{"id":11434,"date":"2025-10-07T17:09:47","date_gmt":"2025-10-07T17:09:47","guid":{"rendered":"https:\/\/csiag.eu\/?p=11434"},"modified":"2025-10-07T17:54:09","modified_gmt":"2025-10-07T17:54:09","slug":"redesign-underdistribusjon","status":"publish","type":"post","link":"https:\/\/csiag.eu\/nb\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/","title":{"rendered":"Ny utforming av underfordelingstavlen"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Innholdsfortegnelse<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/nb\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Durchgangsklemmen-Installationskasten\" >Installasjonsboks for gjennomf\u00f8ringsklemme<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/nb\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Verteilerschrank\" >Distribusjonsskap<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/nb\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/#Leistungsmessung\" >Effektm\u00e5ling<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesetid<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>\n<p class=\"wp-block-paragraph\">Det kan v\u00e6re fornuftig \u00e5 bygge om en underfordelingstavle i huset i flere tilfeller: for eksempel n\u00e5r man skal fornye hele det elektriske anlegget eller bytte ut et gammelt sikringssystem med et nytt, eventuelt med jordfeilbryter(e).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Durchgangsklemmen-Installationskasten\"><\/span>Installasjonsboks for gjennomf\u00f8ringsklemme<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">I begge tilfeller viser det seg at de gamle kablene er for korte, og derfor forkortes de til en standardisert passende lengde og gj\u00f8res tilgjengelige for videresending til nedstr\u00f8ms samleskinner og automatiske maskiner osv. ved hjelp av for eksempel PHOENIX-CONTACT UT 2,5 BU-gjennomf\u00f8ringsklemmer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis h\u00f8yere kapasitet enn for 2,5 mm<sup>2<\/sup>Hvis 2,5 mm gjennomf\u00f8ringsklemmer m\u00e5 brukes til kablingen, m\u00e5 de brukes i stedet for 2,5 mm gjennomf\u00f8ringsklemmer. Kablingen m\u00e5 ogs\u00e5 v\u00e6re utformet for de n\u00f8dvendige tverrsnittene.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"900\" height=\"511\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_.png\" alt=\"\" class=\"wp-image-11436\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_.png 900w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-300x170.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-768x436.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Durchgangsklemmen_-18x10.png 18w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Installasjon i en separat, bred 1-rads fordelingstavle anbefales hvis den nye fordelingstavlen er smalere enn den forrige.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verteilerschrank\"><\/span>Distribusjonsskap<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">St\u00f8rrelsen p\u00e5 fordelingsskapet avhenger av hvilke tilleggskomponenter som skal installeres. I 3-fase systemer b\u00f8r det ha 4 rader.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den f\u00f8rste raden brukes til den 5-polede hovedledningsavgreningsklemmen (de tre fasene, n\u00f8ytral- og jordlederen), den 3-polede hovedbryteren (for de tre fasene) og den 4-polede jordfeilbryteren (for n\u00f8ytrallederen og de tre fasene). De f\u00f8lgende tre radene er tilordnet de tre fasene og utstyrt med passende effektbrytere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Normalt kommer alle kabler inn ovenfra. I noen installasjonssituasjoner kan kablene ogs\u00e5 komme inn i fordelingsboksen nedenfra.<br>For \u00e5 unng\u00e5 \u00e5 m\u00e5tte trekke alle kablene bak automatradene opp til \u00f8verste etasje (noe som vanligvis er vanskelig p\u00e5 grunn av den begrensede plassen bak DIN-skinnene), finnes det ogs\u00e5 her gjennomf\u00f8ringsklemmer i enden av de tre siste radene, der kablene enkelt kan f\u00f8res oppover langs kanten.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"510\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-510x1024.png\" alt=\"\" class=\"wp-image-11437\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-510x1024.png 510w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-149x300.png 149w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler-6x12.png 6w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteiler.png 600w\" sizes=\"(max-width: 510px) 100vw, 510px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Og den ferdige distribusjonen ...<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"433\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-433x1024.png\" alt=\"\" class=\"wp-image-11448\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-433x1024.png 433w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-127x300.png 127w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl-5x12.png 5w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/Verteilung_kpl.png 600w\" sizes=\"(max-width: 433px) 100vw, 433px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leistungsmessung\"><\/span>Effektm\u00e5ling<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis du ikke bare vil lese av totalforbruket ditt p\u00e5 m\u00e5leren, men ogs\u00e5 \u00f8nsker \u00e5 finne ut av forbruket ditt i faser, kan du bruke ulike enheter som dekker et bredt spekter av bruksomr\u00e5der og som enkelt viser data via en app.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bruken av slike innretninger er imidlertid ikke bare for oversiktlighetens skyld, men s\u00e6rlig for \u00e5 sikre en noenlunde jevn utnyttelse av de enkelte fasene.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis du \u00f8nsker \u00e5 behandle dataene videre eller for eksempel bytte forbrukere, for eksempel ladeprosessen til et kj\u00f8ret\u00f8y, p\u00e5 bestemte tidspunkter og avhengig av den faserelaterte bruken, b\u00f8r du s\u00f8rge for at enheten ogs\u00e5 kan integreres i slike SmartHomes og at den n\u00f8dvendige protokollen st\u00f8ttes, for eksempel Shelly-produkter.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"712\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1024x712.png\" alt=\"\" class=\"wp-image-11438\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1024x712.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-300x208.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-768x534.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1536x1067.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-2048x1423.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-18x12.png 18w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Denne enheten er tilgjengelig i to versjoner: \"T\" st\u00e5r for terminaltilkoblinger som er beregnet for direkte montering p\u00e5 en jordfeilbryter. \"W\"-varianten har i stedet en kabel med en kabelsko for hver stikkontakt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Begge registrerer forbruk og innmating p\u00e5 samme m\u00e5te via induktive sensorer i et hus som er utformet i samme nettdimensjon som jordfeilbrytere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Under installasjonen m\u00e5 str\u00f8mretningen overholdes for ikke \u00e5 registrere avkastninger som egentlig skal allokeres til forbrukssiden ... - F\u00f8lgelig indikerer \"L\" forbrukssiden, \"K\" tilf\u00f8rsels- \/ innmatingssiden (PV).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hver fase er koblet til de tre pluggkontaktene via tre kabelsko, og n\u00f8ytrallederen er ogs\u00e5 tilkoblet.<br>Fasene skal beskyttes med hurtigvirkende 100 mA 20\u00d75 mm glasssikringer i egnede sikringsholdere. Det sies at det har hendt at en slik enhet stille og rolig har g\u00e5tt opp i flammer ...<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det er enkelt \u00e5 sette opp enheten. Ved hjelp av appen, som kan lastes ned via QR-kode fra den aktuelle appbutikken, kobler du deg til enheten via Bluetooth, som gjenkjennes umiddelbart. Deretter tilbys en tilkobling til det lokale WLAN. N\u00e5r de relevante sikkerhetssp\u00f8rsm\u00e5lene er godkjent, kobles enheten til Wi-Fi-hjemmenettverket og kan brukes fra da av.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Visningen av forbruksdata i appen er oversiktlig, om enn ikke spektakul\u00e6rt designet.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"989\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1024x989.png\" alt=\"\" class=\"wp-image-11439\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1024x989.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-300x290.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-768x742.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-1536x1484.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-2048x1979.png 2048w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/10\/image-1-12x12.png 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-text-align-center wp-block-paragraph\">All informasjon uten garanti - installasjoner p\u00e5 elektriske anlegg m\u00e5 kun utf\u00f8res av autorisert fagpersonell!<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesetid<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutter<\/span><\/span>Eine Unterverteilung im Haus neu zu gestalten kann im verschiedenen F\u00e4llen sinnvoll sein: so z.B. bei einer vollst\u00e4ndigen Erneuerung der elektrischen Verkabelung oder auch, um eine alte Sicherungsanlage durch eine neue ggf. mit FI-Schalter(n) zu ersetzen. Durchgangsklemmen-Installationskasten In beiden F\u00e4llen erweisen sich die alten Kabel als zu kurz, weshalb man diese auf eine einheitlich passende&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/nb\/blog\/2025\/10\/07\/unterverteilung-neu-gestalten\/\" rel=\"bookmark\">Les mer \"<span class=\"screen-reader-text\">Ny utforming av underfordelingstavlen<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1],"tags":[5494,551,5488,5490,5489,5486,5485,5484,5497,813,5482,5493,5088,389,5487,812,5498,5495,5496,1062,981,370,5481,3388,2621,2536,5483,563],"class_list":["post-11434","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-auslastung","tag-bt","tag-durchgangsklemmen","tag-einspeisedaten","tag-einspeisung","tag-fehlerstromschutzschalter","tag-fi-schalter-2","tag-galssicherung","tag-hauptleitungs-abzweigklemme","tag-installation","tag-installationskasten","tag-ladevorgang","tag-last","tag-leistungsmessung","tag-phoenix-contact","tag-photovoltaik","tag-pv","tag-shelly","tag-shelly-gen3","tag-sicherung","tag-sicherungsautomat","tag-smarthome","tag-unterverteilung","tag-verbrauch","tag-verbrauchsdaten","tag-verteiler","tag-verteilerschrank","tag-wlan"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/posts\/11434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/comments?post=11434"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/posts\/11434\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/media?parent=11434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/categories?post=11434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/tags?post=11434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}