{"id":5358,"date":"2023-10-14T17:50:51","date_gmt":"2023-10-14T17:50:51","guid":{"rendered":"https:\/\/csiag.eu\/?p=5358"},"modified":"2023-10-14T17:57:38","modified_gmt":"2023-10-14T17:57:38","slug":"tinklo-technologiju-pataisu-laukas","status":"publish","type":"post","link":"https:\/\/csiag.eu\/lt\/blog\/2023\/10\/14\/netzwerktechnik-patchfeld\/","title":{"rendered":"Tinklo technologija - Komutacinis skydelis"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Skaitymo laikas<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minut\u0117s<\/span><\/span><p>Tinklo technologijose vadinamasis komutacinis skydelis paprastai naudojamas didesniuose \u012frenginiuose. \u012evair\u016bs tinklo kabeliai, vedantys \u012f mar\u0161rutizatorius, komutatorius, ugniasienes ir kitus tinklo komponentus, jungiami priekyje.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5359 aligncenter\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Patchfeld-300x200.jpg\" alt=\"\" width=\"516\" height=\"345\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Patchfeld-300x200.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Patchfeld-930x620.jpg 930w\" sizes=\"(max-width: 516px) 100vw, 516px\" \/><\/p>\n<p>Galin\u0117je dalyje i\u0161 grind\u0173, sienos arba lub\u0173, esan\u010di\u0173 u\u017e tinklo spintos, kurioje sumontuotos \u0161ios jungiamosios plok\u0161t\u0117s, i\u0161vedami oran\u017ein\u0117s spalvos tinklo instaliacijos kabeliai.<\/p>\n<p><a href=\"https:\/\/www.amazon.de\/Netzwerkkabel-Verlegekabel-Halogenfrei-RoHS-Compliant-verbundene-Orange\/dp\/B0849T62N8\/ref=sr_1_1_sspa?crid=N375J4WNZKT&amp;keywords=netzwerk%2Bverlegekabel%2B20m&amp;qid=1697305618&amp;sprefix=netzwewrkverlege%2Caps%2C151&amp;sr=8-1-spons&amp;sp_csd=d2lkZ2V0TmFtZT1zcF9hdGY&amp;th=1\" target=\"_blank\" rel=\"noopener\">Tinklo diegimo kabelis<\/a> galima palyginti, pavyzd\u017eiui, su elektros in\u017einerijoje naudojamais kabeliais su stand\u017eiu apvalkalu, kurie eina i\u0161 atskir\u0173 namo kambari\u0173 ir susijungia skaitikli\u0173 spintel\u0117je. Tinklo instaliacijos kabeliai taip pat yra stand\u016bs, tod\u0117l gali l\u016b\u017eti. Jo lenkimo spindulys yra 35 ... 70 mm, tod\u0117l j\u012f reikia montuoti kabeli\u0173 kanaluose, kuri\u0173 gylis yra ne ma\u017eesnis kaip 70 mm. Pramonin\u0117je ir (arba) komercin\u0117je aplinkoje tai n\u0117ra problema, ypa\u010d tod\u0117l, kad kabeliai paprastai klojami pakeliamose grindyse arba lubose, taip pat parapet\u0173 vamzd\u017eiuose.<\/p>\n<p>Priva\u010diose ir ma\u017eesn\u0117se komercin\u0117se aplinkose, kuriose galima prijungti ne daugiau kaip dvi de\u0161imtis tinklo \u012frengini\u0173, toki\u0173 kaip kompiuteriai, spausdintuvai, skeneriai, prieigos ta\u0161kai ir t. t., komutacinio skydelio nereikia. Be to, ypa\u010d gyvenamuosiuose kambariuose \u017emon\u0117s nenori matyti kabeli\u0173, tod\u0117l juos slepia tokiuose pat nepastebimuose plonuose kabeli\u0173 kanaluose, u\u017e grindjuos\u010di\u0173 arba dur\u0173 zonoje po atitinkamais pra\u0117jimo profiliais. Kadangi standus tinklo instaliacijos kabelis \u010dia neprakti\u0161kas, naudojamas <a href=\"https:\/\/www.amazon.de\/BIGtec-Patchkabel-Netzwerkkabel-Kupferkabel-geschirmt\/dp\/B00IHIZK9S\/ref=sr_1_4?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=2CBNC5AX6XVDG&amp;keywords=bigtec%2Bcat%2B7%2Bnetzwerkkabel%2B10m&amp;qid=1697305680&amp;sprefix=bigtec%2Bcat%2B7%2Bnetzwerkkabel%2B10m%2Caps%2C186&amp;sr=8-4&amp;th=1\" target=\"_blank\" rel=\"noopener\">Lankstus tinklo kabelis<\/a>vadinamasis jungiamasis kabelis su profiliuotais ki\u0161tukais. \u0160is kabelis yra ma\u017eiau jautrus tr\u016bkimo rizikai, netur\u0117t\u0173 b\u016bti susilankst\u0119s, ta\u010diau j\u012f galima tiesti siaurais spinduliais, t. y. net tik 15 mm gylio kabeli\u0173 kanaluose.<\/p>\n<p>Kalbant apie perdavimo technologij\u0105, abiej\u0173 tip\u0173 kabeli\u0173 na\u0161umas nesiskiria, jei j\u0173 kokyb\u0117 yra pana\u0161i.<\/p>\n<h1>Montavimo kabelio montavimas<\/h1>\n<p>I\u0161 anksto sumontuot\u0173 tinklo kabeli\u0173 nereikia montuoti, tiesiog \u012fki\u0161kite juos ir viskas, o montavimo kabeliai neturi suformuot\u0173 ki\u0161tuk\u0173. Jis tiekiamas didel\u0117mis kabeli\u0173 rit\u0117mis ir klojamas kaip ir pirmiau min\u0117tas kabelis su apvalkalu. Apvalkale matote kaban\u010dius galus, kurie laukia, kol bus prijungti prie sujungimo d\u0117\u017eu\u010di\u0173 arba komutacinio skydelio.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-5360 aligncenter\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Kabel-300x204.jpg\" alt=\"\" width=\"513\" height=\"318\" \/><\/p>\n<p>Tinklo instaliacijos kabelis montuojamas naudojant special\u0173 <a href=\"https:\/\/www.amazon.de\/deleyCON-Auflegewerkzeug-Anlegewerkzeug-Netzwerkdosen-Netzwerkverdrahtung\/dp\/B09MQPJLVJ\/ref=sr_1_2_sspa?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=1NRW0J72XFFMH&amp;keywords=auflegewerkzeug&amp;qid=1697305562&amp;sprefix=auflegewerkzeug%2Caps%2C165&amp;sr=8-2-spons&amp;sp_csd=d2lkZ2V0TmFtZT1zcF9hdGY&amp;psc=1\" target=\"_blank\" rel=\"noopener\">Klojimo \u012frankis<\/a> \u012f jungiamosios d\u0117\u017eut\u0117s monta\u017einio bloko pjovimo kontaktus arba \u012f komutacinio skydelio vid\u0173 ir prispausti. I\u0161siki\u0161\u0119 laidai vienu veiksmu automati\u0161kai nupjaunami lygiai,<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5362 aligncenter\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss-300x161.jpg\" alt=\"\" width=\"515\" height=\"276\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss-300x161.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss-768x412.jpg 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss.jpg 800w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/><\/p>\n<p>Priklausomai nuo naudojamo standarto (EIA\/TIA 568A\/568B, IEC, REA arba DIN 47.100), svarbu u\u017etikrinti, kad a\u0161tuoni spalvotais kodais pa\u017eym\u0117ti atskiri kabelio laidai b\u016bt\u0173 teisingai priskirti a\u0161tuoniems spalvotiems jungties gnybtams. \u0160is standartas turi b\u016bti i\u0161laikytas visame \u012frenginyje, net ir atliekant modernizavim\u0105. Europoje pirmenyb\u0117 teikiama EIA\/TIA 568A kabeli\u0173 standartui.<\/p>\n<p>Tai, kuris standartas galiausiai bus naudojamas, yra elektri\u0161kai nesvarbu. Svarbu tik tai, kad visuose sujungimuose visada b\u016bt\u0173 naudojamas tas pats laid\u0173 kodavimas.<\/p>\n<p>Jei abu galai tokiu b\u016bdu sujungti tinkamai, tinklo testeriu patikrinamas laid\u0173 priskyrimas, trumpasis jungimas arba atsilaisvin\u0119s kontaktas. Bandymo ataskaita galiausiai lieka klientui.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Skaitymo laikas<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minut\u0117s<\/span><\/span>Tinklo technologijose vadinamasis komutacinis skydelis paprastai naudojamas didesniuose \u012frenginiuose. \u012evair\u016bs tinklo kabeliai, vedantys prie mar\u0161rutizatori\u0173, komutatori\u0173, ugniasieni\u0173 ir kit\u0173 tinklo komponent\u0173, prijungiami priekyje. Galin\u0117je dalyje i\u0161 grind\u0173, sienos ar lub\u0173 u\u017e tinklo spintos, kurioje sumontuoti tokie komutaciniai skydai, i\u0161vedami oran\u017ein\u0117s spalvos tinklo instaliacijos kabeliai. Tinklo instaliacijos kabeliai gali b\u016bti naudojami, pavyzd\u017eiui, su stand\u017eiu apvalkalu...&nbsp;<a href=\"https:\/\/csiag.eu\/lt\/blog\/2023\/10\/14\/netzwerktechnik-patchfeld\/\" rel=\"bookmark\">Skaityti daugiau \"<span class=\"screen-reader-text\">Tinklo technologija - Komutacinis skydelis<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"off","neve_meta_content_width":70,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2553],"tags":[2560,2561,1045,2558,2566,2562,2563,2564,2559,2556,2554,2555,2557,2565],"class_list":["post-5358","post","type-post","status-publish","format-standard","hentry","category-netzwerk-technik","tag-anschlussdose","tag-auflegeblock","tag-auflegewerkzeug","tag-biegeradius","tag-din-47100","tag-eia-tia-568a","tag-eia-tia-568b","tag-iec","tag-kabelkanal","tag-netzwerk-verlegekabel","tag-netzwerktechnik","tag-patchfeld","tag-patchkabel","tag-rea"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts\/5358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/comments?post=5358"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/posts\/5358\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/media?parent=5358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/categories?post=5358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/lt\/wp-json\/wp\/v2\/tags?post=5358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}