{"id":10602,"date":"2025-07-24T06:19:21","date_gmt":"2025-07-24T06:19:21","guid":{"rendered":"https:\/\/csiag.eu\/?p=10602"},"modified":"2026-03-11T17:23:11","modified_gmt":"2026-03-11T17:23:11","slug":"atualizacao-do-starlink-gen2-para-gen3","status":"publish","type":"post","link":"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/","title":{"rendered":"Atualiza\u00e7\u00e3o da Starlink Gen2 para Gen3"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#DC-_und_AC-Versorgung\" >Alimenta\u00e7\u00e3o DC e AC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Antennen-Positionierung\" >Posicionamento da antena<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Stationarer_Einsatz\" >Uso estacion\u00e1rio<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#%E2%80%A6_bei_Schneefall\" >... durante a queda de neve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Einsatz_wahrend_der_Fahrt\" >Utiliza\u00e7\u00e3o durante a viagem<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Lieferumfang\" >\u00c2mbito da entrega<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Verkabelung\" >cabeamento<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#WLAN_deaktivieren\" >Desativar WLAN<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Starlink-App\" >Aplicativo StarLink<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Statistik\" >estat\u00edsticas<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Storungen\" >Avarias<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Ping-Erfolg\" >Sucesso do ping<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Latenz\" >lat\u00eancia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Leistungsaufnahme\" >Consumo de energia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Durchsatz\" >Rendimento<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Netzwerk\" >rede<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Gerate\" >Dispositivos<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Zugangspunkte\" >Pontos de acesso<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Storungen-2\" >Avarias<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Ausrichtung\" >Alinhamento<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Geschwindigkeitstest\" >Teste de velocidade<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Einstellungen\" >Configura\u00e7\u00f5es<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Schneeschmelze\" >Neve derretida<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Software-Updates\" >Actualiza\u00e7\u00f5es de software<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Neigung_nur_Gen2\" >Inclina\u00e7\u00e3o (apenas Gen2)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Storungskarte_zurucksetzen\" >Repor o mapa de avarias<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Starlink_verstauen_nur_Gen2\" >Acomodar o Starlink (apenas Gen2)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Starlink_neu_starten\" >Reiniciar o Starlink<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Reset_auf_Werkseinstellungen\" >Repor as defini\u00e7\u00f5es de f\u00e1brica<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Support\" >Apoiar<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Montage\" >Conjunto<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Montage_Gen2_%E2%80%93_Fallback\" >Montagem Gen2 - Fallback<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/#Praxis-Erfahrung_mit_Gen3\" >Experi\u00eancia pr\u00e1tica com a Gen3<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 8<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p>Aquando da atualiza\u00e7\u00e3o, a diferen\u00e7a visual mais \u00f3bvia entre as variantes Starlink Gen2 (V2) e Gen3 (V4) \u00e9 o tamanho de 73 cm<sup>2<\/sup> maior superf\u00edcie de antena da Gen3.<\/p>\n\n\n\n<p>Tecnicamente, a Gen3 tem uma liga\u00e7\u00e3o mais est\u00e1vel e uma velocidade de dados mais elevada, mas isto tamb\u00e9m resulta num consumo de energia 25 W superior.<br>No entanto, os dados t\u00e9cnicos revelam-se bastante generosos a este respeito, pois 30 ... 32 W de consumo m\u00e9dio (27 ... 37 W) est\u00e1 muito longe dos 75 ... 100 W. No entanto, se ligarmos o aquecimento, podemos acrescentar cerca de 52 W e chegar a 79 ... 82 W, ou seja, dentro do intervalo de pot\u00eancia necess\u00e1rio especificado.<br>Quer a WLAN esteja activada ou a funcionar em modo bypass, o consumo praticamente n\u00e3o se altera.<\/p>\n\n\n\n<p>Mecanicamente, a antena foi concebida para velocidades de vento at\u00e9 100 km\/h, anteriormente at\u00e9 80 km\/h. Na pr\u00e1tica, a Gen2 resistiu a velocidades at\u00e9 100 km\/h sem qualquer problema.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"DC-_und_AC-Versorgung\"><\/span>Alimenta\u00e7\u00e3o DC e AC<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Para os propriet\u00e1rios de autocaravanas e para a utiliza\u00e7\u00e3o em barcos, a alimenta\u00e7\u00e3o de tens\u00e3o direta original do Gen3 com uma escolha de 12 ... 30 V ou 57 V de tens\u00e3o cont\u00ednua (DC) \u00e9 muito conveniente para o utilizador. No entanto, o router e a antena s\u00f3 funcionam a partir de 48 V, a tens\u00e3o de alimenta\u00e7\u00e3o POE t\u00edpica, que pode ser realizada atrav\u00e9s de um conversor DCDC de 12 V para 48 V CC.<br>O motivo pelo qual a tens\u00e3o de alimenta\u00e7\u00e3o \u00e9 declarada como 12 ... 30 V DC, para al\u00e9m dos 57 V nominais, ainda n\u00e3o \u00e9 claro.<br>Com a Gen2, era necess\u00e1rio introduzir o <a href=\"https:\/\/csiag.eu\/pt\/starlink-sem-230-a-c\/\" data-type=\"post\" data-id=\"6771\" target=\"_blank\" rel=\"noreferrer noopener\">Bolsa de truques<\/a> se quisesse fazer funcionar a antena com POE e os 48 V normalmente utilizados para o efeito, a menos que dispusesse de corrente alterna de 230 V (CA).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Antennen-Positionierung\"><\/span>Posicionamento da antena<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Enquanto a Gen2, gra\u00e7as ao seu posicionamento motorizado, era capaz de encontrar os seus pr\u00f3prios alvos no c\u00e9u e, assim, alinh\u00e1-los de forma \u00f3ptima, a Gen3, sem esta op\u00e7\u00e3o, tem de se contentar com a posi\u00e7\u00e3o dada ou gerir a forma\u00e7\u00e3o do feixe atrav\u00e9s do \u00e2ngulo de abertura de 110\u00b0 em vez dos anteriores 100\u00b0. Isto significa que a nova antena Gen3 pode ter de ser montada um pouco mais alto do que a antiga Gen2.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Stationarer_Einsatz\"><\/span>Uso estacion\u00e1rio<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Se utilizar o Gen3 de forma estacion\u00e1ria, vale a pena testar a dire\u00e7\u00e3o ideal utilizando os sucessos e os tempos de ping.<\/p>\n\n\n\n<p>Em geral, especialmente em zonas arborizadas, a altura das \u00e1rvores n\u00e3o deve ser subestimada e a antena deve ser colocada o mais alto poss\u00edvel.<br>A quest\u00e3o de saber se as copas das \u00e1rvores conduzem a uma antena \"coberta\" e \u00e0s correspondentes marcas vermelhas no gr\u00e1fico de interfer\u00eancias tornar-se-\u00e1 evidente ap\u00f3s cerca de uma hora de funcionamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"%E2%80%A6_bei_Schneefall\"><\/span>... durante a queda de neve<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>O aquecedor de antena incorporado funciona de forma bastante satisfat\u00f3ria em modo autom\u00e1tico durante uma queda de neve normal e intermitente.<\/p>\n\n\n\n<p>Em caso de queda de neve intensa ou prolongada, tem sido \u00fatil deixar o aquecimento em funcionamento cont\u00ednuo. Deste modo, evita-se a acumula\u00e7\u00e3o de neve na parte inferior da antena, que pode ent\u00e3o inchar e formar lentamente uma parede de gelo.<br>Embora isto reduza apenas marginalmente o desempenho da rece\u00e7\u00e3o, os tempos de ping s\u00e3o mais longos.<\/p>\n\n\n\n<p>O modo de aquecimento cont\u00ednuo garante uma rece\u00e7\u00e3o consistentemente limpa, tempos de ping curtos e o rendimento habitual, mesmo com fortes nev\u00f5es.<br>\u201eAs \u201cinterrup\u00e7\u00f5es\" limitam-se a cerca de duas d\u00fazias por dia, mas n\u00e3o s\u00e3o significativas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Einsatz_wahrend_der_Fahrt\"><\/span>Utiliza\u00e7\u00e3o durante a viagem<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Quem utilizar a tarifa de viagem obter\u00e1 certamente melhores resultados com a Gen3, apesar da falta de alinhamento ideal, devido \u00e0s melhores carater\u00edsticas t\u00e9cnicas da antena.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Lieferumfang\"><\/span>\u00c2mbito da entrega<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A embalagem inclui a antena, o router e a fonte de alimenta\u00e7\u00e3o. O cabo da antena tem uns generosos 15 metros de comprimento e possui um conetor CAT normalizado em ambas as extremidades. A fonte de alimenta\u00e7\u00e3o tem uma ficha DC normalizada de 5,5 x 2,1 mm no lado DC e o cabo de alimenta\u00e7\u00e3o mede 1,5 m.<br>Se n\u00e3o pretender utilizar uma fonte de alimenta\u00e7\u00e3o de 230 V e dispuser de uma fonte de alimenta\u00e7\u00e3o CC de 12 - 30 V (normalmente 12 ou 24 V), pode fornecer rapidamente a tens\u00e3o de funcionamento com um cabo devidamente equipado.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verkabelung\"><\/span>cabeamento<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A antena e a liga\u00e7\u00e3o DC no router est\u00e3o identificadas, enquanto duas tomadas LAN RJ45 est\u00e3o escondidas sob uma cobertura de borracha. Retire a tampa e as tomadas LAN ficam acess\u00edveis. \u00c9 indiferente qual das duas liga\u00e7\u00f5es est\u00e1 ligada ao seu pr\u00f3prio router.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"WLAN_deaktivieren\"><\/span>Desativar WLAN<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>O Wi-Fi do router Starlink pode ser desligado atrav\u00e9s das defini\u00e7\u00f5es da aplica\u00e7\u00e3o, activando o modo bypass. Para reativar o Wi-Fi, \u00e9 necess\u00e1rio repor as defini\u00e7\u00f5es de f\u00e1brica.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Starlink-App\"><\/span>Aplicativo StarLink<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A aplica\u00e7\u00e3o Starlink fornece as seguintes informa\u00e7\u00f5es sobre o estado do sat\u00e9lite e da liga\u00e7\u00e3o \u00e0 Internet:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Statistik\"><\/span>estat\u00edsticas<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Todos os valores s\u00e3o acumulados durante um intervalo de medi\u00e7\u00e3o de 15 minutos.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"369\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Statistik_Gen3.png\" alt=\"\" class=\"wp-image-10660\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Statistik_Gen3.png 369w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Statistik_Gen3-138x300.png 138w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Statistik_Gen3-6x12.png 6w\" sizes=\"(max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Storungen\"><\/span>Avarias<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>As interfer\u00eancias de rece\u00e7\u00e3o, tais como sat\u00e9lites obscurecidos ou buscas de sat\u00e9lites, s\u00e3o listadas aqui e a dura\u00e7\u00e3o \u00e9 apresentada em segundos. 0,00 segundos \u00e9 bastante realista no caso ideal, embora alguns minutos de inatividade tamb\u00e9m sejam poss\u00edveis. Um alinhamento cuidadoso, incluindo a altura da antena, compensa neste caso.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ping-Erfolg\"><\/span>Sucesso do ping<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>O sucesso do ping indica a percentagem de um ping enviado que recebeu uma resposta. Valores de 100% s\u00e3o, de facto, praticamente alcan\u00e7\u00e1veis.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Latenz\"><\/span>lat\u00eancia<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>A lat\u00eancia \u00e9 o tempo que decorre entre um pedido e a chegada da resposta e deve ser inferior a 50 ms.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leistungsaufnahme\"><\/span>Consumo de energia<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>O consumo m\u00e9dio de energia da antena e do router \u00e9 apresentado aqui em watts. Quando o aquecimento da antena est\u00e1 ligado quando a neve est\u00e1 a derreter, este pode atingir cerca de 100 W, enquanto o consumo normal \u00e9 de cerca de 70 W.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Durchsatz\"><\/span>Rendimento<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Dependendo do comportamento de navega\u00e7\u00e3o, as velocidades de descarregamento e carregamento s\u00e3o determinadas em MBit\/s. Da mesma forma, a aplica\u00e7\u00e3o oferece um teste de velocidade que tamb\u00e9m apresenta a lat\u00eancia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Netzwerk\"><\/span>rede<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Gerate\"><\/span>Dispositivos<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Os dispositivos ligados ao router Starlink s\u00e3o listados aqui.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Zugangspunkte\"><\/span>Pontos de acesso<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>O router Starlink est\u00e1 listado neste item de menu, bem como a op\u00e7\u00e3o de configurar uma rede em malha.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Storungen-2\"><\/span>Avarias<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Uma vez lan\u00e7ado o Starlink, a antena recolhe dados sobre a acessibilidade dos sat\u00e9lites durante um per\u00edodo de cerca de uma hora, a fim de registar e apresentar os obst\u00e1culos.<\/p>\n\n\n\n<p>Um diagrama que mostra o segmento esf\u00e9rico em forma de c\u00fapula coberto pela antena fornece informa\u00e7\u00f5es mais detalhadas ao longo do tempo. <\/p>\n\n\n\n<p>N\u00e3o s\u00e3o vis\u00edveis quaisquer \u00e1reas coloridas ap\u00f3s a configura\u00e7\u00e3o inicial. A antena regista os sinais de rece\u00e7\u00e3o de sat\u00e9lite e reconhece as \u00f3rbitas que estes tomam. Enquanto conseguir ver os sat\u00e9lites, \u00e9 definido um p\u00edxel azul. Assim que o sat\u00e9lite deveria estar l\u00e1, mas \u00e9 obscurecido por um obst\u00e1culo, \u00e9 definido um p\u00edxel vermelho.<\/p>\n\n\n\n<p>Em cerca de uma hora, a imagem est\u00e1 conclu\u00edda e os eventuais obst\u00e1culos tornam-se claramente vis\u00edveis.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"369\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Stoerungen.png\" alt=\"\" class=\"wp-image-10658\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Stoerungen.png 369w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Stoerungen-138x300.png 138w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Stoerungen-6x12.png 6w\" sizes=\"(max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ausrichtung\"><\/span>Alinhamento<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A posi\u00e7\u00e3o da antena Starlink \u00e9 mostrada aqui numa rosa dos ventos. Se o alinhamento estiver correto, a antena \u00e9 localizada graficamente dentro de uma moldura desenhada.<\/p>\n\n\n\n<p>Se a orienta\u00e7\u00e3o for incorrecta, \u00e9 indicado o sentido de rota\u00e7\u00e3o, complementado por uma indica\u00e7\u00e3o de graus, que, no entanto, \u00e9 enganadora, uma vez que uma rota\u00e7\u00e3o de cerca de 34\u00b0 corresponde fisicamente a uma rota\u00e7\u00e3o \"medida\" de cerca de 6\u00b0 ...<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Geschwindigkeitstest\"><\/span>Teste de velocidade<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u00c9 apresentado o d\u00e9bito de dados para descarregamento e carregamento em MBit\/s e o tempo de ping em ms.<\/p>\n\n\n\n<p>Sob o item de menu <em>Alargado<\/em> os testes de velocidade podem ser efectuados separadamente entre o dispositivo final e o router e entre o dispositivo final e a Internet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Einstellungen\"><\/span>Configura\u00e7\u00f5es<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Schneeschmelze\"><\/span>Neve derretida<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Existem tr\u00eas modos de funcionamento poss\u00edveis:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fora de<\/li>\n\n\n\n<li>Autom\u00e1tico<\/li>\n\n\n\n<li>Pr\u00e9-aquecimento<\/li>\n<\/ul>\n\n\n\n<p>Nas esta\u00e7\u00f5es sem neve, a op\u00e7\u00e3o OFF pode ser selecionada para evitar de forma fi\u00e1vel o aumento do consumo de energia.<\/p>\n\n\n\n<p>Se estiver prevista a ocorr\u00eancia de neve, o sistema autom\u00e1tico detecta automaticamente a queda de neve e ativa o aquecimento a\u00e9reo enquanto estiver a nevar, a fim de manter uma vis\u00e3o desimpedida.<\/p>\n\n\n\n<p>Em caso de chuva gelada, pode ser utilizado o modo de pr\u00e9-aquecimento, que tamb\u00e9m evita a chuva gelada e descongela rapidamente a neve ca\u00edda em caso de queda de neve.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Software-Updates\"><\/span>Actualiza\u00e7\u00f5es de software<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>O Starlink descarrega e instala as actualiza\u00e7\u00f5es automaticamente. Podem ser predefinidas quatro horas diferentes, com intervalos de seis horas a partir das 3 horas da manh\u00e3, para que os utilizadores n\u00e3o sejam incomodados por rein\u00edcios durante o seu hor\u00e1rio de trabalho.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Neigung_nur_Gen2\"><\/span>Inclina\u00e7\u00e3o (apenas Gen2)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>A inclina\u00e7\u00e3o da antena Gen2 pode ser alternada entre horizontal e inclinada. A posi\u00e7\u00e3o horizontal era um compromisso entre a resist\u00eancia ao vento e a qualidade da rece\u00e7\u00e3o.<\/p>\n\n\n\n<p>A antena Gen3 n\u00e3o oferece esta op\u00e7\u00e3o de ajuste devido \u00e0 falta de um acionamento motorizado.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Storungskarte_zurucksetzen\"><\/span>Repor o mapa de avarias<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Esta op\u00e7\u00e3o permite-lhe apagar o mapa de interfer\u00eancias. Se tiverem sido feitas altera\u00e7\u00f5es no posicionamento da antena, o mapa de interfer\u00eancias deve ser reposto e apagado, de modo a obter uma vis\u00e3o geral actualizada dos locais onde ainda existem interfer\u00eancias. Desta forma, a posi\u00e7\u00e3o ideal pode ser determinada passo a passo.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Starlink_verstauen_nur_Gen2\"><\/span>Acomodar o Starlink (apenas Gen2)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>A arruma\u00e7\u00e3o parece um pouco estranha, porque a antena s\u00f3 se move para uma posi\u00e7\u00e3o aproximadamente vertical, nomeadamente a que \u00e9 adequada para ser acondicionada na embalagem original aquando da entrega.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Starlink_neu_starten\"><\/span>Reiniciar o Starlink<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>No caso de problemas de liga\u00e7\u00e3o aparentemente insol\u00faveis, mas tamb\u00e9m se o acesso a um s\u00edtio Web for negado devido a conflitos de IP, um rein\u00edcio ajudar\u00e1. Cada rein\u00edcio tamb\u00e9m resulta numa nova atribui\u00e7\u00e3o de IP, entre outras coisas.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reset_auf_Werkseinstellungen\"><\/span>Repor as defini\u00e7\u00f5es de f\u00e1brica<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>Embora as pessoas sejam geralmente r\u00e1pidas a premir a panaceia do \"bot\u00e3o de reiniciar\", deveriam ter tentado primeiro todas as outras op\u00e7\u00f5es de resolu\u00e7\u00e3o de problemas. <\/p>\n\n\n\n<p>A reposi\u00e7\u00e3o parece fazer mais do que simplesmente restaurar as defini\u00e7\u00f5es de f\u00e1brica, pois parece um pouco estranho que a reposi\u00e7\u00e3o frequente possa resultar em danos permanentes no hardware.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Support\"><\/span>Apoiar<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Neste item de menu, encontrar\u00e1 uma compila\u00e7\u00e3o de muitos t\u00f3picos no estilo FAQ, tais como <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fatura\u00e7\u00e3o<\/li>\n\n\n\n<li>ordem<\/li>\n\n\n\n<li>Configura\u00e7\u00e3o e instala\u00e7\u00e3o<\/li>\n\n\n\n<li>Resolu\u00e7\u00e3o de problemas<\/li>\n\n\n\n<li>Conta<\/li>\n\n\n\n<li>Planos de servi\u00e7o<\/li>\n\n\n\n<li>Especifica\u00e7\u00f5es e configura\u00e7\u00e3o<\/li>\n<\/ul>\n\n\n\n<p>bem como uma liga\u00e7\u00e3o para o servi\u00e7o de apoio Starlink, que \u00e9 muito orientado para o cliente e eficiente quando se entra em contacto com um funcion\u00e1rio humano real em vez de um bot in\u00fatil.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Montage\"><\/span>Conjunto<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A antena \u00e9 fornecida com uma base articulada e intermut\u00e1vel. Se pretender montar a antena de forma permanente, necessita de um suporte de mastro de alum\u00ednio correspondente, que \u00e9 trocado pela vers\u00e3o articulada.<\/p>\n\n\n\n<p>O suporte montado de s\u00e9rie \u00e9 retirado \"dobrando\" (com for\u00e7a) a parte inferior, mais fina, que liberta dois fechos da caixa da antena e permite que o suporte seja puxado para fora.<\/p>\n\n\n\n<p>O suporte do mastro de alum\u00ednio \u00e9 inserido no suporte da antena e empurrado para a frente at\u00e9 encaixar no lugar.<\/p>\n\n\n\n<p>Com um di\u00e2metro de 68 mm, acho que o suporte do mastro \u00e9 um pouco volumoso demais. Se tamb\u00e9m for poss\u00edvel fixar um mastro \"mais fino\" de, por exemplo, 42 mm, com os dois parafusos Allen, eu preferiria uma liga\u00e7\u00e3o de for\u00e7a total.<\/p>\n\n\n\n<p>Um encaixe de PVC de 2,5\u2033 \/ acoplamento de tubo, equipado com duas camadas de tubo termorretr\u00e1ctil, resulta num adaptador de tubo perfeitamente ajustado a um tubo de alum\u00ednio de 42 mm.<br>Nota: a liga\u00e7\u00e3o roscada em PVC \u00e9 ligeiramente elevada num ponto. Como o suporte Starlink tem uma reentr\u00e2ncia que acomoda esta \u00e1rea elevada, isto n\u00e3o constitui um problema e pode retirar facilmente o adaptador inserido em qualquer altura.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_1.png\" alt=\"\" class=\"wp-image-10631\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_1.png 600w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_1-225x300.png 225w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_1-9x12.png 9w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_2.png\" alt=\"\" class=\"wp-image-10632\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_2.png 600w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_2-225x300.png 225w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_2-9x12.png 9w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p>Os dois orif\u00edcios roscados do suporte de antena Starlink s\u00e3o transferidos para o adaptador de tubo fabricado desta forma. Perfurar 8 mm de um lado nas marca\u00e7\u00f5es, para que os dois parafusos possam alcan\u00e7ar o tubo de alum\u00ednio inserido e evitar que este escorregue.<\/p>\n\n\n\n<p>Uma vez que o di\u00e2metro interior do encaixe de PVC na parte roscada f\u00eamea corresponde ao di\u00e2metro do tubo necess\u00e1rio, mas \u00e9 maior no lado oposto, o di\u00e2metro da extremidade do tubo deve ser ajustado \u00e0 profundidade do orif\u00edcio maior utilizando tubos retr\u00e1cteis at\u00e9 se conseguir uma liga\u00e7\u00e3o de encaixe for\u00e7ado.<\/p>\n\n\n\n<p>O adaptador \u00e9 ent\u00e3o empurrado sobre o tubo a partir de baixo at\u00e9 chegar \u00e0 extremidade do tubo, cujo di\u00e2metro foi aumentado com tubos retr\u00e1cteis, e sela o tubo.<\/p>\n\n\n\n<p>Antes da montagem final, os dois orif\u00edcios no \"adaptador\" de PVC s\u00e3o transferidos para o tubo de alum\u00ednio e s\u00e3o tamb\u00e9m efectuados orif\u00edcios de 8 mm para que os parafusos possam passar atrav\u00e9s desta parede do tubo e fixar o tubo no interior oposto.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_Bohrungen.png\" alt=\"\" class=\"wp-image-10633\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_Bohrungen.png 600w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_Bohrungen-225x300.png 225w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_Bohrungen-9x12.png 9w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_eingesetzt.png\" alt=\"\" class=\"wp-image-10634\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_eingesetzt.png 600w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_eingesetzt-225x300.png 225w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Rohrhalterung_eingesetzt-9x12.png 9w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p>A quest\u00e3o de afiar as roscas dos parafusos na parte da frente para obter um melhor efeito de fixa\u00e7\u00e3o no lado do tubo fica ao seu crit\u00e9rio.<\/p>\n\n\n\n<p>Depois de apertar os dois parafusos (aqui foram utilizados os parafusos TX-V2A, que s\u00e3o cerca de 10 mm mais compridos do que os parafusos galvanizados fornecidos), o mastro pode ser erguido, fixado e colocado em funcionamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Montage_Gen2_%E2%80%93_Fallback\"><\/span>Montagem Gen2 - Fallback<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>O Gen2 regressou agora \u00e0 sua antiga base, depois de n\u00e3o ter conseguido obter uma liga\u00e7\u00e3o por sat\u00e9lite permanentemente perfeita na traseira do ve\u00edculo devido aos \"obst\u00e1culos\" no topo das \u00e1rvores.<br>O Gen2 tamb\u00e9m pode permanecer nesta posi\u00e7\u00e3o durante a viagem, enquanto o mastro do Gen3 tem de ser removido antes de iniciar a viagem. No entanto, uma vez que se trata apenas de desapertar um parafuso Allen e desligar o cabo de rede da antena, n\u00e3o \u00e9 um grande problema.<\/p>\n\n\n\n<p>Isto tamb\u00e9m permite uma boa compara\u00e7\u00e3o dos tamanhos.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_-768x1024.png\" alt=\"\" class=\"wp-image-10686\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_-768x1024.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_-225x300.png 225w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_-9x12.png 9w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_.png 900w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen2_-768x1024.png\" alt=\"\" class=\"wp-image-10685\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen2_-768x1024.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen2_-225x300.png 225w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen2_-9x12.png 9w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen2_.png 900w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Praxis-Erfahrung_mit_Gen3\"><\/span>Experi\u00eancia pr\u00e1tica com a Gen3<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A configura\u00e7\u00e3o \u00e9 simples no que respeita \u00e0s liga\u00e7\u00f5es dos cabos. No entanto, a orienta\u00e7\u00e3o da antena, de acordo com a aplica\u00e7\u00e3o, \u00e9 um pouco confusa: se a antena estiver \"34\u00b0 desalinhada\", de acordo com a aplica\u00e7\u00e3o, tem de a rodar cerca de 130\u00b0. No entanto, a dire\u00e7\u00e3o indicada est\u00e1 correta.<br>Uma rota\u00e7\u00e3o de 34\u00b0 na dire\u00e7\u00e3o especificada resultou na mensagem de que a antena estava agora desalinhada em \"28\u00b0\". Ent\u00e3o: uma rota\u00e7\u00e3o (aprox.) de 34\u00b0 corresponde a 6\u00b0 de rota\u00e7\u00e3o efectiva ...<\/p>\n\n\n\n<p>Se o alinhamento estiver correto, n\u00e3o s\u00f3 ser\u00e1 recompensado com taxas de dados significativamente melhores, como tamb\u00e9m com tempos de ping mais curtos, tal como a confirma\u00e7\u00e3o visual de que o alinhamento da antena est\u00e1 agora \"em linha\".<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"369\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_Ausrichtung.png\" alt=\"\" class=\"wp-image-10641\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_Ausrichtung.png 369w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_Ausrichtung-138x300.png 138w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Starlink_Gen3_Ausrichtung-6x12.png 6w\" sizes=\"(max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"369\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen3_Geschwindigkeitstest.png\" alt=\"\" class=\"wp-image-10644\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen3_Geschwindigkeitstest.png 369w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen3_Geschwindigkeitstest-138x300.png 138w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen3_Geschwindigkeitstest-6x12.png 6w\" sizes=\"(max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p>Em compara\u00e7\u00e3o, um teste de velocidade com o Gen2 no mesmo local:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"369\" height=\"800\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen2_Geschwindigkeitstest.png\" alt=\"\" class=\"wp-image-10688\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen2_Geschwindigkeitstest.png 369w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen2_Geschwindigkeitstest-138x300.png 138w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/07\/Gen2_Geschwindigkeitstest-6x12.png 6w\" sizes=\"(max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 8<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>Bei einem Upgrade ist der deutlichste optische Unterschied zwischen der Starlink Gen2 (V2) und Gen3 (V4)-Variante die um 73 cm2 gr\u00f6\u00dfere Antennenfl\u00e4che der Gen3. Technisch weist die Gen3 eine stabilere Verbindung und eine h\u00f6here Datengeschwindigkeit auf, was allerdings auch einen um 25 W h\u00f6heren Stromverbrauch bedingt.Dennoch erweisen sich die Technischen Daten diesbez\u00fcglich als recht gro\u00dfz\u00fcgig&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/pt\/blog\/2025\/07\/24\/upgrade-starlink-gen2-auf-gen3\/\" rel=\"bookmark\">Ler mais \"<span class=\"screen-reader-text\">Atualiza\u00e7\u00e3o da Starlink Gen2 para Gen3<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2553,2877],"tags":[5277,2382,2384,5274,5275,5304,839,5315,5314,5269,5279,5285,5291,5305,5270,5271,840,5276,5294,5284,5306,5298,5265,918,5295,604,5288,813,5303,573,5307,5280,2092,5283,5311,5282,2979,571,906,2068,5302,570,2793,5278,786,5292,5313,5312,574,1397,5290,5273,5296,4797,5308,5297,5309,5310,2711,5281,408,2309,5287,5299,547,5268,5267,5266,3388,5289,5272,835,5301,874,5293,2259,563,5286,5300],"class_list":["post-10602","post","type-post","status-publish","format-standard","hentry","category-netzwerk-technik","category-starlink","tag-gleichspannung-2","tag-12v","tag-24v","tag-48v","tag-57v","tag-abrechnung","tag-ac","tag-adapter","tag-aluminium-rohr","tag-antennenflaeche","tag-antennerj45","tag-ausfaelle","tag-ausrichtung","tag-bestellung","tag-bypass","tag-bypass-modus","tag-dc","tag-dcdc-wandler-2","tag-drehrichtung","tag-durchsatzdatendurchsatz","tag-einrichtung","tag-empfangsqualitaet","tag-gen3","tag-geraete","tag-geschwindigkeitstest","tag-heizen","tag-hindernisse","tag-installation","tag-ip-vergabe","tag-konfiguration","tag-konto","tag-lan-buchse","tag-latenz","tag-leistungsaufnahme","tag-masthalterung","tag-messintervall","tag-montage","tag-neigung","tag-netzteil","tag-netzwerk","tag-neustart","tag-oeffnungswinkel","tag-ping","tag-ping-erfolg","tag-poe","tag-position","tag-pvc-rohrkupplung","tag-pvc-verschraubung","tag-router","tag-satellit","tag-satelliten","tag-schnee-schmelzen","tag-schneeschmelze","tag-schrumpfschlauch","tag-serviceplaene","tag-software-updates","tag-spezifikationen","tag-standfuss","tag-starlink","tag-starlink-app","tag-statistik","tag-status","tag-stoerungen","tag-stoerungskarte","tag-support","tag-upgrade","tag-v2","tag-v4","tag-verbrauch","tag-verdeckt","tag-vorwaermen","tag-wechselspannung","tag-werksreset","tag-windgeschwindigkeit","tag-windrose","tag-windwiderstand","tag-wlan","tag-zugangspunkte","tag-zuruecksetzen"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/10602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/comments?post=10602"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/10602\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/media?parent=10602"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/categories?post=10602"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/tags?post=10602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}