{"id":6792,"date":"2024-03-01T16:15:43","date_gmt":"2024-03-01T16:15:43","guid":{"rendered":"https:\/\/csiag.eu\/?p=6792"},"modified":"2024-12-29T14:43:16","modified_gmt":"2024-12-29T14:43:16","slug":"teltonika-rutx50-failover-slodzes-balansesana","status":"publish","type":"post","link":"https:\/\/csiag.eu\/lv\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/","title":{"rendered":"Teltonika RUTX50 - Failover \/ slodzes balans\u0113\u0161ana"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Satura r\u0101d\u012bt\u0101js<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/lv\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Failover_Konfiguration\" >P\u0101rsl\u0113g\u0161an\u0101s konfigur\u0101cija<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/lv\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Interface_configuration\" >Interfeisa konfigur\u0101cija<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/lv\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Rule\" >Noteikums<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/lv\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/#Loadbalancing_Konfiguration\" >Slodzes balans\u0113\u0161anas konfigur\u0101cija<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Las\u012b\u0161anas laiks<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">protokols<\/span><\/span>\n<p>Da\u017ei Teltonika mar\u0161rut\u0113t\u0101ji, tostarp RUTX50, nodro\u0161ina \u0161\u0101das funkcijas. <em>Failover<\/em> un <em>Slodzes l\u012bdzsvaro\u0161ana<\/em> pieejams.<\/p>\n\n\n\n<p><em>Failover<\/em> pied\u0101v\u0101 iesp\u0113ju p\u0101rsl\u0113gties uz citu savienojuma veidu, ja viens savienojuma veids nedarbojas, piem\u0113ram, no WLAN piek\u013cuves punkta uz mobilajiem datiem vai no WAN (piem\u0113ram, Starlink) uz mobilajiem datiem, iesp\u0113jama pat autom\u0101tiska p\u0101rsl\u0113g\u0161an\u0101s starp visiem nosac\u012bjumiem.<\/p>\n\n\n\n<p><em>Slodzes l\u012bdzsvaro\u0161ana<\/em> tiek izmantots, lai palielin\u0101tu joslas platumu, piem\u0113ram, paral\u0113li izmantojot WAN un WLAN vai LTE, abus joslas platumus kop\u0101. Tom\u0113r tas neattiecas uz VIENU savienojumu, VIENU klientu.<br>Ja, piem\u0113ram, lejupiel\u0101di inici\u0113 klients A, slodzes l\u012bdzsvaro\u0161ana nepalielin\u0101s lejupiel\u0101des \u0101trumu. Tom\u0113r, ja, piem\u0113ram, cits klients B s\u0101k Zoom san\u0101ksmi, t\u0101 tiek apstr\u0101d\u0101ta, izmantojot otru kan\u0101lu, un klienta A notieko\u0161\u0101 lejupiel\u0101de netiek pal\u0113nin\u0101ta.<\/p>\n\n\n\n<p><em>Failover<\/em> un <em>Slodzes l\u012bdzsvaro\u0161ana<\/em> var izmantot tikai ekskluz\u012bvi, t. i., tos nevar izmantot vienlaic\u012bgi, pat ja konfigur\u0101cijas lap\u0101 nor\u0101d\u012bts cit\u0101di.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Failover_Konfiguration\"><\/span>P\u0101rsl\u0113g\u0161an\u0101s konfigur\u0101cija<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Lai aktiviz\u0113tu <em>Failover<\/em>-funkcija, ir j\u0101aktiviz\u0113 tikai attiec\u012bg\u0101s saskarnes, iestatot attiec\u012bgos sl\u0113d\u017eus uz \"iesl\u0113gts\".<br>\u0160aj\u0101 piem\u0113r\u0101 visizplat\u012bt\u0101kais variants: WAN pirmaj\u0101 viet\u0101 un LTE otraj\u0101 viet\u0101. P\u0113c noklus\u0113juma datpl\u016bsma tiek mar\u0161rut\u0113ta, izmantojot WAN. Ja WAN nedarbojas, autom\u0101tiski tiek aktiviz\u0113ts LTE; ja WAN atgrie\u017eas, LTE tiek deaktiviz\u0113ts un tiek aktiviz\u0113ts WAN.<\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"349\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-1024x349.png\" alt=\"\" class=\"wp-image-7004\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-1024x349.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-1536x524.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-2048x698.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-18x6.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-300x102.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-9-768x262.png 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">T\u012bkls - Failover<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Zem <em>Mode<\/em> funkcijas iestat\u012bjumu <em>Failover<\/em> VAI <em>Slodzes l\u012bdzsvaro\u0161ana<\/em>.<\/p>\n\n\n\n<p>Konkr\u0113tas specifik\u0101cijas, kad av\u0101rijas p\u0101rsl\u0113g\u0161anai j\u0101k\u013c\u016bst akt\u012bvai, tiek iestat\u012btas, noklik\u0161\u0137inot uz <em>Redi\u0123\u0113t<\/em> defin\u0113ts.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"619\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-1024x619.png\" alt=\"\" class=\"wp-image-8496\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-1024x619.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-18x12.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-300x181.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11-768x464.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-11.png 1174w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Interface_configuration\"><\/span>Interfeisa konfigur\u0101cija<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Zem <em>Interfeisa konfigur\u0101cija<\/em> piem\u0113ram, \u0161eit ir nor\u0101d\u012bts, ka visi <em>3<\/em> sekundes (<kbd>Intervals<\/kbd>) ir j\u0101veic tests, kuram ir piem\u0113rojams \u0161\u0101ds noteikums (<em>Noteikums<\/em>) nosaka, ka ping uz IP adresi (<kbd>IP izseko\u0161ana<\/kbd>) <em>8.8.8.8 <\/em>tiek izpild\u012bts. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rule\"><\/span>Noteikums<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>V\u0113rt\u012bba <em>1<\/em> (<kbd>Uzticam\u012bba<\/kbd>) pie\u0146em, ka tie\u0161i viens resursdators ir pie\u0161\u0137irts tie\u0161i vienam (<kbd>Count<\/kbd>) Ping nesniedz atbildi. Vai \u0161is <em>3<\/em>-subjekts (<kbd>Uz aug\u0161u \/ uz leju<\/kbd>), tad tiek pie\u0146emts, ka savienojums ir atvienots un t\u0101d\u0113j\u0101di s\u0101kotn\u0113ji defin\u0113tais <em>Interfeisa konfigur\u0101cija<\/em> <kbd>Flush savienojums<\/kbd> \u201e<em>Atvienots<\/em>\" un p\u0101rsl\u0113dzas uz mobilo datu savienojumu. Tom\u0113r, ja ping ir veiksm\u012bgs 3 reizes (<kbd>Uz aug\u0161u<\/kbd>), paliek <em>WAN<\/em> <em>tie\u0161saist\u0113<\/em> un <em>mob1s1a1<\/em> <em>gaid\u012b\u0161anas re\u017e\u012bm\u0101<\/em>.<\/p>\n\n\n\n<p>Noklik\u0161\u0137inot uz pogas <em>Saglab\u0101t un piem\u0113rot<\/em> (<em>Saglab\u0101t un piem\u0113rot<\/em>), izmai\u0146as tiek saglab\u0101tas un st\u0101jas sp\u0113k\u0101.<\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Loadbalancing_Konfiguration\"><\/span>Slodzes balans\u0113\u0161anas konfigur\u0101cija<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u012apa\u0161a uzman\u012bba tiek piev\u0113rsta parametram \"Ratio\". Tas nosaka, k\u0101du da\u013cu no datpl\u016bsmas p\u0101r\u0146em attiec\u012bgais interfeiss.<\/p>\n\n\n\n<p>Piem\u0113ram, ja attiec\u012bba ir 1 un 1 (= 2), puse datpl\u016bsmas tiek sadal\u012bta uz 1. saskarni (WAN) un puse uz 2. saskarni (LTE). Ja attiec\u012bba ir 9 (WAN) un 1 (LTE) (= 10), tad WAN izmantojums ir 90 % (devi\u0146as desmit\u0101s da\u013cas) un LTE izmantojums ir 10 % (viena desmit\u0101 da\u013ca).<\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"243\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-1024x243.png\" alt=\"\" class=\"wp-image-7003\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-1024x243.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-1536x364.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-2048x485.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-18x4.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-300x71.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/image-8-768x182.png 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">T\u012bkls - slodzes balans\u0113\u0161ana<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u0160eit saska\u0146\u0101 ar <em>Mode<\/em> funkcija <em>Slodzes l\u012bdzsvaro\u0161ana<\/em> iev\u0113l\u0113ts.<\/p>\n\n\n\n<p>Noklik\u0161\u0137inot uz pogas <em>Saglab\u0101t un piem\u0113rot<\/em> (<em>Saglab\u0101t un piem\u0113rot<\/em>), izmai\u0146as tiek saglab\u0101tas un st\u0101jas sp\u0113k\u0101.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Las\u012b\u0161anas laiks<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">protokols<\/span><\/span>Da\u017ei Teltonika mar\u0161rut\u0113t\u0101ji, tostarp RUTX50, nodro\u0161ina k\u013c\u016bmju p\u0101rsl\u0113g\u0161anas un slodzes balans\u0113\u0161anas funkcijas. Failover pied\u0101v\u0101 iesp\u0113ju p\u0101rsl\u0113gties uz citu savienojuma veidu, ja viens savienojuma veids nedarbojas, piem\u0113ram, no WLAN piek\u013cuves punkta uz mobilajiem datiem vai no WAN (piem\u0113ram, Starlink) uz mobilajiem datiem, iesp\u0113jama pat autom\u0101tiska p\u0101rsl\u0113g\u0161an\u0101s starp visiem nosac\u012bjumiem. Slodzes l\u012bdzsvaro\u0161ana...&nbsp;<a href=\"https:\/\/csiag.eu\/lv\/blog\/2024\/03\/01\/teltonika-rutx50-failover-loadbalancing\/\" rel=\"bookmark\">Las\u012bt vair\u0101k \"<span class=\"screen-reader-text\">Teltonika RUTX50 - Failover \/ slodzes balans\u0113\u0161ana<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"no","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[3192,3191,2553,2868],"tags":[2604,2042,3833,3838,3835,2873,3837,3836,3830,573,3193,725,3839,3196,2793,3195,3832,574,2683,2682,3831,3194,3834,3170,3178,563],"class_list":["post-6792","post","type-post","status-publish","format-standard","hentry","category-failover","category-loadbalancing","category-netzwerk-technik","category-router","tag-ausfall","tag-client","tag-count","tag-disconnected","tag-down","tag-failover","tag-flush-connection-on","tag-interface-configuration","tag-interval","tag-konfiguration","tag-loadbalancing","tag-lte","tag-mob1s1a1","tag-mode","tag-ping","tag-ratio","tag-reliability","tag-router","tag-rutx50","tag-teltonika","tag-track-ip","tag-traffic","tag-up","tag-wan","tag-wifi","tag-wlan"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/posts\/6792","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/comments?post=6792"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/posts\/6792\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/media?parent=6792"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/categories?post=6792"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/lv\/wp-json\/wp\/v2\/tags?post=6792"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}