{"id":4373,"date":"2023-05-12T17:19:13","date_gmt":"2023-05-12T17:19:13","guid":{"rendered":"https:\/\/csiag.eu\/?p=4373"},"modified":"2023-06-15T19:51:58","modified_gmt":"2023-06-15T19:51:58","slug":"smartmeter-evitar-electrosmog","status":"publish","type":"post","link":"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/","title":{"rendered":"Smartmeter \u2013 evite eletrosmog"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Rundsteuer-Empfanger\" >Recetor de controlo de ondula\u00e7\u00e3o<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Datenubertragungsverfahren_und_Frequenzen\" >M\u00e9todos e frequ\u00eancias de transmiss\u00e3o de dados<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Mobilfunknetz\" >Rede m\u00f3vel<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#PLC\" >CLP<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#DSL\" >DSL<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/#Fazit\" >Conclus\u00e3o<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p>Contadores inteligentes - um tema quente nos dias de hoje, especialmente em rela\u00e7\u00e3o ao electrosmog.<\/p>\n\n\n\n<p>O bom e velho contador mec\u00e2nico Ferraris vai tornar-se obsoleto e ser substitu\u00eddo por contadores electr\u00f3nicos inteligentes, os chamados smart meters, em toda a parte. O objetivo \u00e9 poupar no pessoal que costumava ler os contadores antigos. Era tamb\u00e9m um enorme encargo administrativo deixar um cart\u00e3o de leitura do contador quando os clientes estavam ausentes no momento da leitura, que o cliente tinha de enviar \u00e0 empresa de servi\u00e7os p\u00fablicos juntamente com a leitura do contador, para que esta pudesse ser transferida manualmente para o sistema inform\u00e1tico e a fatura pudesse ent\u00e3o ser criada.<\/p>\n\n\n\n<p>Os pioneiros dos contadores inteligentes s\u00e3o os dispositivos electr\u00f3nicos de dete\u00e7\u00e3o de calor, que podem ser lidos por um ve\u00edculo que passe pelos apartamentos e esteja equipado com o equipamento adequado. Este processo \u00e9 mais r\u00e1pido do que o registo manual e \u00e9 tamb\u00e9m independente de um eventual acesso aos radiadores dos apartamentos.<\/p>\n\n\n\n<p>Os dados dos contadores inteligentes devem agora ser registados de forma centralizada, em intervalos de quinze minutos, ou seja, n\u00e3o apenas no final de um per\u00edodo de fatura\u00e7\u00e3o, como acontece normalmente ao fim de um ano.<\/p>\n\n\n\n<p>Os defensores da prote\u00e7\u00e3o de dados est\u00e3o em p\u00e9 de guerra. Em \u00faltima an\u00e1lise, o comportamento de consumo pode ser monitorizado, incluindo a presen\u00e7a ou aus\u00eancia, o que pode ser utilizado indevidamente. Al\u00e9m disso, o fornecedor poderia tamb\u00e9m desligar a fonte de alimenta\u00e7\u00e3o \u00e0 dist\u00e2ncia, e muitas outras coisas seriam muito f\u00e1ceis de implementar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rundsteuer-Empfanger\"><\/span>Recetor de controlo de ondula\u00e7\u00e3o<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Os receptores de controlo de ondula\u00e7\u00e3o s\u00e3o utilizados para ajustar automaticamente a produ\u00e7\u00e3o dos sistemas fotovoltaicos que alimentam a rede e destinam-se a evitar a sobreprodu\u00e7\u00e3o e, consequentemente, desvios ascendentes na frequ\u00eancia da rede.<\/p>\n\n\n\n<p>Se os habituais 50 Hz se desviarem para cima em apenas 0,2 Hz, a pot\u00eancia de sa\u00edda dos sistemas fotovoltaicos \u00e9 estrangulada por comando de controlo remoto e desligada completamente a 51,5 Hz.<\/p>\n\n\n\n<p>Os controladores BPR poderiam reconhecer a sobreprodu\u00e7\u00e3o e canalizar a energia excedente de forma mais sensata, por exemplo, para serpentinas de aquecimento em tanques de armazenamento de reserva, a fim de a converter em calor em vez de a destruir por estrangulamento ou desligamento total.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Datenubertragungsverfahren_und_Frequenzen\"><\/span>M\u00e9todos e frequ\u00eancias de transmiss\u00e3o de dados<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Os contadores inteligentes podem transmitir dados \u00e0 empresa de servi\u00e7os p\u00fablicos de diferentes formas. Isto pode ser feito atrav\u00e9s da rede de telem\u00f3veis (utilizando o cart\u00e3o SIM do pr\u00f3prio fornecedor integrado no contador inteligente), atrav\u00e9s de PLC (Power Line Communication) ou por cabo atrav\u00e9s de DSL.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Mobilfunknetz\"><\/span>Rede m\u00f3vel<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A transmiss\u00e3o de dados na rede de telem\u00f3veis \u00e9 feita atrav\u00e9s de pacotes de dados pulsados. Para garantir sempre uma liga\u00e7\u00e3o \u00e0 torre de telem\u00f3vel mais pr\u00f3xima, o contador inteligente envia periodicamente uma chamada de bloqueio. Isto resulta numa exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o a cada poucos segundos.<\/p>\n\n\n\n<p>Est\u00e3o dispon\u00edveis as seguintes frequ\u00eancias HF (alta frequ\u00eancia) com diferentes larguras de banda de 10 a 100 MHz:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Banda 5G SA \/ 700 MHz<\/li>\n\n\n\n<li>Banda LTE 28 \/ 700 MHz<\/li>\n\n\n\n<li>Banda LTE 20 \/ 800 MHz<\/li>\n\n\n\n<li>GSM \/ 890 - 915 MHz<\/li>\n\n\n\n<li>LTE Banda 8 \/ 900 MHz<\/li>\n\n\n\n<li>GSM 900 \/ 935 - 960 MHz<\/li>\n\n\n\n<li>Banda LTE 32 \/ 1.500 MHz<\/li>\n\n\n\n<li>LTE Banda 3 \/ 1.800 MHz<\/li>\n\n\n\n<li>LTE Banda 1 \/ 2.100 MHz<\/li>\n\n\n\n<li>Banda LTE 7 e 38 \/ 2.600 MHz <\/li>\n\n\n\n<li>Banda 5G N78 \/ 3,400 - 3,800 GHz <\/li>\n\n\n\n<li>Banda 5G N85 \/ 26 GHz e 60 GHz (ambas ainda n\u00e3o atribu\u00eddas)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"PLC\"><\/span>CLP<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>O PLC utiliza a linha el\u00e9ctrica como portadora para os fluxos de dados modulados em OFDM (multiplexagem ortogonal por divis\u00e3o de frequ\u00eancia) ou QAM (modula\u00e7\u00e3o de amplitude quadr\u00e1tica) na tecnologia PolyTrax II, um salto de frequ\u00eancia em todas as frequ\u00eancias dispon\u00edveis.<br>Os cabos de antena s\u00e3o normalmente blindados uma ou mais vezes para proteger o sinal real de interfer\u00eancias no caminho da antena para o recetor. No entanto, uma linha el\u00e9ctrica n\u00e3o \u00e9 blindada, nem as linhas de alimenta\u00e7\u00e3o de aparelhos, tomadas, etc.. Estes cabos tornam-se assim antenas e irradiam livremente para o ambiente.<\/p>\n\n\n\n<p>O procedimento PLC utiliza as seguintes gamas de frequ\u00eancia LF (baixa frequ\u00eancia) espec\u00edficas de cada pa\u00eds, de acordo com a norma CENELEC EN 50065-1 (Comit\u00e9 Europeu de Normaliza\u00e7\u00e3o Eletrot\u00e9cnica):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gama de frequ\u00eancias de controlo de ondula\u00e7\u00e3o 110 Hz - 1,6 kHz<\/li>\n\n\n\n<li>- \/ 3 - 9 kHz<\/li>\n\n\n\n<li>Banda A \/ 9 - 95 kHz<\/li>\n\n\n\n<li>Banda B \/ 95 - 125 kHz<\/li>\n\n\n\n<li>Banda C \/ 125 - 140 kHz<\/li>\n\n\n\n<li>Banda D \/ 140 - 148,5 kHz<\/li>\n\n\n\n<li>Banda G3 \/ 155 - 487 kHz (por exemplo, Am\u00e9rica do Norte, Jap\u00e3o)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"DSL\"><\/span>DSL<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Os contadores inteligentes com uma interface LAN utilizam uma liga\u00e7\u00e3o DSL existente para a transmiss\u00e3o de dados e, por conseguinte, funcionam sem sinais de r\u00e1dio. S\u00e3o a alternativa mais sensata aos m\u00e9todos acima referidos em termos de sa\u00fade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Netzfilter\"><span class=\"ez-toc-section\" id=\"Fazit\"><\/span>Conclus\u00e3o<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Qualquer pessoa que sofra de hipersensibilidade el\u00e9ctrica (EHS) ou que, de um modo geral, queira evitar o mais poss\u00edvel o electrosmog, seria aconselh\u00e1vel pedir ao seu fornecedor de energia um contador inteligente com uma interface LAN, se tal for inevit\u00e1vel.<\/p>\n\n\n\n<p>O pr\u00f3ximo mal menor \u00e9 um contador inteligente que utiliza PLC. Neste caso, \u00e9 aconselh\u00e1vel, embora dispendioso, instalar um contador multif\u00e1sico <a href=\"https:\/\/bajog.de\/index.php\/de\/produkte\/netzentst%C3%B6rfilter\/tfskn-filter.html\" target=\"_blank\" rel=\"noreferrer noopener\">Filtro de linha<\/a>como o <a href=\"https:\/\/biopowerrief.at\/products\/netzfilter-35-a-fcc\" target=\"_blank\" rel=\"noreferrer noopener\">Filtro de rede 35 A FCC<\/a> que bloqueiam as frequ\u00eancias PLC e, por conseguinte, n\u00e3o permitem que estas cheguem \u00e0 alimenta\u00e7\u00e3o el\u00e9ctrica interna.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>Contadores inteligentes - um tema quente nos dias que correm, especialmente em rela\u00e7\u00e3o ao electrosmog. O bom e velho contador mec\u00e2nico Ferraris dever\u00e1 tornar-se obsoleto e ser substitu\u00eddo por contadores electr\u00f3nicos inteligentes, os chamados contadores inteligentes, em toda a parte. O objetivo \u00e9 poupar no pessoal que costumava ler os contadores antigos. Era tamb\u00e9m um enorme fardo administrativo enviar um cart\u00e3o de leitura do contador quando os clientes estavam ausentes na altura da leitura...&nbsp;<a href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/05\/12\/smartmeter-elektrosmog-vermeiden\/\" rel=\"bookmark\">Ler mais \"<span class=\"screen-reader-text\">Smartmeter \u2013 evite eletrosmog<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1586,1525,1302,1600],"tags":[1702,1704,1604,1587,1703,1526,1708,1706,1549,725,1701,1602,1603,1707,1705,929,1546],"class_list":["post-4373","post","type-post","status-publish","format-standard","hentry","category-elektrosensibilitaet","category-elektrosmog","category-funktechnik","category-smartmeter","tag-5g","tag-bpr-regler","tag-dsl","tag-ehs","tag-elektrohypersensibilitaet","tag-elektrosmog","tag-frequenz-hopping","tag-frequenzen","tag-gsm","tag-lte","tag-mobilfunknetz","tag-netzfilter","tag-plc","tag-polytrax-ii-technik","tag-rundsteuerempfaenger","tag-smartmeter","tag-strahlenbelastung"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/4373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/comments?post=4373"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/4373\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/media?parent=4373"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/categories?post=4373"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/tags?post=4373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}