00e8 necessario astenersi dall&#039;installare lo sportello di servizio e mascherare temporaneamente l&#039;apertura se l&#039;operazione deve essere eseguita all&#039;aperto e non pu\u00f2 essere completata in un giorno.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ausschnitt_des_Serviceklappen-Einsatzes\"><\/span>Particolare dell&#039;inserto della patta di servizio<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per realizzare l&#039;inserto a ribalta, si posiziona la dima ritagliata lungo la linea \u201cB\u201d al centro del ritaglio nel muro e si tracciano i bordi con un pennarello indelebile. Se necessario, prestare attenzione agli adesivi con motivi. Utilizzando il seghetto alternativo e una lama lunga (!) per metallo (lunghezza minima con il seghetto alternativo retratto &gt; 60 mm), realizzare il ritaglio seguendo la marcatura.<br>Le lame della sega pi\u00f9 corte causano il distacco della parte posteriore in alluminio\/legno a causa del taglio incompleto!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il ritaglio viene inserito nel telaio della porta come prova. Se ci sono aree che necessitano di essere rifinite, \u00e8 possibile farlo rapidamente con una raspa fine. Non appena si ottiene l&#039;adattamento, la scanalatura nel telaio viene riempita generosamente e senza interruzioni con l&#039;adesivo per il corpo, il ritaglio viene inserito e premuto saldamente. L&#039;eventuale adesivo che fuoriesce da dietro deve essere rimosso immediatamente senza lasciare residui. La colla viene aggiunta anche al bordo del telaio interno e ai montanti (per dimensioni delle alette maggiori) e anche il telaio viene pressato con precisione. Prima dell&#039;ulteriore lavorazione prestare attenzione al tempo di indurimento dell&#039;adesivo!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Einbau_der_Osmose-_und_UV-C-Anlage\"><\/span>Installazione dell&#039;impianto ad osmosi e UV-C<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il convertitore DCDC (da 12 V a 24 V) per l'impianto di osmosi e l'unit\u00e0 di controllo per il chiarificatore UV-C possono ora essere installati. Si trovano sulla parete sinistra del mobile della cucina e sono ancora accessibili, ma non interferiscono con il cambio occasionale del filtro dell'impianto di osmosi o della lampada del chiarificatore UV-C da 254 nm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il coperchio della centralina PURION UV-C pu\u00f2 essere ruotato in modo da poter essere svitato con gli elementi di comando rivolti verso il basso per facilitare l'accesso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alla sua destra \u00e8 posizionato l&#039;impianto ad osmosi e davanti ad esso il chiarificatore UVC \u00e8 fissato a due viti prigioniere con due morsetti per proteggerlo dalle vibrazioni.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"524\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose-UVC.jpg\" alt=\"\" class=\"wp-image-4557\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose-UVC.jpg 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose-UVC-300x197.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose-UVC-768x503.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Il pannello di controllo dell&#039;impianto ad osmosi \u00e8 stato rimosso dal telaio e montato sopra l&#039;armadio della cucina. Ci\u00f2 significa che puoi sempre tenere d&#039;occhio lo stato del sistema.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"382\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Controller.png\" alt=\"\" class=\"wp-image-7897\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Controller.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Controller-18x9.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Controller-300x143.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Controller-768x367.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Centralina \/ unit\u00e0 di controllo del sistema di osmosi<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 l&#039;apparecchio \u00e8 collegato ai componenti collegati tramite un collegamento a innesto, \u00e8 necessario tagliare questo e utilizzare un connettore da 10 x 0,5 mm<sup>2<\/sup> Linea di controllo da ricollegare \u2013 estesa. I fili della linea di controllo sono numerati da 1 a 9, la decima linea \u00e8 codificata a colori verde e giallo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L&#039;assegnazione dei cavi \u00e8 quindi la seguente (da sinistra a destra):<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"480\" height=\"289\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Stecker.jpg\" alt=\"\" class=\"wp-image-4560\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Stecker.jpg 480w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_Stecker-300x181.jpg 300w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">I numeri romani indicano il primo o il secondo dei codici colore duplicati. Per differenziarlo, si consiglia di effettuare opportune marcature sul cavo con un pennarello indelebile (un punto \/ due punti, due volte per cavo ad una distanza di circa 5 cm. Le marcature vengono tagliate al centro delle marcature. Dopo la spelatura e la crimpatura i puntalini dei fili, le marcature sono ancora visibili e viene quindi fornita un&#039;assegnazione corretta.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 \u2013 giallo I \u2013 valvola di commutazione elettromagnetica (acqua di processo\/risciacquo)<\/li>\n\n\n\n<li>2 \u2013 blu I \u2013 pressostato&nbsp;<\/li>\n\n\n\n<li>3 \u2013 blu II \u2013 pressostato&nbsp;<\/li>\n\n\n\n<li>4 \u2013 rosso I \u2013 elettrovalvola \u2013 scarico acque OUT<\/li>\n\n\n\n<li>5 \u2013 verde I \u2013 24 V \u2013 PLUS (pompa) \/ \/ nero I (valvola elettromagnetica \u2013 INGRESSO acque nere)<\/li>\n\n\n\n<li>6 \u2013 giallo II \u2013 valvola di commutazione elettromagnetica (acqua di processo\/risciacquo)<\/li>\n\n\n\n<li>7 \u2013 verde II \u2013 MENO (pompa) \/ \/ nero II (valvola elettromagnetica \u2013 INGRESSO acque reflue)<\/li>\n\n\n\n<li>8 \u2013 rosso II \u2013 elettrovalvola \u2013 scarico acque OUT<\/li>\n\n\n\n<li>9 \u2013 bianco \u2013 MINUS (nero \u2013 alimentatore\/convertitore DCDC)<\/li>\n\n\n\n<li>10 \u2013 rosa \u2013 24 V \u2013 PLUS (rosso \u2013 alimentatore \/ convertitore DCDC)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verrohrung\"><\/span>Tubazioni<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ora si pone la domanda: l'unit\u00e0 UV-C viene prima o dopo l'impianto di osmosi?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alcuni produttori di sistemi di osmosi parlano di una \"barriera germinale\" incorporata. La membrana di osmosi funge da barriera contro i germi, in quanto trattiene tutti i batteri e i virus con una dimensione dei pori di appena 0,00001 \u00b5m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se l'impianto non viene utilizzato in modo continuativo, come nel caso dei camper utilizzati esclusivamente per le vacanze, i germi che risiedono nella membrana dell'osmosi possono moltiplicarsi nel tempo. Ecco la risposta alla domanda posta all'inizio: i raggi UV-C vengono utilizzati PRIMA dell'impianto di osmosi. In questo modo si uccidono i germi a monte dell'impianto e i filtri rimangono privi di germi, anche se l'acqua rimane nell'impianto per un periodo di tempo pi\u00f9 lungo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 opportuno collegare delle valvole a sfera alle rispettive linee di alimentazione, ad esempio per evitare allagamenti durante la sostituzione del filtro (non ancora installato nella foto).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un raccordo a T con valvola a sfera montato sul raccordo in uscita consente di scaricare l'acqua pressurizzata all'esterno tramite un tubo flessibile diretto all'esterno del veicolo.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_UVC_Verrohrung.png\" alt=\"\" class=\"wp-image-7892\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_UVC_Verrohrung.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_UVC_Verrohrung-9x12.png 9w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/06\/Osmose_UVC_Verrohrung-225x300.png 225w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><figcaption class=\"wp-element-caption\">A destra, l'uscita UV-C collegata all'ingresso dell'impianto di osmosi<br>Uscita UV-C sinistra sulla diramazione verso l'attacco del rubinetto della valvola a 3 vie<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Una nota sul collegamento a vite della membrana osmotica (spessa): a seconda del modello, il tappo a vite destro \u00e8 dotato di un O-ring di tenuta che \u00e8 fissato saldamente in una scanalatura per evitare che scivoli o che si innesta pi\u00f9 o meno debolmente in tale scanalatura e tende quindi a scivolare fuori da essa durante la chiusura e quindi non fa tenuta.<br>In quest'ultima versione, \u00e8 utile posizionare il sistema sul lato sinistro: ci\u00f2 consente di posizionare la guarnizione nella scanalatura e di svitare con cautela il coperchio fino a quando non si percepisce che l'O-ring fa buona tenuta.<br>Una prova di funzionamento in questa posizione dovrebbe testimoniare la tenuta ...<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gli altri filtri sono dotati di connessioni a vite autosigillanti, come i quattro filtri installati verticalmente e accessibili dal davanti (da destra a sinistra - filtro PP 10 \u00b5m, filtro GAC a carboni attivi, filtro CTO a carboni attivi 5 \u00b5m, filtro UF 0,02 \u00b5m), o di connessioni dirette con tubi flessibili, come i filtri situati orizzontalmente davanti alla membrana osmotica (T33 - post-trattamento a carboni attivi e la cartuccia gialla sopra di essa, lo stadio di remineralizzazione).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La rimineralizzazione \u00e8 talvolta oggetto di dibattiti controversi. Il sistema osmotico filtra anche i minerali. Tuttavia, questi sono necessari all'organismo. \u00c8 quindi teoricamente logico aggiungerli nuovamente. Tuttavia, l'organismo umano pu\u00f2 utilizzare solo sostanze organiche, ma non inorganiche, ad esempio attraverso alimenti crudi, anche se - nel frattempo - non ne sono abbastanza ricchi. Gli integratori alimentari (NEM) non sono in piena espansione e in questo caso hanno certamente senso come integrazione basata sul fabbisogno. Di conseguenza, la rimineralizzazione non \u00e8 necessaria.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Attenzione: La pompa di alimentazione deve avere una portata sufficiente; se necessario, sostituirla con una pi\u00f9 potente!<\/strong><br><strong>Se per motivi di spazio non \u00e8 possibile installare una pompa pi\u00f9 potente <a href=\"https:\/\/csiag.eu\/it\/invece-di-un-impianto-a-osmosi-in-camper\/\" data-type=\"post\" data-id=\"7986\">Qui<\/a> ha descritto un'alternativa.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Drei-Wege-Ventil\"><\/span>Valvola a tre vie<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La valvola a 3 vie ad azionamento elettrico (a scelta 12 V \/ 24 V CC o 230 V CA) serve a commutare il flusso dell'acqua fredda, attraverso il sistema UV-C\/osmosi o dal serbatoio dell'acqua direttamente al rubinetto ed \u00e8 realizzata tramite un pulsante di inversione dei poli con posizione neutra. Premendo il pulsante in una direzione o nell'altra, l'acqua pu\u00f2 essere pompata attraverso il sistema o direttamente dal serbatoio, a seconda delle necessit\u00e0. Il pulsante inverte elettricamente le due connessioni del motore della valvola a 3 vie e quindi cambia il senso di rotazione del motore, consentendo l'una o l'altra uscita della valvola.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Elektro-Anschluss\"><\/span>Collegamento elettrico<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Anche l'impianto di osmosi, che di solito in casa \u00e8 alimentato in modo permanente a 230 V e quindi rimane sempre acceso, dovrebbe essere collegato manualmente tramite un interruttore facilmente accessibile. In un camper, non \u00e8 consigliabile tenere una pompa a pressione costantemente in standby e mantenere la pressione dell'acqua: altrimenti, in caso di perdita, l'area di installazione si troverebbe rapidamente sott'acqua.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il motore della pompa della maggior parte dei sistemi \u00e8 alimentato a 24 V CC tramite un alimentatore a 230 V CA. Utilizzando un convertitore DCDC da 12 V a 24 V, come indicato sopra, \u00e8 possibile far funzionare il sistema direttamente tramite l'alimentazione di bordo a 12 V CC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I sistemi UV-C sono disponibili con diverse tensioni di funzionamento (12 V \/ 24 V CC o 230 V CA). In questo caso \u00e8 stata scelta la versione a 12 V. L'accensione del sistema avviene tramite un interruttore a levetta verde illuminato sull'unit\u00e0 di controllo (che contiene il ballast e il monitoraggio del tempo di funzionamento della lampada UV-C). Poich\u00e9 in genere non si vuole avere in vista una scatola tecnologica relativamente grande nel camper, lo spazio a sinistra dell'impianto UV-C e di osmosi \u00e8 ideale, come mostrato nella foto qui sopra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lo svantaggio \u00e8 che non \u00e8 possibile vedere i LED di stato del sistema UV-C e l'interruttore \u00e8 inaccessibile dall'interno.<br>Tuttavia, \u00e8 relativamente facile cambiare questa situazione: l'interruttore pu\u00f2 essere indirizzato all'interno dell'area della cucina tramite due cavi collegati in parallelo ai due cavi rossi esistenti, che terminano in un interruttore aggiuntivo, oppure commutato tramite Smarthome.<br>Poich\u00e9 i LED sono saldati alla scheda di controllo con lunghi fili di collegamento, possono essere tagliati e allungati nel campo visivo desiderato con dei cavi. In questo modo \u00e8 possibile controllare nuovamente gli stati di funzionamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Fazit\"><\/span>Conclusione<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'intera catena di filtri attraverso cui passa l'acqua di rubinetto disponibile \u00e8 costituita dal prefiltro a tre stadi, da 25 \u00b5m, 10 \u00b5m e 1 \u00b5m, seguito dal sistema UV-C e dai filtri dell'impianto di osmosi da 10 \u00b5m, 5 \u00b5m e 0,02 \u00b5m, nonch\u00e9 dalla membrana di osmosi da 0,00001 \u00b5m.<br>Al posto dei filtri da 10 \u00b5m e 5 \u00b5m, che ora sono di fatto duplicati, si potrebbero utilizzare anche filtri da 0,5 \u00b5m e 0,1 \u00b5m. Pi\u00f9 fine \u00e8 la (pre)filtrazione, pi\u00f9 lunga \u00e8 la durata della membrana osmotica!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se si utilizza acqua di origine indefinita (lago, stagno, pozzo, ecc.), la catena di filtraggio, oltre ai pre-filtri mobili aggiuntivi quali <a href=\"https:\/\/csiag.eu\/it\/come-entra-lacqua-nel-serbatoio\/\" data-type=\"post\" data-id=\"7689\" target=\"_blank\" rel=\"noreferrer noopener\">Qui<\/a> descritto in modo pi\u00f9 dettagliato, identico.<br>\u00c8 costituito da un cestello filtrante con maglia in acciaio inox da 300 \u00b5m, un filtro a sedimenti in poliestere da 150 mm e un filtro a sedimenti in acciaio inox da 70 \u00b5m, da dove viene pressurizzato da una pompa a membrana e immesso nel sistema di prefiltrazione a tre stadi descritto in precedenza con 25, \u00b5m, 10 \u00b5m e 1 \u00b5m nel serbatoio dell'acqua, da cui viene immesso nel sistema di purificazione UV-C e nel sistema di osmosi a valle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In questo modo, l'acqua - di qualsiasi origine - \u00e8 sempre disponibile assolutamente priva di germi.<\/p>\n\n\n\n<figure class=\"wp-block-pullquote has-text-align-left\"><blockquote><p>Per mantenere la sterilit\u00e0 \u00e8 necessario rispettare gli intervalli di sostituzione dei filtri. A seconda del grado di contaminazione dell'acqua, questi intervalli possono anche essere notevolmente pi\u00f9 brevi di quelli standard previsti dal produttore!<\/p><\/blockquote><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Einwande\"><\/span>Obiezioni?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il lettore attento si sar\u00e0 reso conto che l'acqua filtrata a 1 \u00b5m conterr\u00e0 sicuramente ancora germi. Ci\u00f2 solleva la domanda: l'acqua non sar\u00e0 poi contaminata nel serbatoio dell'acqua?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ec, perch\u00e9 i batteri sono molto pi\u00f9 piccoli di 0,02 ... 0,3 \u00b5m. I filtri che filtrano con dimensioni inferiori a 0,02 \u00b5m, come la membrana di osmosi con 0,00001 \u00b5m, hanno portate molto ridotte e richiedono pressioni di conseguenza pi\u00f9 elevate. Ci\u00f2 comporta tempi di riempimento notevolmente pi\u00f9 lunghi, che possono durare anche diverse ore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tuttavia, la carica batterica che pu\u00f2 derivare da tempi di permanenza pi\u00f9 lunghi dell'acqua nel serbatoio non \u00e8 critica, a condizione che la depurazione UV-C a valle agisca con un'intensit\u00e0 (Joule) sufficiente e quindi non solo assicuri la sterilizzazione, ma impedisca anche la <a href=\"https:\/\/csiag.eu\/it\/disinfezione-dellacqua-uv-c\/\" data-type=\"post\" data-id=\"1912\" target=\"_blank\" rel=\"noreferrer noopener\">Fotolisi<\/a> fornisce. Il sistema a osmosi filtra i germi che sono stati eliminati e fornisce quindi acqua potabile priva di germi e incontaminata sotto ogni aspetto.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">ps Se hai bisogno di supporto personale nell&#039;implementazione a pagamento, sei il benvenuto&nbsp;<a href=\"https:\/\/csiag.eu\/it\/servizio-di-consulenza\/\">biglietteria<\/a>&nbsp;Fare!<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Momento della lettura<\/span> <span class=\"rt-time\"> 10<\/span> <span class=\"rt-label rt-postfix\">minuti<\/span><\/span>Il funzionamento del sistema a osmosi inversa e dei raggi UV-C \u00e8 gi\u00e0 stato descritto. Qui viene descritta l'installazione nel nostro camper, il Flair 7100 costruito nel 2005. Vengono discusse le caratteristiche speciali di questo veicolo, la posizione ottimale per l'installazione e le insidie da tenere in considerazione. Dove collocare i sistemi? Di norma, gli spazi liberi pi\u00f9 ovvi sono gi\u00e0 coperti da...&nbsp;<a href=\"https:\/\/csiag.eu\/it\/blog\/2023\/06\/01\/einbau-umkehr-osmose-uv-c-anlage\/\" rel=\"bookmark\">Leggi tutto \"<span class=\"screen-reader-text\">Installazione di impianto ad osmosi inversa e UV-C<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[317,339,340,338,318],"tags":[632,1714,1712,1715,1716,1366,1710,1711,1713,649,1709],"class_list":["post-4492","post","type-post","status-publish","format-standard","hentry","category-autarkie-im-wohnwagen-wohnmobil","category-umkehr-osmose","category-wasser-entkeimung-mittels-uv-c","category-wasser-management","category-womo-umbau","tag-abwasser","tag-aderendhuelse","tag-bedienteil","tag-druckschalter","tag-elektromagnet-ventil","tag-kabel","tag-osmose-anlagen-rueckspuelung","tag-serviceklappe","tag-steckverbinder","tag-umkehr-osmose-anlage","tag-uv-c-anlage"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/posts\/4492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/comments?post=4492"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/posts\/4492\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/media?parent=4492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/categories?post=4492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/it\/wp-json\/wp\/v2\/tags?post=4492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}