{"id":11640,"date":"2025-11-19T18:47:27","date_gmt":"2025-11-19T18:47:27","guid":{"rendered":"https:\/\/csiag.eu\/?p=11640"},"modified":"2025-12-10T11:50:50","modified_gmt":"2025-12-10T11:50:50","slug":"%e8%b2%af%e6%b0%b4%e6%a7%bd%e3%81%ae%e8%a8%88%e7%94%bb","status":"publish","type":"post","link":"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/","title":{"rendered":"\u98f2\u6599\u6c34\u8caf\u6c34\u69fd\u306e\u8a08\u753b"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inhaltsverzeichnis<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Wasser-Analyse_und_Grenzwerte\" >Wasser-Analyse und Grenzwerte<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Wasserharte\" >Wasserh\u00e4rte<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Wasserenthartung\" >Wasserenth\u00e4rtung<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Impfkristallisations-Technologien\" >Impfkristallisations-Technologien<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#TAC\" >TAC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#NAC\" >NAC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#MAC\" >MAC<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Anbieter_von_Systemen_mit_Impfkristallisation\" >Anbieter von Systemen mit Impfkristallisation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Ergiebigkeit_der_Quelle\" >Ergiebigkeit der Quelle<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Auswahl_der_Forderpumpe\" >Auswahl der F\u00f6rderpumpe<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Ventile\" >Ventile<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/#Fullstands-Messung\" >F\u00fcllstands-Messung<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesedauer<\/span> <span class=\"rt-time\"> 6<\/span> <span class=\"rt-label rt-postfix\">Minuten<\/span><\/span>\n<p class=\"wp-block-paragraph\">Die Planung von Trinkwasser-Zisternen umfasst mehrere physikalische Gegebenheiten, die es zu ber\u00fccksichtigen gilt, will man mit m\u00f6glichst geringem Aufwand die gew\u00fcnschte Trinkwasser-Qualit\u00e4t und F\u00f6rderleistung erzielen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wasser-Analyse_und_Grenzwerte\"><\/span><strong>Wasser-Analyse und Grenzwerte<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Zun\u00e4chst ist von jeder Wasserquelle eine Laboranalyse zu fertigen, mittels derer die Wasserwerte mit den geltenden Grenzwerten verglichen werden, um ggf. gezielt Ma\u00dfnahmen zur Einhaltung derselben ergreifen zu k\u00f6nnen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Acrylamid 0,10 \u03bcg\/l<\/li>\n\n\n\n<li>Antimon 10 \u03bcg\/l<\/li>\n\n\n\n<li>Arsen 10 \u03bcg\/l<\/li>\n\n\n\n<li>Benzol 1,0 \u03bcg\/l<\/li>\n\n\n\n<li>Benzo(a)pyren 0,010 \u03bcg\/l<\/li>\n\n\n\n<li>Bisphenol A 2,5 \u03bcg\/l<\/li>\n\n\n\n<li>Bor 1,5 mg\/l<\/li>\n\n\n\n<li>Bromat 10 \u03bcg\/l<\/li>\n\n\n\n<li>Cadmium 5,0 \u03bcg\/l<\/li>\n\n\n\n<li>Chlorat 0,25 mg\/l<\/li>\n\n\n\n<li>Chlorit 0,25 mg\/l<\/li>\n\n\n\n<li>Chrom 25 \u03bcg\/l<\/li>\n\n\n\n<li>Kupfer 2,0 mg\/l<\/li>\n\n\n\n<li>Cyanid 50 \u03bcg\/l<\/li>\n\n\n\n<li>1,2-Dichlorethan 3,0 \u03bcg\/l<\/li>\n\n\n\n<li>Epichlorhydrin 0,10 \u03bcg\/l<\/li>\n\n\n\n<li>Fluorid 1,5 mg\/l<\/li>\n\n\n\n<li>Halogenessigs\u00e4uren (HAAs) 60 \u03bcg\/l<\/li>\n\n\n\n<li>Blei 5 \u03bcg\/l<\/li>\n\n\n\n<li>Quecksilber 1,0 \u03bcg\/l<\/li>\n\n\n\n<li>Microcystin-LR 1,0 \u03bcg\/l<\/li>\n\n\n\n<li>Nickel 20 \u03bcg\/l<\/li>\n\n\n\n<li>Nitrat 50 mg\/l<\/li>\n\n\n\n<li>Nitrit 0,50 mg\/l<\/li>\n\n\n\n<li>Pestizide 0,10 \u03bcg\/l<\/li>\n\n\n\n<li>Pestizid gesamt 0,50 \u03bcg\/l<\/li>\n\n\n\n<li>PFAS gesamt 0,50 \u03bcg\/l<\/li>\n\n\n\n<li>Summe der PFAS 0,10 \u03bcg\/l<\/li>\n\n\n\n<li>Polyzyklische aromatische Kohlenwasserstoffe 0,10 \u03bcg\/l<\/li>\n\n\n\n<li>Selen 20 \u03bcg\/l<\/li>\n\n\n\n<li>Tetrachlorethen und Trichlorethen 10 \u03bcg\/l<\/li>\n\n\n\n<li>Trihalogenmethane gesamt 100 \u03bcg\/l<\/li>\n\n\n\n<li>Uran 30 \u03bcg\/l<\/li>\n\n\n\n<li>Vinylchlorid 0,50 \u03bcg\/l<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wasserharte\"><\/span><strong>Wasserh\u00e4rte<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Wasserh\u00e4rte repr\u00e4sentiert den Gehalt von Calciumcarbonat (CaCO\u2083) in <strong>mmol\/l<\/strong>, <strong>ppm<\/strong> oder <strong>mg\/l<\/strong>  (1 mmol\/l = 1 ppm\/l = 1 mg\/l) Erdalkali-Ionen gem\u00e4\u00df dem internationalen Einheitssystem SI (<em>Syst\u00e8me International d&#8217;Unit\u00e9s<\/em>), veraltet auch noch in \u00b0dH (deutsche H\u00e4rte 1 \u00b0dH entspricht 0,1783 mml\/l), angegeben.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>weiches Wasser -&gt; kleiner 8,4 \u00b0dH, entsprechend kleiner 1,5 mmoll<\/li>\n\n\n\n<li>mittel -&gt; 8,4 .. 14 \u00b0dH, entsprechend 1,5 .. 2,5 mmol\/l<\/li>\n\n\n\n<li>hartes Wasser -&gt; gr\u00f6\u00dfer 14 \u00b0dH, entsprechend gr\u00f6\u00dfer 2,5 mmol\/l<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Die Wasserh\u00e4rte zeigt sich u.a. in Kalkablagerungen in Leitungen, auf von Wasser benetzten Oberfl\u00e4chen und im Verbrauch von mehr Waschmittel je kalkhaltiger, mithin h\u00e4rter das Wasser ist.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wasserenthartung\"><\/span><strong>Wasserenth\u00e4rtung<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wasserenth\u00e4rtung kann auf zwei Wegen vorgenommen werden, so durch:&nbsp;<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ionentauscher<\/strong> (hier wird Wasser durch einen mit Natrium-Ionen ges\u00e4ttigten Harzfilter geleitet, wobei ein Austausch von im Wasser gel\u00f6sten Calcium- und Magnesium-Ionen gegen die Natrium-Ionen des Harzes stattfindet.<br>Ionentauscher sind je nach Durchflussmenge fr\u00fcher oder sp\u00e4ter mit Calcium- und Magnesium-Ionen ges\u00e4ttigt und m\u00fcssen dann mit einer hochkonzentrierten Kochsalz-L\u00f6sung (NaCl) gesp\u00fclt, regeneriert werden. Danach k\u00f6nnen sie wieder Calcium- und Magnesium-Ionen aufnehmen und entsprechend Natrium-Ionen abgeben.<br>Derlei Anlagen ben\u00f6tigen im Laufe eines Jahres je nach Durchsatz gro\u00dfe Mengen, ein nach <em>EN 973 Typ <\/em>A zertifiziertes, hochreines Salz mit einer Reinheit \u00fcber 99,5 %.<br>Nachteilig ist die Anreicherung des Wassers mit Natrium, womit der Gedanke &#8222;natriumarmen&#8220; Trinkwassers konterkariert wird. Ebenso nat\u00fcrlich die wiederkehrenden Kosten f\u00fcr das Regenerations-Salz, wie den damit verbundenen Wartungsaufwand.<\/li>\n\n\n\n<li><strong>Umkehrosmose<\/strong>, indem das Wasser mit hohem Druck durch 0,00001 \u00b5m feine Filterporen gepresst wird. Nachteilig ist allerdings, dass das resultierende Wasser keinerlei Mineralstoffe mehr enth\u00e4lt und somit re-mineralisiert werden muss, um f\u00fcr den menschlichen Organismus wieder verwertbar zu werden.<br>Nachteilig sind die regelm\u00e4\u00dfig wiederkehrenden Kosten f\u00fcr die Osmosemembran (Filterkartusche) und das &#8222;Wasser&#8220;, das bei der Umkehrosmose anf\u00e4llt und bis zu 50% zus\u00e4tzlichen Wasserverbrauch betragen kann.<\/li>\n\n\n\n<li><strong>Destillation<\/strong>, was ebenfalls in Wasser ohne jeglichen Mineralstoffgehalt m\u00fcndet und damit f\u00fcr den Menschen gesundheitlich kontraproduktiv ist.<br>Nachteilig ist zus\u00e4tzlich der hohe Energieaufwand.<\/li>\n\n\n\n<li><strong>Impfkristallisation<\/strong>, bei der mittels eines Katalysators (gef\u00fcllt mit speziell beschichteten Keramik oder Polymer-K\u00fcgelchen, an denen Calcium- und Carbonat-Ionen andocken und auskristallisieren) der das Kalkablagerungen verursachende Calcit in nadelf\u00f6rmige, nicht mehr anhaftende Aragonit-Kristalle umwandelt.<br>Das Wasser beinhaltet nach wie vor alle Mineralien, inklusive &#8222;Kalk&#8220; in Form der Aragonit-Kristalle).<br>F\u00fcr den Organismus ist dieses Wasser vollst\u00e4ndig nutzbar.<br>Solche Ger\u00e4te haben Standzeiten von \u00fcber zehn Jahren, je nach Durchsatz und Dimensionierung. Sie werden in die Hauptzuleitung der Hauswasserversorgung nach dem Wasserz\u00e4hler eingeschleift.<br><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Impfkristallisations-Technologien\"><\/span>Impfkristallisations-Technologien<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Wasserh\u00e4rte \u00e4ndert sich bei keiner der nachfolgenden Technologien. Allerdings lagert sich Kalk nur noch stark vermindert ab, da das CaCO<sub>3<\/sub> bereits in stabilen feinen Mikro- oder sehr feinen Nanokristallen gebunden vorliegt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"TAC\"><\/span>TAC<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Template Assisted Crystallization<\/em> &#8211; Tr\u00e4ger des Kristallisationskeimes ist ein festes Medium, z.B. Harz oder Granulat. Auf diesen bilden sich beim Durchstr\u00f6men des Wassers Calciumcarbonat-Kristalle, die sich umgehend vom Medium abl\u00f6sen und mit dem Awasser fortgeleitet werden.<br>Ideal bei geringerem Durchfluss, da die Bildung der Mikro- im Vergleich zu Nanokristallen beim NAC-Verfahren mehr Zeit beansprucht.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"NAC\"><\/span>NAC<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Nucleation Assisted Crystallization<\/em> &#8211; prinzipiell identisch mit dem TAC-Verfahren, jedoch werden hier Nano- statt Microkristalle erzeugt. D.h. die Partikelzahl ist gr\u00f6\u00dfer, die Kristalle kleiner.<br>Vorteilhaft, wenn hoher Durchfluss gefordert ist, da die Kontaktzeit zum Medium deshalb k\u00fcrzer ist und die Kristallbildung systembedingt schneller als beim TAC-Verfahren abl\u00e4uft.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"MAC\"><\/span>MAC<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Media Assisted Crystallization<\/em> &#8211; fasst beide Verfahren, TAC und NAC, unter einem \u00dcberbegriff zusammen. Die Bezeichnung MAC wird meist dann verwendet, wenn eigene Technologien in anwendung kommen, die sich von \u00fcblichen TAC-\/NAC-Verfahrenstechnolgien unterscheiden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Anbieter_von_Systemen_mit_Impfkristallisation\"><\/span>Anbieter von Systemen mit Impfkristallisation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wie immer gilt es die Spreu vom Weizen zu trennen, sprich: welcher Hersteller behauptet nicht nur, sondern belegt auch die Funktion seiner Produkte mit entsprechenden Zertifikaten unabh\u00e4ngiger Pr\u00fcfstellen und \/ oder Studien.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Kontaktzeit des durchstr\u00f6menden Wassers ist, wi evor erw\u00e4hnt, funktional bedeutsam, weshalb die Datenbl\u00e4tter der einzelnen Produkte hinsichtlich dieses Kriteriums gesondert zu bewerten sind und die Gesamtanlage darauf abszustimmen ist.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nachfolgende Hersteller fallen hier positiv auf:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.scalestopplus.com\/technology.html\" target=\"_blank\" rel=\"noreferrer noopener\">ScaleStop<\/a> &#8211; <a href=\"mailto:support@scalestopplus.com\">support@scalestopplus.com<\/a><br>Unabh\u00e4ngige Tests der <a href=\"https:\/\/scalestopplus.com\/alternatives-to-domestic-ion-exchange-water-softeners.html\" target=\"_blank\" rel=\"noreferrer noopener\">Arizona State University<\/a> und DVGW (W512 aus 2013) belegen die Wirksamkeit mit jeweils 99%<\/li>\n\n\n\n<li><a href=\"https:\/\/www.watertechgroup.com\/en\/\" target=\"_blank\" rel=\"noreferrer noopener\">Water Tech<\/a> &#8211; <a href=\"mailto:info@watertechgroup.com\">info@watertechgroup.com<\/a><br>bewirbt sein Produkt <a href=\"https:\/\/www.watertechgroup.com\/images\/Datasheets\/equipment\/softeners-systems\/Water-Tech-SCALE-SAFE-Tech-Description.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Scale-Safe<\/a> mit einer 99,9-prozentigen Wirksamkeit<\/li>\n\n\n\n<li><a href=\"https:\/\/www.aqon-pure.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">Aqon Pure<\/a> &#8211; <a href=\"mailto:info@aqon-pure.com\">info@aqon-pure.com<\/a><br>belegt die Wirksamkeit ihres Systems mit zwei Studien: der <a href=\"https:\/\/cdn.prod.website-files.com\/65016903de2eec3e906d6c6c\/66e94d8ce9395c7575fed121_Hohenstein_24.8.6.0005_AQON.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Hohenstein Innovations gGmbH<\/a> und der GSA (<a href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0840\/0581\/4600\/files\/aqon-pure-wirkung-gsa-uebersicht.pdf?v=1730200527\" target=\"_blank\" rel=\"noreferrer noopener\">Link 1<\/a>, <a href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0840\/0581\/4600\/files\/aqon-pure-wirkung-gsa-kurzbericht.pdf?v=1730200500\" target=\"_blank\" rel=\"noreferrer noopener\">Link 2<\/a>, <a href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0840\/0581\/4600\/files\/aqon-pure-wirkung-gsa-bericht.pdf?v=1730200468\" target=\"_blank\" rel=\"noreferrer noopener\">Link 3<\/a>)<\/li>\n\n\n\n<li><a href=\"https:\/\/www.watts.eu\/\" target=\"_blank\" rel=\"noreferrer noopener\">Watts<\/a> &#8211; <a href=\"mailto:info@wattsindustries.it\">info@wattsindustries.it<\/a><br>bietet eine Produktreihe unter der Bezeichnung <a href=\"https:\/\/www.watts.eu\/en\/products\/eu\/anti-scale-system-oneflow\" target=\"_blank\" rel=\"noreferrer noopener\">One-Flow<\/a> an<\/li>\n\n\n\n<li><a href=\"https:\/\/crystalwash.fr\" target=\"_blank\" rel=\"noreferrer noopener\">Crystal Wash<\/a> &#8211; <a href=\"mailto:clean@crystalwash.fr\">clean@crystalwash.fr<\/a><br>beschr\u00e4nkt sich auf eine <a href=\"https:\/\/crystalwash.fr\/crystal-wash-ultra-pure-wash-system\/softners\/\" target=\"_blank\" rel=\"noreferrer noopener\">Wirksamkeitsangabe von 88 .. 97 %<\/a> und bezieht sich auf die generell durch DVGW-W512 ausgewiesene Effizenz des TAC-Verfahrens<br><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ergiebigkeit_der_Quelle\"><\/span><strong>Ergiebigkeit der Quelle<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bei einer vorhandenen oder geplanten Brunnenbohrung sind die Parameter Durchfluss- und Entnahmerate, neben anderen Parametern in der Berechnung der zu entnehmenden Grundwassermenge in der Zeiteinheit elementar. Die Erl\u00e4uterung, samt Berechnung findet sich sehr anschaulich auf dieser <a href=\"https:\/\/www.grundwasser.net\/\" target=\"_blank\" rel=\"noopener\">Webseite<\/a>.<br><br>Die Entnahme von Wasser aus einem Fluss ist oft genehmigungspflichtig und wird mengenm\u00e4\u00dfig begrenzt festgelegt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Auswahl_der_Forderpumpe\"><\/span><strong>Auswahl der F\u00f6rderpumpe<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Eine Tiefbrunnenpumpe dient der F\u00f6rderung von Grundwasser aus Tiefen zwischen 8 und 90 Metern. Zu beachten ist, dass die Entnahmeh\u00f6he und Pumpentiefe (Ansaugtiefe) addiert die Gesamtf\u00f6rderh\u00f6he ergeben.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Anwendungs-<em>Beispiel<\/em>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Pumpentiefe (Saugkorb) 20 m + h\u00f6chster Entnahmepunkt 30 m = 50 m betr\u00e4gt die gesamte F\u00f6rderh\u00f6he der Tiefbrunnenpumpe<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Allerdings sind, neben der reinen H\u00f6hendifferenz, auch Reibungsverluste der Leitungsf\u00fchrung (Rauhigkeit des Rohres, Formst\u00fccke, etc. = dynamischer Kopf) zu ber\u00fccksichtigen. Diese m\u00fcssen entsprechend bei der Pumpenauswahl aufgeschlagen werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ausgehend von einer Pumpenleistung von 3.000 l\/h (Q = 3\/3600 m<sup>3<\/sup>\/s =&nbsp;0,0008333333333333333 m<sup>3<\/sup>\/s), unter der Verwendung von z.B. DN65 (D = 0,0752) PE\/HDPE-Rohr mit einer Rauhigkeit lt. Datenblatt von \u03b5 = 1,5 \u00b5m = 1,5 \u00d7 10\u207b\u2076 m, der kinematische Viskosit\u00e4t von Wasser von \u2248 1\u00b710<sup>-6<\/sup> m\u00b2\/s, sowie einer Dichte \u03c1 = 1000 kg\/m<sup>3<\/sup> und Flie\u00dfgeschwindigkeit von g = 9,81 m\/s<sup>2<\/sup>, sowie Ber\u00fccksichtigung der \u00c4quivalente von Fittingen, etc. durch das kalkulierte 1,2-Fache der Leitungsl\u00e4nge von 200 m, entsprechend 240 m und zu \u00fcberwindendem H\u00f6henunterschied von H<sub>s<\/sub> 50 m (statischer Kopf) bei einer mittleren Erdbeschleunigung von g = 9,81 m\/s<sup>2<\/sup> (als Konstante), ergibt sich folgende Rechnung:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Querschnitt DN65<\/strong><br>A = ( \u03c0 \u22c5 D<sup>2<\/sup> ) : 4 = ( \u03c0 \u22c5 0,0752 <sup>2<\/sup> ) : 4 = 0,004417865&nbsp;m<sup>2<\/sup><\/li>\n\n\n\n<li><strong>Str\u00f6mungsgeschwindigkeit<\/strong><br>v = Q : A = 0,0008333333333333333 m<sup>3<\/sup>\/s : 0,004417865&nbsp;m<sup>2<\/sup> = 0,1886280807&nbsp;m\/s<\/li>\n\n\n\n<li><strong>Reynoldszahl<\/strong> (Kennzahl, niedrig = laminare, hoch = turbulente Str\u00f6mung)<br>Re = \u03c5D : v = ( 0,1886280807015056 \u22c5 0,0752 ) : ( 1\u22c510\u22126&nbsp;m<sup>2<\/sup>\/s ) = 14147,10605261292&nbsp;m<sup>2<\/sup>\/s<\/li>\n\n\n\n<li><strong>Rohrreibungsbeiwert<\/strong> (Swamee-Jain)<br>f = 0,25 : [ log<sub>10<\/sub> ( (\u03b5 : ( 3,7 \u22c5 D )) + ( 5,74 : Re<sup>0,9<\/sup> ) ) ]<sup>2<\/sup><br>f = 0,25 : [ log<sub>10<\/sub> ( 5,405405405405405 \u00d7 10<sup>-6<\/sup> + 0,000728728 ) ]<sup>2<\/sup><br>f = 0,25 : [ log<sub>10<\/sub> ( 0,0007341334054054 ) ]<sup>2<\/sup><br>f = 0,25 : [ \u22123,134490 ]<sup>2<\/sup><br>f = 0,25 : 9,825866 = 0,028256663933258565<\/li>\n\n\n\n<li><strong>Rohrreibungsverlust<\/strong> (Darcy-Weisbach)<br>h<sub>f&nbsp;<\/sub> = f \u22c5 ( L : D ) \u22c5 ( v<sup>2<\/sup> : 2g )<br>h<sub>f&nbsp;<\/sub> = f \u22c5 ( 240 : 0,075 ) \u22c5 ( 0,1886280807015056<sup>2<\/sup> : 2 \u22c5 9,81 )<br>h<sub>f&nbsp;<\/sub> = f \u22c5 ( 3.200 ) \u22c5 ( 0,001813634&nbsp;m )<br>h<sub>f&nbsp;<\/sub> = 0,028256663933258565 \u22c5 5,803629 = \u2248 0,1639776104&nbsp;m<\/li>\n\n\n\n<li><strong>\u00c4quivalenter Formst\u00fcckverlust<\/strong><br>(identische Fommel, statt L (Rohrl\u00e4nge) wird L<sub>eq<\/sub> (mit 10 m gesetzt)<br>h<sub>eq<\/sub> = f \u22c5 ( L<sub>eq<\/sub> : D ) \u22c5 ( v<sup>2<\/sup> : 2g ) = \u22480,0068324004&nbsp;m<\/li>\n\n\n\n<li><strong>Gesamtf\u00f6rderh\u00f6he<\/strong><br>H<sub>tot<\/sub> = H<sub>s<\/sub> + h<sub>f&nbsp;<\/sub> + h<sub>eq<\/sub><br>H<sub>tot<\/sub> = 50,0 m + 0,1639776104&nbsp;m + 0,0068324004&nbsp;m = \u224850,1708100&nbsp;m<\/li>\n\n\n\n<li><strong>Druck am Ausgang der Pumpe<\/strong><br>p = \u03c1gH<sub>tot<\/sub><br>p = 1000\u22c59,81\u22c550,1708100108 = 492175.6462064206&nbsp;Pa<br>p = 492175.6462064206&nbsp;Pa : 10.000 = 4,921756462064206&nbsp;bar<\/li>\n\n\n\n<li><strong>Hydraulische Pumpen-Leistung<\/strong><br>P<sub>h\u200b<\/sub> = \u03c1gQH<sub>tot<\/sub><br>P<sub>h\u200b<\/sub> = 1000 \u22c5 9,81 \u22c5 0,0008333333333333333 \u22c5 50,1708100108 = 410,1463718386839&nbsp;W<\/li>\n\n\n\n<li><strong>Elektrische Motorleistung<\/strong>&nbsp;P<sub>motor\u200b&nbsp;<\/sub>bei Wirkungsgrad \u03b7 = 0,65<br>P<sub>motor<\/sub>\u200b = Ph\u200b\u200b : \u03b7<br>P<sub>motor<\/sub>\u200b = 410,1463718386839 : 0,65 = 630,9944182133598&nbsp;W<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Nominell erbringt eine Pumpe mit rund 630 W die erforderliche Leistung. In der Praxis geht man, mit einem 80-prozentigen Aufschhlag als Sicherheitsreserve, also von etwa 1,1 kW aus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ventile\"><\/span>Ventile<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn jede Zisterne im Verbund einzeln trennbar sein soll, was im Falle von bei Wartungsarbeiten oder Leckagen sinnvoll ist, ben\u00f6tigt man f\u00fcr jede Zisterne ein Absperr- und R\u00fcckschlagventil, sowie ein Sp\u00fcl-, bzw. Entleerungsventil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Motorisch betriebene Ventile sollten \u00fcber die M\u00f6glichkeit einer manuellen (Not-)Bet\u00e4tigung verf\u00fcgen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alle Komponenten m\u00fcssen bei Trinkwasser-Anforderung WRAS\/DVGW-konform ausgelegt sein (EPDM-Sitz und NBR-Membran). Montageflansche f\u00fcr die Anbindung von Aktuatoren m\u00fcssen gem\u00e4\u00df ISO 5211, Motorflansche entsprechend ISO5211 F05\/F07 ausgelegt sein.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Leckrate sollte gem\u00e4\u00df <strong>Klasse VI<\/strong> sein, was absolute (blasenfreie) Dichtigkeit bedeutet, mithin einer Leckrate von Null entspricht. Alle Ventilen mit (PTFE-) \/ EPDM-Sitz erf\u00fcllen diese Forderung.<br>Metallsitze erreichen nur Klasse IV: eine Leckrate von 10 ml\/min unter Pr\u00fcfdruck ist erlaubt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ob 230 V AC- oder 24 V DC-(Batterie-)Betrieb der Aktuatoren entscheidet die Forderung einer automatisierten Bedienbarkeit auch bei Ausfall des \u00f6ffentlichen Strom-Versorgungsnetzes.<br>Alle elektrischen Komponenten m\u00fcssen bei, der Witterung ausgesetzten, Anlagen nach <strong>IP65<\/strong> (staubdicht, Schutz gegen Strahlwasser), besser <strong>IP67<\/strong> ( Staubdicht, Schutz gegen kurzzeitiges Untertauchen) zugelassen sein.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Motorisch betriebene Ventile m\u00fcssen \u00fcber Endschalter, idealerweise eine Ansteuerung \u00fcber 0 .. 10 V, resp. 4 .. 20 mA verf\u00fcgen, wenn andere Positionen als offen \/ geschlossen angesteuert werden sollen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Fullstands-Messung\"><\/span>F\u00fcllstands-Messung<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr die F\u00fcllstands\u00fcberwachung bieten sich Ultraschall- und Drucksensoren an. W\u00e4hrend Drucksensoren, am Zisternenboden positioniert, st\u00e4ndig Wasser ausgesetzt sind, ist die Ultraschall-Messung ber\u00fchrungslos: Der Sensor wird am oder unter dem Zisternendeckel montiert und ist damit schnell zug\u00e4nglich.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industrielle Ultraschallsensoren geben als Signal einen Strom von 4 .. 20 mA aus, der \u00fcber enen kalibrierten IU-Wandler (Strom zu Spannung) eine messwertabh\u00e4ngige Spannung erzeugt, die \u00fcber einen Mikrokontroller ausgewertet und als Messwert, in Liter, Kubikmeter oder Prozent umgerechnet, angezeigt wird.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Allerdings steigen die Preise f\u00fcr Ultraschallsensoren analog der zunehmenden Reichweite bis in den vierstelligen Euro-Bereich. Sensoren mit bis zu 2,2 m Messdistanz liegen um die <a href=\"https:\/\/autosen.com\/de\/Positionssensoren\/Ultraschallsensoren\/Ultraschallsensor-AU007\" target=\"_blank\" rel=\"noreferrer noopener\">200 Euro<\/a>, was die Zisternentiefe auf etwa 2 m begrenzt, soll das Budget nicht \u00fcberstrapaziert werden.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">\u8aad\u66f8\u6642\u9593<\/span> <span class=\"rt-time\"> 6<\/span> <span class=\"rt-label rt-postfix\">\u8b70\u4e8b\u9332<\/span><\/span>Die Planung von Trinkwasser-Zisternen umfasst mehrere physikalische Gegebenheiten, die es zu ber\u00fccksichtigen gilt, will man mit m\u00f6glichst geringem Aufwand die gew\u00fcnschte Trinkwasser-Qualit\u00e4t und F\u00f6rderleistung erzielen. Wasser-Analyse und Grenzwerte Zun\u00e4chst ist von jeder Wasserquelle eine Laboranalyse zu fertigen, mittels derer die Wasserwerte mit den geltenden Grenzwerten verglichen werden, um ggf. gezielt Ma\u00dfnahmen zur Einhaltung derselben ergreifen zu k\u00f6nnen: Wasserh\u00e4rte Die Wasserh\u00e4rte repr\u00e4sentiert den Gehalt von Calciumcarbonat (CaCO\u2083) in mmol\/l, ppm oder mg\/l (1 mmol\/l = 1 ppm\/l = 1 mg\/l) Erdalkali-Ionen gem\u00e4\u00df dem internationalen Einheitssystem SI (Syst\u00e8me International d&#8217;Unit\u00e9s), veraltet auch noch in \u00b0dH (deutsche H\u00e4rte 1 \u00b0dH entspricht 0,1783 mml\/l), angegeben. Die Wasserh\u00e4rte zeigt sich u.a. in Kalkablagerungen in Leitungen,&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/ja\/blog\/2025\/11\/19\/planung-von-trinkwasser-zisternen\/\" rel=\"bookmark\">\u7d9a\u304d\u3092\u8aad\u3080 \"<span class=\"screen-reader-text\">\u98f2\u6599\u6c34\u8caf\u6c34\u69fd\u306e\u8a08\u753b<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-11640","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/posts\/11640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/comments?post=11640"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/posts\/11640\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/media?parent=11640"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/categories?post=11640"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/ja\/wp-json\/wp\/v2\/tags?post=11640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}