{"id":11434,"date":"2025-10-07T17:09:47","date_gmt":"2025-10-07T17:09:47","guid":{"rendered":"https:\/\/csiag.eu\/?p=11434"},"modified":"2025-10-07T17:54:09","modified_gmt":"2025-10-07T17:54:09","slug":"dizaino-pertvarkymas-subdistribucija","status":"publish","type":"post","link":"https:\/\/csiag.eu\/lt\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/","title":{"rendered":"Pakopinio paskirstymo plok\u0161t\u0117s pertvarkymas"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Turinys<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/lt\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Durchgangsklemmen-Installationskasten\" >Perdavimo gnybt\u0173 montavimo d\u0117\u017eut\u0117<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/lt\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Verteilerschrank\" >Paskirstymo spinta<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/lt\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Leistungsmessung\" >Galios matavimas<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Skaitymo laikas<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minut\u0117s<\/span><\/span>\n<p>Perprojektuoti namo paskirstymo skyd\u0105 gali b\u016bti tikslinga \u012fvairiais atvejais: pavyzd\u017eiui, visi\u0161kai atnaujinant elektros instaliacij\u0105 arba kei\u010diant sen\u0105 saugikli\u0173 sistem\u0105 nauja, galb\u016bt su RCD (-ais).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Durchgangsklemmen-Installationskasten\"><\/span>Perdavimo gnybt\u0173 montavimo d\u0117\u017eut\u0117<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Abiem atvejais senieji kabeliai pasirodo per trumpi, tod\u0117l jie sutrumpinami iki standartizuoto tinkamo ilgio ir, pavyzd\u017eiui, naudojant PHOENIX-CONTACT UT 2.5 BU per\u0117jimo gnybtus, perduodami \u012f tolimesnes \u0161ynas, automatines ma\u0161inas ir pan.<\/p>\n\n\n\n<p>Jei na\u0161umas didesnis nei 2,5 mm<sup>2<\/sup>Jei laidams tiesti reikia naudoti 2,5 mm \u012fvadinius gnybtus, jie turi b\u016bti naudojami vietoj 2,5 mm \u012fvadini\u0173 gnybt\u0173. Kabeliai taip pat turi b\u016bti suprojektuoti reikiamo skerspj\u016bvio.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"900\" height=\"511\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_.png\" alt=\"\" class=\"wp-image-11436\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_.png 900w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-300x170.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-768x436.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-18x10.png 18w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n<p>Jei naujoji paskirstymo plok\u0161t\u0117 yra siauresn\u0117 u\u017e ankstesni\u0105j\u0105, rekomenduojama \u012frengti atskir\u0105 pla\u010di\u0105 1 eil\u0117s paskirstymo plok\u0161t\u0119.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verteilerschrank\"><\/span>Paskirstymo spinta<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Paskirstymo spintos dydis priklauso nuo papildom\u0173 montuojam\u0173 komponent\u0173. Trij\u0173 fazi\u0173 sistemose ji turi b\u016bti 4 eili\u0173.<\/p>\n\n\n\n<p>Pirmoje eil\u0117je yra 5 poli\u0173 pagrindin\u0117s linijos at\u0161akos gnybtas (trims faz\u0117ms, neutraliajam ir \u012f\u017eeminimo laidininkui), 3 poli\u0173 pagrindinis jungiklis (trims faz\u0117ms) ir 4 poli\u0173 RCD (neutraliajam laidininkui ir trims faz\u0117ms). \u0160ios trys eil\u0117s yra priskirtos trims faz\u0117ms ir jose \u012frengti atitinkami jungikliai.<\/p>\n\n\n\n<p>\u012eprastai visi kabeliai \u012feina i\u0161 vir\u0161aus. Kai kuriais montavimo atvejais kabeliai \u012f paskirstymo d\u0117\u017eut\u0119 gali patekti ir i\u0161 apa\u010dios.<br>Kad nereik\u0117t\u0173 vis\u0173 kabeli\u0173 u\u017e automat\u0173 eili\u0173 tiesti \u012f vir\u0161utin\u012f auk\u0161t\u0105 (paprastai tai sud\u0117tinga d\u0117l ribotos vietos u\u017e DIN b\u0117gi\u0173), paskutini\u0173j\u0173 trij\u0173 eili\u0173 gale taip pat yra \u012fvadiniai gnybtai, i\u0161 kuri\u0173 kabelius galima patogiai i\u0161vesti \u012f vir\u0161\u0173 palei kra\u0161t\u0105.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"510\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-510x1024.png\" alt=\"\" class=\"wp-image-11437\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-510x1024.png 510w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-149x300.png 149w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-6x12.png 6w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler.png 600w\" sizes=\"(max-width: 510px) 100vw, 510px\" \/><\/figure>\n<\/div>\n\n\n<p>Ir baigtas paskirstymas...<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"433\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-433x1024.png\" alt=\"\" class=\"wp-image-11448\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-433x1024.png 433w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-127x300.png 127w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-5x12.png 5w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl.png 600w\" sizes=\"(max-width: 433px) 100vw, 433px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leistungsmessung\"><\/span>Galios matavimas<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Jei norite ne tik skaitiklio ekrane matyti bendr\u0105 suvartojim\u0105, bet ir su\u017einoti suvartojim\u0105 atskirais etapais, galite naudoti \u012fvairius prietaisus, kurie apima \u012fvairias programas ir patogiai rodo duomenis naudodami program\u0117l\u0119.<\/p>\n\n\n\n<p>Ta\u010diau tokius prietaisus patartina naudoti ne tik d\u0117l ai\u0161kumo, bet vis\u0173 pirma siekiant nustatyti i\u0161 esm\u0117s tolyg\u0173 atskir\u0173 fazi\u0173 panaudojim\u0105.<\/p>\n\n\n\n<p>Jei norite toliau apdoroti duomenis arba, pavyzd\u017eiui, tam tikru metu ir priklausomai nuo faz\u0117s naudojimo perjungti vartotojus, pavyzd\u017eiui, transporto priemon\u0117s \u012fkrovimo proces\u0105, tur\u0117tum\u0117te \u012fsitikinti, kad \u012frengin\u012f taip pat galima integruoti \u012f tokius i\u0161maniuosius namus ir kad palaikomas reikiamas protokolas, pavyzd\u017eiui, \"Shelly\" produktai.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"712\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1024x712.png\" alt=\"\" class=\"wp-image-11438\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1024x712.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-300x208.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-768x534.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1536x1067.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-2048x1423.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-18x12.png 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>\u0160is prietaisas yra dviej\u0173 versij\u0173: \u201eT\u201c rei\u0161kia gnybt\u0173 jungtis, skirtas tiesioginiam montavimui ant RCD. \u201eW\u201c variante vietoj kiekvieno lizdo yra kabelis su kabelio galiniu antgaliu.<\/p>\n\n\n\n<p>Tiek suvartojim\u0105, tiek maitinim\u0105 vienodai fiksuoja indukciniai jutikliai, esantys RCD tinklo matmen\u0173 korpuse.<\/p>\n\n\n\n<p>Montuojant reikia steb\u0117ti srov\u0117s srauto krypt\u012f, kad neb\u016bt\u0173 u\u017eregistruota i\u0161eiga, kuri i\u0161 tikr\u0173j\u0173 tur\u0117t\u0173 b\u016bti priskirta vartojimo pusei... - Atitinkamai \u201eL\u201c rei\u0161kia vartojimo pus\u0119, \u201eK\u201c - tiekimo \/ maitinimo pus\u0119 (PV).<\/p>\n\n\n\n<p>Kiekviena faz\u0117 prie trij\u0173 ki\u0161tuko kontakt\u0173 jungiama trimis kabelio antgaliais, taip pat prijungiamas nulinis laidininkas.<br>Faz\u0117s turi b\u016bti apsaugotos greitai veikian\u010diais 100 mA 20\u00d75 mm stikliniais saugikliais atitinkamuose saugikli\u0173 laikikliuose. Sakoma, kad yra buv\u0119, jog toks \u012frenginys tyliai u\u017esideg\u0117 ...<\/p>\n\n\n\n<p>\u012erenginio nustatymas yra tikrai paprastas ir patogus. Naudodami program\u0105, kuri\u0105 galima atsisi\u0173sti i\u0161 atitinkamos program\u0173 parduotuv\u0117s per QR kod\u0105, per \"Bluetooth\" prisijungiate prie \u012frenginio, kuris i\u0161 karto atpa\u017e\u012fstamas. Tuomet si\u016blomas prisijungimas prie vietinio WLAN. Patvirtinus atitinkamas saugumo u\u017eklausas, prietaisas prisijungia prie nam\u0173 \"Wi-Fi\" tinklo ir nuo tada juo galima naudotis.<\/p>\n\n\n\n<p>Vartojimo duomen\u0173 rodymas program\u0117l\u0117je yra ai\u0161kus, nors ir ne\u012fsp\u016bdingai suprojektuotas.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"989\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1024x989.png\" alt=\"\" class=\"wp-image-11439\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1024x989.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-300x290.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-768x742.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1536x1484.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-2048x1979.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-12x12.png 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-text-align-center\">Visa informacija be garantijos - elektros sistem\u0173 montavimo darbus gali atlikti tik \u012fgalioti specialistai!<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Skaitymo laikas<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minut\u0117s<\/span><\/span>Eine Unterverteilung im Haus neu zu gestalten kann im verschiedenen F\u00e4llen sinnvoll sein: so z.B. bei einer vollst\u00e4ndigen Erneuerung der elektrischen Verkabelung oder auch, um eine alte Sicherungsanlage durch eine neue ggf. mit FI-Schalter(n) zu ersetzen. Durchgangsklemmen-Installationskasten In beiden F\u00e4llen erweisen sich die alten Kabel als zu kurz, weshalb man diese auf eine einheitlich passende&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/lt\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/\" rel=\"bookmark\">Skaityti daugiau \"<span class=\"screen-reader-text\">Pakopinio paskirstymo plok\u0161t\u0117s pertvarkymas<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1],"tags":[5494,551,5488,5490,5489,5486,5485,5484,5497,813,5482,5493,5088,389,5487,812,5498,5495,5496,1062,981,370,5481,3388,2621,2536,5483,563],"class_list":["post-11434","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-auslastung","tag-bt","tag-durchgangsklemmen","tag-einspeisedaten","tag-einspeisung","tag-fehlerstromschutzschalter","tag-fi-schalter-2","tag-galssicherung","tag-hauptleitungs-abzweigklemme","tag-installation","tag-installationskasten","tag-ladevorgang","tag-last","tag-leistungsmessung","tag-phoenix-contact","tag-photovoltaik","tag-pv","tag-shelly","tag-shelly-gen3","tag-sicherung","tag-sicherungsautomat","tag-smarthome","tag-unterverteilung","tag-verbrauch","tag-verbrauchsdaten","tag-verteiler","tag-verteilerschrank","tag-wlan"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts\/11434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/comments?post=11434"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts\/11434\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/media?parent=11434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/categories?post=11434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/tags?post=11434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}