{"id":10071,"date":"2025-06-17T10:30:00","date_gmt":"2025-06-17T10:30:00","guid":{"rendered":"https:\/\/csiag.eu\/?p=10071"},"modified":"2025-06-18T15:46:20","modified_gmt":"2025-06-18T15:46:20","slug":"porque-e-que-sao-necessarios-reles","status":"publish","type":"post","link":"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/","title":{"rendered":"Porque \u00e9 que precisa de rel\u00e9s?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Kabelquerschnitt\" >Se\u00e7\u00e3o transversal do cabo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Relais-Arten\" >Tipos de rel\u00e9s<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Schlieser-_Offner\" >Contacto normalmente aberto \/ normalmente fechado<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Wechsler\" >Mudan\u00e7a<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Sonderrelais\" >Rel\u00e9 especial<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/#Praxis-Beispiel\" >Exemplo pr\u00e1tico<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p>Os rel\u00e9s s\u00e3o utilizados para comutar consumidores (cargas) de maior pot\u00eancia (W - Watt - <em>P<\/em>) do que o contacto de comuta\u00e7\u00e3o do interrutor ou a sec\u00e7\u00e3o transversal do cabo no interrutor permitiriam.<\/p>\n\n\n\n<p>Toda a gente conhece o clique r\u00edtmico do rel\u00e9 indicador no seu autom\u00f3vel. Um sistema eletr\u00f3nico integrado assegura o intervalo de intermit\u00eancia legalmente prescrito e liga e desliga o rel\u00e9. As luzes indicadoras ligadas ao rel\u00e9 e alimentadas com tens\u00e3o atrav\u00e9s do rel\u00e9 piscam ao mesmo ritmo.<\/p>\n\n\n\n<p>Agora, os indicadores n\u00e3o precisam de muita energia, n\u00e3o t\u00eam correntes elevadas, mas \u00e9 uma hist\u00f3ria completamente diferente com as l\u00e2mpadas de condu\u00e7\u00e3o!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Kabelquerschnitt\"><\/span>Se\u00e7\u00e3o transversal do cabo<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Em \u00faltima an\u00e1lise, mesmo os mais pequenos <a href=\"https:\/\/csiag.eu\/pt\/a-instalacao-electrica-de-uma-autocaravana-nao-e-bruxaria\/#Kabelquerschnitt\" data-type=\"post\" data-id=\"6364\" target=\"_blank\" rel=\"noreferrer noopener\">Se\u00e7\u00f5es transversais do cabo<\/a> (aqui, as sec\u00e7\u00f5es transversais do cabo na gama de tens\u00e3o DC podem ser determinadas) entre o interrutor e o rel\u00e9, o que reduz os custos e beneficia as sec\u00e7\u00f5es transversais maiores do rel\u00e9 para a carga. Estes cabos podem ser mantidos curtos, o que, por sua vez, mant\u00e9m baixos os custos e as quedas de tens\u00e3o no trajeto do cabo.<\/p>\n\n\n\n<p>Se os cabos forem demasiado finos para a pot\u00eancia necess\u00e1ria, aquecem e podem tornar-se um fio de aquecimento. Os cabos finos t\u00eam uma resist\u00eancia \u00f3hmica elevada (resist\u00eancia \u03a9 (Ohm) - <em>R<\/em>), o que leva a uma menor tens\u00e3o no final do que no in\u00edcio.<br>Um enrolador de cabo com 50 m e uma sec\u00e7\u00e3o transversal de cabo de 3 x 1,5 mm<sup>2<\/sup> alimenta uma carga com 16 amperes (A - amperagem <em>EU<\/em>) continua a ser apenas 210 volts (V - tens\u00e3o - <em>U<\/em>). Se utilizar um cabo com 3x 2,5 mm em vez de<sup>2<\/sup>ainda est\u00e1 a 221 V.<\/p>\n\n\n\n<p>Os campistas s\u00e3o frequentemente confrontados com este problema, levando consigo longas bobinas de cabos e queixando-se mais tarde do elevado consumo de energia ou da resposta dos disjuntores, quando em casa tudo funcionava bem - com um cabo curto...!<br>Isto deve-se ao facto de uma carga consumir mais corrente se receber uma tens\u00e3o demasiado baixa para fornecer a sua pot\u00eancia. Por conseguinte, o consumo de energia \u00e9 mais elevado quando a tens\u00e3o \u00e9 inferior \u00e0 \"normal\".<\/p>\n\n\n\n<p>As sec\u00e7\u00f5es transversais dos cabos na gama de tens\u00e3o CA - CA - podem ser utilizadas neste <a href=\"https:\/\/csiag.eu\/pt\/o-que-fazer-em-caso-de-falha-de-energia\/#Kabelquerschnitt_AC\" data-type=\"post\" data-id=\"1418\" target=\"_blank\" rel=\"noreferrer noopener\">Tabela<\/a> ser calculado.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Relais-Arten\"><\/span>Tipos de rel\u00e9s<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Na constru\u00e7\u00e3o de ve\u00edculos, existem normalmente rel\u00e9s operados com tens\u00e3o cont\u00ednua (DC) de 12 ou 24 V que podem comutar cargas at\u00e9 cerca de 30 A. Os rel\u00e9s de pot\u00eancia tamb\u00e9m podem suportar at\u00e9 400 A.<\/p>\n\n\n\n<p>As conex\u00f5es das bobinas do rel\u00e9 s\u00e3o identificadas como 85 e 86. Para rel\u00e9s com um diodo supressor de fa\u00edscas embutido, 86 \u00e9 atribu\u00eddo a mais. Rel\u00e9s sem diodo supressor de fa\u00edscas podem ser conectados com qualquer polaridade, mas provou ser uma boa id\u00e9ia selecionar a polaridade como se um diodo supressor de fa\u00edscas tivesse sido instalado (em eletr\u00f4nica isso \u00e9 chamado de <em>D\u00edodo de roda livre<\/em>). Desta forma, um rel\u00e9 de qualquer configura\u00e7\u00e3o pode ser utilizado na mesma tomada de liga\u00e7\u00e3o sem ser danificado por uma polaridade incorrecta. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Schlieser-_Offner\"><\/span>Contacto normalmente aberto \/ normalmente fechado<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Os rel\u00e9s para ligar uma carga t\u00eam um contacto NA, ou um contacto NF para a desligar. O contacto de um rel\u00e9 normalmente aberto est\u00e1, portanto, aberto no estado desenergizado e fecha assim que o rel\u00e9 \u00e9 alimentado com tens\u00e3o. O contacto NF actua no sentido inverso.<\/p>\n\n\n\n<p>Os contactos de comuta\u00e7\u00e3o est\u00e3o identificados com 30 (mais) e 87 (consumidor).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"587\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-587x1024.png\" alt=\"\" class=\"wp-image-10072\" style=\"width:159px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-587x1024.png 587w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-172x300.png 172w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5-7x12.png 7w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-5.png 659w\" sizes=\"(max-width: 587px) 100vw, 587px\" \/><\/figure>\n<\/div>\n\n\n<p>O diodo de extin\u00e7\u00e3o de fa\u00edscas sob a bobina do rel\u00e9 tem a tarefa de absorver e compensar os picos de tens\u00e3o de v\u00e1rias centenas de volts que ocorrem na bobina quando a fonte de alimenta\u00e7\u00e3o do rel\u00e9 \u00e9 desligada.<br>Mesmo que a maioria dos rel\u00e9s utilizados na engenharia autom\u00f3vel n\u00e3o tenha um circuito de prote\u00e7\u00e3o integrado, porque as bobinas dos rel\u00e9s s\u00e3o bastante \"robustas\", \u00e9 mais sensato utilizar rel\u00e9s com um d\u00edodo de supress\u00e3o de fa\u00edscas integrado, se poss\u00edvel!<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wechsler\"><\/span>Mudan\u00e7a<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>O rel\u00e9 de comuta\u00e7\u00e3o permite a comuta\u00e7\u00e3o de duas cargas e, portanto, tem tr\u00eas contactos de comuta\u00e7\u00e3o e, portanto, tamb\u00e9m tr\u00eas liga\u00e7\u00f5es, 30 (positivo), 87 (NO) e 87a (NC).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"504\" height=\"954\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6.png\" alt=\"\" class=\"wp-image-10073\" style=\"width:161px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6.png 504w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6-158x300.png 158w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-6-6x12.png 6w\" sizes=\"(max-width: 504px) 100vw, 504px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sonderrelais\"><\/span>Rel\u00e9 especial<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Estes incluem rel\u00e9s de pisca-pisca ou temporizadores com eletr\u00f3nica integrada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Praxis-Beispiel\"><\/span>Exemplo pr\u00e1tico<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>O objetivo \u00e9 poder ligar e desligar v\u00e1rias cargas de forma centralizada atrav\u00e9s de um painel de interruptores. <\/p>\n\n\n\n<p>Os retalhistas oferecem uma grande variedade de produtos, todos eles com uma coisa em comum: os cabos s\u00e3o muito finos e apenas concebidos para correntes baixas. Recordamos: o cobre \u00e9 caro ...<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"570\" height=\"299\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8.png\" alt=\"\" class=\"wp-image-10075\" style=\"width:466px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8.png 570w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8-300x157.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-8-18x9.png 18w\" sizes=\"(max-width: 570px) 100vw, 570px\" \/><\/figure>\n<\/div>\n\n\n<p>O que come\u00e7a com uma pequena l\u00e2mpada LED transforma-se num sistema de ilumina\u00e7\u00e3o completo mais rapidamente do que o esperado. Isso tamb\u00e9m aumenta a necessidade de energia e, portanto, a pot\u00eancia a ser comutada. Um caso para a utiliza\u00e7\u00e3o de um rel\u00e9.<\/p>\n\n\n\n<p>A cablagem destes interruptores \u00e9 normalmente em ponte: todos os p\u00f3los positivos e negativos est\u00e3o ligados uns aos outros. A carga ligada atrav\u00e9s do \u00faltimo interrutor recebe a sua corrente atrav\u00e9s de todas as pontes anteriores. Isto significa que a soma das correntes de todas as cargas ligadas n\u00e3o deve exceder a capacidade da linha de alimenta\u00e7\u00e3o.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"395\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-1024x395.png\" alt=\"\" class=\"wp-image-10085\" style=\"width:513px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-1024x395.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-300x116.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-768x296.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16-18x7.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-16.png 1126w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>Os 12 V 20 A normalmente indicados pelo fabricante referem-se, de facto, apenas ao comprimento padr\u00e3o do cabo de alguns cent\u00edmetros. Se for inclu\u00eddo apenas UM metro de cabo de alimenta\u00e7\u00e3o, a corrente admiss\u00edvel \u00e9 de apenas 2 A, um d\u00e9cimo!<\/p>\n\n\n\n<p>A este respeito, a utiliza\u00e7\u00e3o de rel\u00e9s de comuta\u00e7\u00e3o (contactos normalmente abertos) \u00e9, portanto, mais do que aconselh\u00e1vel.<\/p>\n\n\n\n<p>O contacto GRATUITO identificado como \"V\" conduz \u00e0 liga\u00e7\u00e3o 86 de um rel\u00e9, o fio identificado como \"-\" est\u00e1 ligado ao terminal 85.<br>O consumidor obt\u00e9m a sua liga\u00e7\u00e3o \u00e0 terra (menos) diretamente da bateria (ou da liga\u00e7\u00e3o \u00e0 terra do ve\u00edculo), enquanto recebe a liga\u00e7\u00e3o mais atrav\u00e9s da liga\u00e7\u00e3o do rel\u00e9 comutado 87.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"857\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-1024x857.png\" alt=\"\" class=\"wp-image-10083\" style=\"width:517px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-1024x857.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-300x251.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-768x643.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-1536x1286.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14-14x12.png 14w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/image-14.png 2034w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>Se o interrutor associado for agora acionado, o rel\u00e9 recebe um sinal positivo no contacto 86, recolhe e comuta atrav\u00e9s do seu contacto (30 - positivo) para o contacto oposto 87, onde a carga tamb\u00e9m recebe um sinal positivo e \u00e9 assim ligada. Assim que o interrutor \u00e9 desligado novamente, o rel\u00e9 cai e desconecta a alimenta\u00e7\u00e3o de energia para a carga.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>Relais dienen dem Schalten von Verbrauchern (Lasten) h\u00f6herer Leistung (W &#8211; Watt &#8211; P) als der Schaltkontakt des Schalters oder des Kabelquerschnitts am Schalter es zulassen w\u00fcrde. Jeder kennt im Auto das rhythmische Klacken des Blinker-Relais. Eine integrierte Elektronik sorgt f\u00fcr das gesetzlich vorgeschriebene Blinkintervall und schaltet das Relais ein und aus. Im gleichen Takt&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/06\/17\/wozu-braucht-man-relais\/\" rel=\"bookmark\">Ler mais \"<span class=\"screen-reader-text\">Porque \u00e9 que precisa de rel\u00e9s?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2588,5081],"tags":[2382,2384,5084,5085,5087,2881,4474,5090,5089,1432,1060,5092,5088,5093,5082,2882,5097,1280,5083,5095,1062,981,448,459,446,642,444,466,1415,1378,5094,5091,5096],"class_list":["post-10071","post","type-post","status-publish","format-standard","hentry","category-kfz-technik","category-relais-technik","tag-12v","tag-24v","tag-5084","tag-5085","tag-5087","tag-ampere","tag-blinker-relais","tag-freilaufdiode","tag-funkenloeschdiode","tag-gleichspannung","tag-kabelquerschnitt","tag-kabelrolle","tag-last","tag-leistungsrelais","tag-oeffner","tag-ohm","tag-polung","tag-relais","tag-schliesser","tag-schutzschaltung","tag-sicherung","tag-sicherungsautomat","tag-spannung","tag-spannungsabfall","tag-strom","tag-stromstaerke","tag-stromverbrauch","tag-verbraucher","tag-volt","tag-watt","tag-wechsler","tag-widerstand","tag-zeitrelais"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/10071","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/comments?post=10071"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/10071\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/media?parent=10071"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/categories?post=10071"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/tags?post=10071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}