{"id":1912,"date":"2022-06-22T10:30:34","date_gmt":"2022-06-22T10:30:34","guid":{"rendered":"https:\/\/csiag.eu\/?p=1912"},"modified":"2025-10-24T18:05:27","modified_gmt":"2025-10-24T18:05:27","slug":"udens-sterilizacija-uv-c","status":"publish","type":"post","link":"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/","title":{"rendered":"\u016adens steriliz\u0101cija, izmantojot UV-C"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Satura r\u0101d\u012bt\u0101js<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Studien\" >P\u0113t\u012bjumi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Die_Theorie_%E2%80%A6\" >Teorija ...<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Strahlungs-Dosis\" >Starojuma deva<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#%E2%80%A6_und_die_Praxis\" >... un prakse<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Wahl_des_Einbauortes\" >Uzst\u0101d\u012b\u0161anas vietas izv\u0113le<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/#Besonderheit_Druckpumpe\" >\u012apa\u0161a funkcija spiediena s\u016bknis<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Las\u012b\u0161anas laiks<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">protokols<\/span><\/span>\n<p>\u016adens steriliz\u0101ciju var veikt da\u017e\u0101dos veidos. Visdro\u0161\u0101kais un vienk\u0101r\u0161\u0101kais risin\u0101jums ir apstaro\u0161ana ar UV-C starojumu (vi\u013c\u0146a garums 200 ... 280 nm). \u0160o metodi izmanto laboratorij\u0101s, kl\u012bnik\u0101s, r\u016bpniec\u012bb\u0101, akv\u0101rijos un m\u0101jsaimniec\u012bb\u0101s. Mikroorganismi, piem\u0113ram, bakt\u0113rijas, v\u012brusi, raugi un s\u0113n\u012btes, tiek izn\u012bcin\u0101ti 99,9 %, ja ir piem\u0113rots pl\u016bsmas \u0101trums laika vien\u012bb\u0101 un apstaro\u0161anas intensit\u0101te.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Studien\"><\/span>P\u0113t\u012bjumi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u016adens speci\u0101listu vid\u016b UV-C dzidrin\u0101\u0161ana da\u017ek\u0101rt ir ap\u0161aub\u0101mu diskusiju objekts attiec\u012bb\u0101 uz v\u012brusu inaktiv\u0101ciju. Arguments ir t\u0101ds, ka v\u012brusi ir maz\u0101ki par bakt\u0113rij\u0101m un UV-C tos neinaktiv\u0113.<\/p>\n\n\n\n<p>Port\u0101ls <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0043135424012211?via%3Dihub#bib0050\" target=\"_blank\" rel=\"noreferrer noopener\">P\u0113t\u012bjuma situ\u0101cija<\/a> Tom\u0113r tas apstiprina ar\u012b v\u012brusu inaktiv\u0101ciju, kas, protams, vienm\u0113r ir atkar\u012bga no devas lieluma.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Die_Theorie_%E2%80%A6\"><\/span>Teorija ...<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Tom\u0113r steriliz\u0101cija nav sinon\u012bms ar steriliz\u0101ciju. <a href=\"https:\/\/csiag.eu\/lv\/reversa-osmoze\/\" data-type=\"post\" data-id=\"2131\">Filtr\u0113\u0161ana<\/a>. Pies\u0101r\u0146ojo\u0161\u0101s da\u013ci\u0146as var no\u0146emt tikai ar atbilsto\u0161iem filtriem! Pies\u0101r\u0146ots \u016bdens ar\u012b samazina UV-C starojuma caurlaid\u012bbu un l\u012bdz ar to UV-C starojuma efektivit\u0101ti.<br>Piem\u0113ram, \u012bpa\u0161i t\u012bra \u016bdens 1 cm att\u0101lum\u0101 no starojuma avota (kas atbilst 80 % no 100 % starojuma jaudas, p\u0113c 17 mm v\u0113l 70 %) caurlaid\u012bba ir 99 ... 100 %, dzeram\u0101 \u016bdens 85 ... 98 %, lietus \u016bdens 75 ... 85 % un notek\u016bde\u0146i 50 ... 75 %.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Strahlungs-Dosis\"><\/span>Starojuma deva<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Starojuma devu apr\u0113\u0137ina p\u0113c laika (<em>t<\/em>) reizin\u0101ts ar intensit\u0101ti (<em>I<\/em>) un ir izteikts mJ\/cm.<sup>2<\/sup> izm\u0113r\u012bts.<\/p>\n\n\n\n<p>Mikroorganismu izn\u012bcin\u0101\u0161anai nepiecie\u0161am\u0101 deva ir, piem.<\/p>\n\n\n\n\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Patog\u0113ns<\/th><th class=\"column-2\">Deva mJ\/cm2<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Clostridium tetani<\/td><td class=\"column-2\">4,90<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">A hepat\u012bts<\/td><td class=\"column-2\">11,00<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Infekcioz\u0101 aizku\u0146\u0123a dziedzera nekroze<\/td><td class=\"column-2\">60,00 *<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Klebsiella pneumoniae<\/td><td class=\"column-2\">11,00<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Legionella pneumophilla<\/td><td class=\"column-2\">2,04<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Poliov\u012bruss<\/td><td class=\"column-2\">12,00<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Pseudomonas aeruginosa<\/td><td class=\"column-2\">11,00<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Rotav\u012bruss<\/td><td class=\"column-2\">35,00<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Saccharomyces cerevisiae<\/td><td class=\"column-2\">6,00<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Salmonella thyphi<\/td><td class=\"column-2\">14,00<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Salmonella thyphimurium<\/td><td class=\"column-2\">13,00<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Bac. subtilis sporas<\/td><td class=\"column-2\">12,00<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Staphylococcus aureus<\/td><td class=\"column-2\">36,00<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Streptococcus faecalis<\/td><td class=\"column-2\">4,50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n\n\n<p>Parasti ier\u012b\u010du dozas specifik\u0101cijas ir dotas J\/m.<sup>2<\/sup> vai mJ\/cm<sup>2<\/sup> nor\u0101d\u012bts. Tie attiecas uz attiec\u012bgo pl\u016bsmas \u0101trumu attiec\u012bb\u0101 uz nor\u0101d\u012bto vismaz 90% efektivit\u0101ti, kas nogalina bakt\u0113rijas un v\u012brusus.<\/p>\n\n\n\n<p>*V\u0113rt\u012bbas virs 40 mJ\/cm<sup>2<\/sup> ja pl\u016bsmas \u0101trums p\u0101rsniedz 4 ..., ir j\u0101izmanto otra l\u012bdzv\u0113rt\u012bga pak\u0101pe. 7 litri\/min., lai ticami noteiktu \u0161os patog\u0113nus, \u0146emot v\u0113r\u0101 iesp\u0113jamo fotol\u012b\u0101\u017eu fotoreaktiv\u0101ciju, ir j\u0101izmanto otra l\u012bdzv\u0113rt\u012bga pak\u0101pe. \u0160ie fermenti var labot UV-C gaismas izrais\u012btos \u0161\u016bnu DNS boj\u0101jumus. Lai efekt\u012bvi neitraliz\u0113tu \u0161o efektu, ir nepiecie\u0161amas aptuveni 44 mJ\/cm liel\u0101kas devas.<sup>2<\/sup>vai 440 J\/m<sup>2<\/sup> nepiecie\u0161ams.<\/p>\n\n\n\n<p>Ja pl\u016bsmas \u0101trumu samazina uz pusi, devas daudzums dubultojas, kas savuk\u0101rt palielina dezinfekcijas jaudu 10 reizes. 90 % dezinfekcija tad palielin\u0101s l\u012bdz 99 %. Ja devu tr\u012bsk\u0101r\u0161o, steriliz\u0101cija ir 99,9 %.<\/p>\n\n\n\n<p>Tas noz\u012bm\u0113, ka iepriek\u0161min\u0113t\u0101 fotoaktiv\u0101cija ar pusi pl\u016bsmas \u0101truma jau ir \u0146emta v\u0113r\u0101 ar vienu vien\u012bbu.<br>Tom\u0113r, ja pl\u0101nojat steriliz\u0113t \u013coti pies\u0101r\u0146otu \u016bdeni un ir nepiecie\u0161ams liel\u0101ks pl\u016bsmas \u0101trums, ieteicams izmantot otro un, iesp\u0113jams, tre\u0161o pak\u0101pi.<br><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"%E2%80%A6_und_die_Praxis\"><\/span>... un prakse<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Autofurgonos uzst\u0101d\u012btie spiediena s\u016bk\u0146i, piem. <a href=\"https:\/\/www.amazon.de\/Shurflo-Wasser-Camper-Liter-Armaturen\/dp\/B07DYS5XZJ\/ref=sr_1_1?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=22S8P4PJDEWEW&amp;keywords=shurflo+2095-204-112&amp;qid=1655889462&amp;sprefix=shurflo+2095-204-112%2Caps%2C123&amp;sr=8-1\" target=\"_blank\" rel=\"noreferrer noopener\">Shurflo<\/a>, nodro\u0161ina l\u012bdz 7 litriem min\u016bt\u0113. Viens <a href=\"https:\/\/www.purion.de\/produkte\/purion-500\/\" target=\"_blank\" rel=\"noreferrer noopener\">Purway 500<\/a> UV-C dezinfekcijas sist\u0113ma (12 vai 24 V l\u012bdzstr\u0101va) ir piem\u0113rota l\u012bdz 400 litriem\/h ar 400 J\/m.<sup>2<\/sup> un darbojas pie 254 nm vi\u013c\u0146u vi\u013c\u0146a ar UVT (<em>UV starojuma caurlaid\u012bba<\/em>) 90 %. Pl\u016bsmas \u0101trums ir 6,7 litri min\u016bt\u0113. Maz\u0101 cauru\u013cu \u0161\u0137\u0113rsgriezuma d\u0113\u013c, kas ir 10 ... 12 mm, Purway sist\u0113ma nodro\u0161ina maksim\u0101li 1,1 litru\/min. Tas dod 6 666,67 J\/m devu pie pl\u016bsmas \u0101truma aptuveni 60 litri stund\u0101.<sup>2<\/sup> un efektivit\u0101ti 99,999999999999 % (atbilst log12)!<\/p>\n\n\n\n<p>Ieteicams sist\u0113mu uzst\u0101d\u012bt ar t\u0101 saukto monitoringa ier\u012bci. Tas br\u012bdina, kad ir sasniegts lampas kalpo\u0161anas laiks, lai nodro\u0161in\u0101tu nemain\u012bgi augstu steriliz\u0101cijas jaudu.<br>J\u0101atz\u012bm\u0113, ka lampas dozas jauda laika gait\u0101 samazin\u0101s. T\u0101p\u0113c vai nu attiec\u012bgi j\u0101palielina kop\u0113j\u0101 dozas jauda, vai ar\u012b j\u0101pl\u0101no \u0101tr\u0101ks lampas nomai\u0146as interv\u0101ls.<br>Alternat\u012bvi var uzst\u0101d\u012bt darba stundu skait\u012bt\u0101ju, ja ir ieg\u0101d\u0101ta sist\u0113ma bez monitoringa bloka.<\/p>\n\n\n\n<p>Ieteicams pas\u016bt\u012bt ar\u012b rezerves UV-C lampu. Tas nav tik daudz saist\u012bts ar paredzamo kalpo\u0161anas laiku, bet dr\u012bz\u0101k ar to, ka saska\u0146\u0101 ar M\u0113rfija likumu past\u0101v liela varb\u016bt\u012bba, ka t\u0101 saboj\u0101sies priek\u0161laic\u012bgi visnepiem\u0113rot\u0101kaj\u0101 laik\u0101, t\u0101lu no attiec\u012bg\u0101s rezerves da\u013cas pieg\u0101d\u0101t\u0101ja...<br><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wahl_des_Einbauortes\"><\/span>Uzst\u0101d\u012b\u0161anas vietas izv\u0113le<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Du\u0161\u0101 vai vannas istab\u0101 nav nepiecie\u0161ams \u016bdens bez mikrobiem. Ta\u010du tas b\u016bs nepiecie\u0161ams virtuv\u0113. T\u0101p\u0113c ide\u0101li piem\u0113rots ir aukst\u0101 \u016bdens vads tie\u0161i pirms \u016bdens padeves vietas. Uz izlietnes skap\u012b\u0161a aizmugur\u0113j\u0101s sienas parasti ir pietiekami daudz vietas, lai 32 cm garo UV ier\u012bci integr\u0113tu \u016bdens \u0161\u013c\u016bten\u0113.<\/p>\n\n\n\n<p>Papildus diviem piem\u0113rotiem \u0161\u013c\u016btenes uzga\u013ciem ar \u0161\u013c\u016btenes skav\u0101m ir nepiecie\u0161ams ar\u012b 12\/24 V l\u012bdzstr\u0101vas piesl\u0113gums. \u0160eit noder \u016bdens s\u016bknis. Pietiek ar divdz\u012bslu kabeli, kas novietots gar \u016bdens \u0161\u013c\u016bten\u0113m s\u016bk\u0146a virzien\u0101 un tur paral\u0113li savienots ar t\u0101 baro\u0161anas avotu, ja s\u016bknis iesl\u0113dzas caur \u016bdens kr\u0101nu.<br><br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Besonderheit_Druckpumpe\"><\/span>\u012apa\u0161a funkcija spiediena s\u016bknis<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ja spiediena s\u016bk\u0146i darbojas ar p\u0101rtraukumiem, paral\u0113li j\u0101uzst\u0101da aiztures \u0137\u0113de, kas savuk\u0101rt p\u0101r\u0146em steriliz\u0101cijas sist\u0113mas baro\u0161anu, lai t\u0101 paliktu iesl\u0113gta regul\u0113jamu laika periodu pat p\u0113c spiediena s\u016bk\u0146a izsl\u0113g\u0161anas un \u016bdens ieguve turpin\u0101tos.<br><br>Tas tiek pan\u0101kts ar <a href=\"https:\/\/www.amazon.de\/dp\/B07W6NLTYT\/ref=pe_27091401_487024491_TE_item\" target=\"_blank\" rel=\"noreferrer noopener\">Vad\u012bbas elektronika<\/a>kas aizkav\u0113 steriliz\u0101cijas sist\u0113mas baro\u0161anas sprieguma izsl\u0113g\u0161anu uz regul\u0113jamu laika periodu.<br>Tas ir tie\u0161i savienots ar 12 vai 24 V borta spriegumu. Sign\u0101la ievadei kabelis ir savienots paral\u0113li spiediena s\u016bk\u0146a spiediena sl\u0113d\u017ea izejas plus vadam. Kad iesl\u0113dzas s\u016bknis, aktiviz\u0113tais pozit\u012bvais l\u012bmenis, iesl\u0113dzot spiediena s\u016bkni, iedarbina aiztures laiku un uztur dezinfekcijas sist\u0113mu iesl\u0113gtu uz iestat\u012bto laiku.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>p.s. Ja jums ir nepiecie\u0161ams person\u012bgs atbalsts, lai realiz\u0113tu pret samaksu, aicin\u0101m s\u016bt\u012bt.&nbsp;<a href=\"https:\/\/csiag.eu\/lv\/konsultaciju-pakalpojumi\/\">Rezerv\u0113\u0161ana<\/a>&nbsp;veikt!<\/p>\n<\/blockquote>\n\n\n\n<p><br><br><\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Las\u012b\u0161anas laiks<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">protokols<\/span><\/span>Wasser-Entkeimung kann auf verschiedenenArten erfolgen. Die sicherste und zugleich einfachste L\u00f6sung besteht in der Bestrahlung mit UV-C (Wellenl\u00e4nge 200 .. 280 nm). Diese Methode wird in Laboren, Kliniken, Industrie, Aquarien und Haushalten gleicherma\u00dfen eingesetzt. Mikroorganismen, wie z.B. Bakterien, Viren, Hefen, Pilze werden bei geeigneter Durchflussmenge je Zeiteinheit und Bestrahlungsintensit\u00e4t zu 99,9 % abget\u00f6tet. Studien Unter&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/lv\/blog\/2022\/06\/22\/wasser-entkeimung-uv-c\/\" rel=\"bookmark\">Las\u012bt vair\u0101k \"<span class=\"screen-reader-text\">\u016adens steriliz\u0101cija, izmantojot UV-C<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[340,338],"tags":[680,691,684,687,618,591,688,693,679,696,694,697,695,686,698,689,690,699,685,683,682,681,677,678,676,692],"class_list":["post-1912","post","type-post","status-publish","format-standard","hentry","category-wasser-entkeimung-mittels-uv-c","category-wasser-management","tag-bestrahlungsintensitaet","tag-dna","tag-dosis","tag-dosis-angaben","tag-druckpumpe","tag-durchflussmenge","tag-durchflussraten","tag-entkeimungs-kapazitaet","tag-filterung","tag-filterwechsel","tag-fliessgeschwindigkeit","tag-kalk","tag-lampenlebensdauer","tag-mikroorganismen","tag-pha","tag-photolyasen","tag-photoreaktivierung","tag-polyphosphat","tag-strahlungs-dosis","tag-strahlungsleistung","tag-strahlungsquelle","tag-transmission","tag-uv-c","tag-v-c-klaerer","tag-wasser-entkeimung","tag-zellschaden"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/posts\/1912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/comments?post=1912"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/posts\/1912\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/media?parent=1912"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/categories?post=1912"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/tags?post=1912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}