{"id":4373,"date":"2023-05-12T17:19:13","date_gmt":"2023-05-12T17:19:13","guid":{"rendered":"https:\/\/csiag.eu\/?p=4373"},"modified":"2023-06-15T19:51:58","modified_gmt":"2023-06-15T19:51:58","slug":"smartmetras-padeda-isvengti-elektrosmogo","status":"publish","type":"post","link":"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/","title":{"rendered":"I\u0161manusis matuoklis - venkite elektrosmogo"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Turinys<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Rundsteuer-Empfanger\" >Ripple control imtuvas<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Datenubertragungsverfahren_und_Frequenzen\" >Duomen\u0173 perdavimo b\u016bdai ir da\u017eniai<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Mobilfunknetz\" >Mobilusis tinklas<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#PLC\" >PLC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#DSL\" >DSL<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Fazit\" >I\u0161vada<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Skaitymo laikas<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minut\u0117s<\/span><\/span>\n<p class=\"wp-block-paragraph\">I\u0161manieji skaitikliai - aktuali \u0161i\u0173 dien\u0173 tema, ypa\u010d susijusi su elektrosmogu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Seni geri mechaniniai \"Ferraris\" skaitikliai taps atgyvena ir bus pakeisti i\u0161maniaisiais elektroniniais skaitikliais, vadinamaisiais protingais skaitikliais. Taip siekiama sutaupyti darbuotoj\u0173, kurie skait\u0117 senuosius skaitiklius. Be to, did\u017eiul\u0117 administracin\u0117 na\u0161ta buvo palikti skaitiklio rodmen\u0173 kortel\u0119, kai klientai nedalyvaudavo skaitiklio rodmen\u0173 nuskaitymo metu, kuri\u0105 klientas kartu su skaitiklio rodmenimis tur\u0117jo nusi\u0173sti komunalini\u0173 paslaug\u0173 \u012fmonei, kad ji b\u016bt\u0173 rankiniu b\u016bdu perkelta \u012f IT sistem\u0105 ir tada b\u016bt\u0173 galima sukurti s\u0105skait\u0105.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I\u0161mani\u0173j\u0173 skaitikli\u0173 pradininkai - tai elektroniniai \u0161ilumos aptikimo prietaisai, kuriuos gali nuskaityti pro butus va\u017eiuojanti transporto priemon\u0117 su atitinkama \u012franga. Tai greitesnis b\u016bdas nei rankinis registravimas, be to, jis nepriklauso nuo galimo pri\u0117jimo prie butuose esan\u010di\u0173 radiatori\u0173.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dabar i\u0161mani\u0173j\u0173 skaitikli\u0173 duomenys turi b\u016bti registruojami centralizuotai, penkiolikos minu\u010di\u0173 intervalais, t. y. ne tik atsiskaitymo laikotarpio pabaigoje, kaip paprastai b\u016bna po vieneri\u0173 met\u0173.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u0117l to duomen\u0173 apsaugos specialistai sukilo. Galiausiai galima steb\u0117ti vartojimo elges\u012f, \u012fskaitant buvim\u0105 ar nebuvim\u0105, ir tuo galima piktnaud\u017eiauti. Be to, tiek\u0117jas taip pat gal\u0117t\u0173 nuotoliniu b\u016bdu i\u0161jungti elektros energijos tiekim\u0105 ir daugel\u012f kit\u0173 dalyk\u0173 b\u016bt\u0173 labai lengva \u012fgyvendinti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rundsteuer-Empfanger\"><\/span>Ripple control imtuvas<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u012etamp\u0173 valdymo imtuvai naudojami automati\u0161kai reguliuoti \u012f tinkl\u0105 tiekiam\u0173 fotovoltini\u0173 sistem\u0173 gali\u0105 ir yra skirti u\u017ekirsti keli\u0105 perteklinei gamybai, o kartu ir tinklo da\u017enio nuokrypiams \u012f vir\u0161\u0173.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Jei \u012fprastinis 50 Hz da\u017enis nukrypsta \u012f vir\u0161\u0173 vos 0,2 Hz, fotovoltini\u0173 sistem\u0173 galia nuotolinio valdymo komanda suma\u017einama ir visi\u0161kai i\u0161jungiama esant 51,5 Hz da\u017eniui.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">BPR valdikliai gal\u0117t\u0173 atpa\u017einti perteklin\u0119 gamyb\u0105 ir perteklin\u0119 energij\u0105 nukreipti protingiau, pavyzd\u017eiui, \u012f buferini\u0173 rezervuar\u0173 \u0161ildymo ritinius, kad ji b\u016bt\u0173 paversta \u0161iluma, o ne sunaikinta droseliais arba visi\u0161kai i\u0161jungta.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Datenubertragungsverfahren_und_Frequenzen\"><\/span>Duomen\u0173 perdavimo b\u016bdai ir da\u017eniai<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">I\u0161manieji skaitikliai duomenis komunalini\u0173 paslaug\u0173 \u012fmonei gali perduoti \u012fvairiais b\u016bdais. Tai gali b\u016bti daroma per mobiliojo ry\u0161io tinkl\u0105 (naudojant tiek\u0117jo SIM kortel\u0119, integruot\u0105 \u012f i\u0161man\u0173j\u012f skaitikl\u012f), PLC (Power Line Communication) arba laidiniu DSL ry\u0161iu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Mobilfunknetz\"><\/span>Mobilusis tinklas<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Duomenys mobili\u0173j\u0173 telefon\u0173 tinkle perduodami impulsiniais duomen\u0173 paketais. Kad visada b\u016bt\u0173 u\u017etikrintas ry\u0161ys su artimiausiu mobiliojo ry\u0161io stulpu, i\u0161manusis skaitiklis periodi\u0161kai siun\u010dia blokavimo skambut\u012f. D\u0117l to kas kelias sekundes patiriamas radiacijos poveikis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Galimi \u0161ie HF da\u017eniai (auk\u0161tas da\u017enis) su skirtingais da\u017eni\u0173 juostos plo\u010diais nuo 10 iki 100 MHz:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>5G da\u017eni\u0173 juosta SA \/ 700 MHz<\/li>\n\n\n\n<li>LTE 28 \/ 700 MHz da\u017eni\u0173 juosta<\/li>\n\n\n\n<li>LTE 20 \/ 800 MHz da\u017eni\u0173 juosta<\/li>\n\n\n\n<li>GSM \/ 890-915 MHz<\/li>\n\n\n\n<li>LTE 8 da\u017eni\u0173 juosta \/ 900 MHz<\/li>\n\n\n\n<li>GSM 900 \/ 935-960 MHz<\/li>\n\n\n\n<li>LTE 32 da\u017eni\u0173 juosta \/ 1 500 MHz<\/li>\n\n\n\n<li>LTE 3 da\u017eni\u0173 juosta \/ 1 800 MHz<\/li>\n\n\n\n<li>LTE 1 da\u017eni\u0173 juosta \/ 2100 MHz<\/li>\n\n\n\n<li>LTE 7 ir 38 da\u017eni\u0173 juostos \/ 2600 MHz <\/li>\n\n\n\n<li>5G da\u017eni\u0173 juosta N78 \/ 3,400-3,800 GHz <\/li>\n\n\n\n<li>5G da\u017eni\u0173 juosta N85 \/ 26 GHz ir 60 GHz (abi dar nepaskirtos)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"PLC\"><\/span>PLC<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PLC naudoja elektros linij\u0105 kaip ne\u0161ikl\u012f duomen\u0173 srautams, moduliuotiems OFDM (ortogonaliojo da\u017eni\u0173 pasiskirstymo multipleksavimo) arba QAM (kvadratin\u0117s amplitud\u0117s moduliacijos) technologija \"PolyTrax II\", per\u0161okant per visus galimus da\u017enius.<br>Antenos kabeliai paprastai yra ekranuojami vien\u0105 ar daugiau kart\u0173, kad apsaugot\u0173 faktin\u012f signal\u0105 nuo trukd\u017ei\u0173 kelyje nuo antenos iki imtuvo. Ta\u010diau maitinimo linija n\u0117ra ekranuota, kaip ir prietais\u0173, ki\u0161tukini\u0173 lizd\u0173 ir kt. maitinimo linijos. Tod\u0117l tokie kabeliai tampa antenomis ir laisvai spinduliuoja \u012f aplink\u0105.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pagal vadinam\u0105j\u012f CENELEC standart\u0105 EN 50065-1 (Comit\u00e9 Europ\u00e9en de Normalisation \u00c9lectrotechnique) PLC proced\u016broje naudojami \u0161ie skirtingoms \u0161alims b\u016bdingi skirtingi LF da\u017eni\u0173 diapazonai (\u017eemas da\u017enis):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Virpesi\u0173 valdymo da\u017eni\u0173 diapazonas 110 Hz - 1,6 kHz<\/li>\n\n\n\n<li>- \/ 3 - 9 kHz<\/li>\n\n\n\n<li>A juosta \/ 9-95 kHz<\/li>\n\n\n\n<li>B juosta \/ 95-125 kHz<\/li>\n\n\n\n<li>C juosta \/ 125-140 kHz<\/li>\n\n\n\n<li>D juosta \/ 140 - 148,5 kHz<\/li>\n\n\n\n<li>G3 juosta \/ 155-487 kHz (pvz., \u0160iaur\u0117s Amerika, Japonija)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"DSL\"><\/span>DSL<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I\u0161manieji skaitikliai su LAN s\u0105saja duomenims perduoti naudoja esam\u0105 DSL ry\u0161\u012f, tod\u0117l veikia be radijo signal\u0173. Sveikatos po\u017ei\u016briu jie yra racionaliausia pirmiau min\u0117t\u0173 metod\u0173 alternatyva.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Netzfilter\"><span class=\"ez-toc-section\" id=\"Fazit\"><\/span>I\u0161vada<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Visiems, kurie ken\u010dia nuo jautrumo elektrai (EHS) arba apskritai nori kiek \u012fmanoma labiau i\u0161vengti elektros smogo, patartina pra\u0161yti energijos tiek\u0117jo, kad \u0161is jiems par\u016bpint\u0173 i\u0161man\u0173j\u012f skaitikl\u012f su LAN s\u0105saja, jei tai nei\u0161vengiama.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kita ma\u017eesn\u0117 blogyb\u0117 - i\u0161manusis skaitiklis, naudojantis PLC. \u0160iuo atveju patartina, nors ir brangu, \u012frengti vis\u0173 fazi\u0173 <a href=\"https:\/\/bajog.de\/index.php\/de\/produkte\/netzentst%C3%B6rfilter\/tfskn-filter.html\" target=\"_blank\" rel=\"noreferrer noopener\">Maitinimo tinklo filtras<\/a>pvz. <a href=\"https:\/\/biopowerrief.at\/products\/netzfilter-35-a-fcc\" target=\"_blank\" rel=\"noreferrer noopener\">Tinklo filtras 35 A FCC<\/a> kurie blokuoja PLC da\u017enius ir neleid\u017eia jiems pasiekti vidinio maitinimo \u0161altinio.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Skaitymo laikas<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minut\u0117s<\/span><\/span>I\u0161manieji skaitikliai - aktuali \u0161i\u0173 dien\u0173 tema, ypa\u010d susijusi su elektrosmogu. Seni geri mechaniniai \"Ferraris\" skaitikliai turi tapti atgyvena ir b\u016bti pakeisti i\u0161maniaisiais elektroniniais skaitikliais, vadinamaisiais i\u0161maniaisiais skaitikliais. Taip siekiama sutaupyti darbuotoj\u0173, kurie anks\u010diau nuskaitydavo senuosius skaitiklius. Be to, buvo did\u017eiul\u0117 administracin\u0117 na\u0161ta i\u0161si\u0173sti skaitiklio rodmen\u0173 kortel\u0119, kai skaitiklio rodmen\u0173 nuskaitymo metu klient\u0173 neb\u016bdavo...&nbsp;<a href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/\" rel=\"bookmark\">Skaityti daugiau \"<span class=\"screen-reader-text\">I\u0161manusis matuoklis - venkite elektrosmogo<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1586,1525,1302,1600],"tags":[1702,1704,1604,1587,1703,1526,1708,1706,1549,725,1701,1602,1603,1707,1705,929,1546],"class_list":["post-4373","post","type-post","status-publish","format-standard","hentry","category-elektrosensibilitaet","category-elektrosmog","category-funktechnik","category-smartmeter","tag-5g","tag-bpr-regler","tag-dsl","tag-ehs","tag-elektrohypersensibilitaet","tag-elektrosmog","tag-frequenz-hopping","tag-frequenzen","tag-gsm","tag-lte","tag-mobilfunknetz","tag-netzfilter","tag-plc","tag-polytrax-ii-technik","tag-rundsteuerempfaenger","tag-smartmeter","tag-strahlenbelastung"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts\/4373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/comments?post=4373"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts\/4373\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/media?parent=4373"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/categories?post=4373"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/tags?post=4373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}