{"id":3823,"date":"2023-03-28T06:02:51","date_gmt":"2023-03-28T06:02:51","guid":{"rendered":"https:\/\/csiag.eu\/?p=3823"},"modified":"2023-03-28T06:05:13","modified_gmt":"2023-03-28T06:05:13","slug":"victron-multiplus-ii-inverter-overbelastning","status":"publish","type":"post","link":"https:\/\/csiag.eu\/nb\/blog\/2023\/03\/28\/victron-multiplus-ii-inverter-overload\/","title":{"rendered":"Victron - Multiplus II - Overbelastning av vekselretter?"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesetid<\/span> <span class=\"rt-time\"> &lt; 1<\/span> <span class=\"rt-label rt-postfix\">Minutt<\/span><\/span>\n<p class=\"wp-block-paragraph\">Victron Multiplus II kj\u00f8rte perfekt hele tiden. Plutselig viser den \"Overload\" og sl\u00e5r seg av, for s\u00e5 \u00e5 sl\u00e5 seg p\u00e5 igjen umiddelbart etterp\u00e5 - og etter en stund begynner den \u00e5 spille det samme spillet igjen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Overbelastning? For mye belastning? En titt p\u00e5 <em>Victron Cerbo GX ber\u00f8ringspanel<\/em> viser bare rundt 300 W AC-belastning. S\u00e5 hvorfor er det en overbelastning? Omtrent 80 W kommer inn via PV, s\u00e5 ingen reell overbelastning heller.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hvis du observerer omstendighetene n\u00e6rmere, vil du legge merke til at feilen alltid oppst\u00e5r n\u00e5r solen skinner med full styrke. S\u00e5 hva har solen med overbelastning \u00e5 gj\u00f8re?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e5, <em>Victron Cerbo GX<\/em> og de tilkoblede enhetene styrer hverandre p\u00e5 en intelligent m\u00e5te. Noen ganger mer intelligent enn brukeren ...<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For n\u00e5r batteriene er fulle og solcellene leverer str\u00f8m, vet ikke Multiplus hva den skal gj\u00f8re med overskuddsstr\u00f8mmen og f\u00f8ler seg derfor \"overbelastet\" med oppgaven. Betyr dette at solcellemodulene m\u00e5 sl\u00e5s av? Nei, fordi kontrollsystemet til Multiplus <em>Victron Cerbo GX<\/em> mye bedre. Du m\u00e5 imidlertid fortelle den i innstillingene at den ogs\u00e5 har en DC-kilde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00e5 videre <em>Victron Cerbo GX ber\u00f8ringspanel<\/em> \u00e5pne menyen, skriv inn <em>Innstillinger<\/em> og i <em>Systemoppsett<\/em> aktiverer du alternativet \"Har DC\".<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tilbake i sidevisningen har det n\u00e5 dukket opp et ekstra informasjonsfelt for \"DC Power\" nederst i midten mellom symbolet for batteriet og MPPT-kontrolleren.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e5 har til og med <em>Victron Multiplus II<\/em>at det i tillegg til ladetjenestene er andre ivrige hjelpere involvert i batteriladeprosessen. Og se: Den viser ikke lenger noen \"overbelastning\", og kan n\u00e5 helt avslappet konsentrere seg om sine egne oppgaver igjen.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Lesetid<\/span> <span class=\"rt-time\"> &lt; 1<\/span> <span class=\"rt-label rt-postfix\">Minutt<\/span><\/span>Die ganze Zeit lief der Victron Multiplus II einwandfrei. Pl\u00f6tzlich zeigt er &#8222;Overload&#8220; an und schaltet ab, um gleich darauf wieder einzuschalten &#8211; und, nach einer Weile, wieder das selbe Spiel zu treiben. Overload? Zu viel Last? Ein Blick auf das Victron Cerbo GX Touch Panel zeigt lediglich rund 300 W AC Last an. Weshalb&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/nb\/blog\/2023\/03\/28\/victron-multiplus-ii-inverter-overload\/\" rel=\"bookmark\">Les mer \"<span class=\"screen-reader-text\">Victron - Multiplus II - Overbelastning av vekselretter?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[317,344],"tags":[521,1301,1297,1298,528,1289,1299,1300,519],"class_list":["post-3823","post","type-post","status-publish","format-standard","hentry","category-autarkie-im-wohnwagen-wohnmobil","category-victron-systemloesung","tag-cerbo-gx","tag-dc-power","tag-dc-quelle","tag-has-dc","tag-mppt-regler","tag-multiplus-ii-2","tag-overload","tag-ueberlast","tag-victron"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/posts\/3823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/comments?post=3823"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/posts\/3823\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/media?parent=3823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/categories?post=3823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/nb\/wp-json\/wp\/v2\/tags?post=3823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}