{"id":5028,"date":"2023-08-30T12:51:49","date_gmt":"2023-08-30T12:51:49","guid":{"rendered":"https:\/\/csiag.eu\/?p=5028"},"modified":"2024-05-18T14:43:42","modified_gmt":"2024-05-18T14:43:42","slug":"controlo-da-ventoinha-do-frigorifico","status":"publish","type":"post","link":"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/","title":{"rendered":"Geladeira \u2013 Controle do Ventilador"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/#Funktionsweise_Absorber\" >Como funciona o absorvedor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/#Kuhlung_fur_den_Kondensator\" >Arrefecimento do condensador<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/#Lufter-Regelung\" >Controlo do ventilador<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/#Programmierung\" >programa\u00e7\u00e3o<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/#Legende\" >Legenda:<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/#Temperatursensor_im_Gefrierfach\" >Sensor de temperatura no compartimento do congelador<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 5<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p class=\"wp-block-paragraph\">Com os frigor\u00edficos de absor\u00e7\u00e3o, em particular, \u00e9 um problema obter a capacidade de refrigera\u00e7\u00e3o necess\u00e1ria do frigor\u00edfico nas esta\u00e7\u00f5es quentes, especialmente nos climas mais a sul e, por conseguinte, mais quentes. Um sistema de controlo da ventoinha pode ser uma solu\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A diferen\u00e7a entre com e sem ventoinha \u00e9 clara: sem ventoinha, a temperatura no compartimento do congelador situa-se entre 7 ... 11 \u00b0C, com a ventoinha, ap\u00f3s um curto per\u00edodo de tempo -20 \u00b0C! <\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Funktionsweise_Absorber\"><\/span>Como funciona o absorvedor<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ao contr\u00e1rio de um compressor, um absorvedor funciona com \u00e1gua e amon\u00edaco numa atmosfera de hidrog\u00e9nio. O hidrog\u00e9nio actua como um equalizador de press\u00e3o. A \u00e1gua e o amon\u00edaco s\u00e3o aquecidos no chamado \"fog\u00e3o\", utilizando principalmente g\u00e1s, 230 V AC ou 12 V DC, mas tamb\u00e9m gasolina.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O amon\u00edaco torna-se gasoso como resultado do processo de aquecimento. Arrefece atrav\u00e9s do condensador (localizado atr\u00e1s do respiradouro superior na parede da caravana ou autocaravana) e volta a liquefazer-se no evaporador (localizado no compartimento do gelo do frigor\u00edfico), onde o hidrog\u00e9nio compensa as diferen\u00e7as de press\u00e3o que surgem quando o amon\u00edaco volta a evaporar-se e \u00e9 gerado o frio desejado. No absorvedor, o amon\u00edaco volta a entrar em solu\u00e7\u00e3o com a \u00e1gua e o ciclo recome\u00e7a.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uma baixa capacidade de arrefecimento a temperaturas exteriores mais elevadas deve-se ao facto de n\u00e3o ser poss\u00edvel introduzir amon\u00edaco suficiente no evaporador sob a forma liquefeita, uma vez que este n\u00e3o consegue arrefecer o suficiente no seu percurso atrav\u00e9s do condensador.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se o condensador for adicionalmente arrefecido por ventiladores com um maior fluxo de ar, mais amon\u00edaco se liquefaz e a capacidade de arrefecimento aumenta em conformidade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Kuhlung_fur_den_Kondensator\"><\/span>Arrefecimento do condensador<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Alguns frigor\u00edficos de absor\u00e7\u00e3o j\u00e1 t\u00eam uma ou duas ventoinhas adicionais com controlo de temperatura. Se isto n\u00e3o for suficiente, pode remediar a situa\u00e7\u00e3o por si pr\u00f3prio. A SmartHome torna-o poss\u00edvel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Em primeiro lugar, s\u00e3o necess\u00e1rios ventiladores adequados, <a href=\"https:\/\/www.amazon.de\/dp\/B09722FQHV?ref=ppx_yo2ov_dt_b_product_details&amp;th=1\" target=\"_blank\" rel=\"noopener\">esse<\/a> est\u00e3o dispon\u00edveis em embalagens de tr\u00eas unidades (360 x 120 x 25 mm). Em conjunto, t\u00eam um caudal de ar de 7 m<sup>3<\/sup>\/h. Foram concebidos para 12 V CC, mas s\u00e3o fornecidos com uma fonte de alimenta\u00e7\u00e3o de controlo para 230 V. Naturalmente, um controlo de 12 V teria sido melhor. Para poder controlar os ventiladores individualmente, o cabo deve ser cortado diretamente antes da combina\u00e7\u00e3o das tr\u00eas linhas individuais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9 montado com uma cantoneira de alum\u00ednio de 30 x 30 mm, que \u00e9 fixada horizontalmente com fita adesiva de dupla face. <a href=\"https:\/\/www.amazon.de\/dp\/B086RQZYTM?psc=1&amp;ref=ppx_yo2ov_dt_b_product_details\" target=\"_blank\" rel=\"noopener\">Fita adesiva<\/a> \u00e9 colado no interior da parede. As ventoinhas tamb\u00e9m s\u00e3o fixadas da mesma forma. A fita adesiva grossa desacopla em grande parte os ru\u00eddos de funcionamento, embora, infelizmente, n\u00e3o completamente.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"308\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/Ventilatoren_KS-2.jpg\" alt=\"\" class=\"wp-image-5037\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/Ventilatoren_KS-2.jpg 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/Ventilatoren_KS-2-300x116.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/Ventilatoren_KS-2-768x296.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Lufter-Regelung\"><\/span>Controlo do ventilador<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bem, se a sa\u00edda n\u00e3o puder ser controlada atrav\u00e9s da velocidade, ent\u00e3o activando uma, duas ou todas as tr\u00eas ventoinhas, dependendo da diferen\u00e7a de temperatura antes do condensador e depois do evaporador.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">UM <a href=\"https:\/\/de.elv.com\/homematic-differenz-temperatur-sensor-hm-wds30-ot2-sm-2-fuer-smart-home-hausautomation-143420\" target=\"_blank\" rel=\"noopener\">Sensor de diferen\u00e7a de temperatura homem\u00e1tico<\/a> (sensor 1 fixado na parte superior do condensador com uma bra\u00e7adeira, sensor 2 fixado no tubo inferior ap\u00f3s o evaporador), determina os valores necess\u00e1rios e \u00e9 tamb\u00e9m fixado num espa\u00e7o livre atr\u00e1s da abertura de ventila\u00e7\u00e3o inferior na parede da caravana ou autocaravana com fita adesiva de dupla face.<br>Se n\u00e3o quiser utilizar pilhas ou pilhas recarreg\u00e1veis (2x AA), mas preferir utilizar a fonte de alimenta\u00e7\u00e3o de bordo de 12 V CC, encontrar\u00e1 <a href=\"https:\/\/csiag.eu\/pt\/medicao-da-temperatura\/\" data-type=\"link\" data-id=\"https:\/\/csiag.eu\/temperatur-messung\/\">aqui<\/a> instru\u00e7\u00f5es sobre como integrar um conversor DCDC 12 V \/ 3,3 V no sensor de diferen\u00e7a de temperatura para este efeito.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um atuador de comuta\u00e7\u00e3o Homematic de 4 portas alimenta os tr\u00eas ventiladores individuais com 12V atrav\u00e9s dos canais 1, 2 e 3.<br><strong>Aten\u00e7\u00e3o<\/strong> - Existem diferentes vers\u00f5es do atuador de comuta\u00e7\u00e3o de 4 dobras: com o <a href=\"https:\/\/de.elv.com\/homematic-funk-schaltaktor-4-fach-hm-lc-sw4-wm-fuer-smart-home-hausautomation-099082?fs=240820572\" target=\"_blank\" rel=\"noopener\">Vers\u00e3o com rel\u00e9 mec\u00e2nico<\/a> pode escolher livremente a polaridade de comuta\u00e7\u00e3o (mais ou menos), enquanto que os puramente electr\u00f3nicos, que comutam atrav\u00e9s de um trans\u00edstor de comuta\u00e7\u00e3o, normalmente comutam menos, ou seja, todos os fios mais devem ser ligados diretamente ao mais, enquanto que os fios menos s\u00e3o ligados aos terminais de parafuso dos canais 1 ... 3 est\u00e3o ligados.<br>Este tamb\u00e9m pode ser montado da mesma forma.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Programmierung\"><\/span>programa\u00e7\u00e3o<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Por uma quest\u00e3o de simplicidade, \u00e9 criado um programa separado para cada ventilador, que liga o respetivo ventilador em fun\u00e7\u00e3o do limiar de diferen\u00e7a de temperatura, bem como para o processo de desativa\u00e7\u00e3o quando a temperatura desce abaixo do limiar de comuta\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"text-indent: 10px; wp-block-paragraph\">Eis um exemplo para o ventilador no canal 1:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" style=\"padding-left: 40px;\"><span class=\"ez-toc-section\" id=\"Legende\"><\/span>Legenda:<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><p class=\"text-indent: 10px;\" style=\"padding-left: 80px;\">KS_TDS_Diff_K3 -&gt; Nome* do canal 3 do sensor de diferen\u00e7a de temperatura <br>KS_Lft -&gt; criado <a href=\"https:\/\/csiag.eu\/pt\/variaveis-do-sistema-smarthome\/\">vari\u00e1vel<\/a>** (verdadeiro ou n\u00e3o verdadeiro)<br>KS_SW_Lft1_K1 -&gt; Nome* do canal 1 do atuador de comuta\u00e7\u00e3o<br>KS_SW_Lft2_K2 -&gt; Nome* do canal 2 do atuador de comuta\u00e7\u00e3o<br>KS_SW_Lft3_K3 -&gt; Nome* do canal 3 do atuador de comuta\u00e7\u00e3o<br>KS_SW_Lft4_K4 -&gt; Nome* do canal 4 do atuador de comuta\u00e7\u00e3o<\/p><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><p style=\"padding-left: 80px;\">* ser\u00e1 enviado para <a href=\"https:\/\/csiag.eu\/pt\/aprenda-dispositivos-domesticos-inteligentes\/\" data-type=\"post\" data-id=\"73\">Treinamento<\/a> do dispositivo manualmente<br>** Uma vari\u00e1vel a ser verificada \u00e9 utilizada para decidir se uma a\u00e7\u00e3o subsequente <br>&nbsp; &nbsp; \u00e9 iniciado ou n\u00e3o.<br>&nbsp; &nbsp; (Aqui, por exemplo, a ventoinha n\u00e3o deve ser activada \u00e0 noite como ru\u00eddo de fundo. <br>&nbsp; &nbsp; &nbsp;Consequentemente, num programa separado, a vari\u00e1vel no per\u00edodo noturno \u00e9 definida para <br>&nbsp; &nbsp; &nbsp;\"n\u00e3o verdadeiro\", definido como \"verdadeiro\" durante o dia)<\/p><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ligar<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"324\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-6-1024x324.png\" alt=\"\" class=\"wp-image-5029\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-6-1024x324.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-6-1536x485.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-6-300x95.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-6-768x243.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-6.png 1924w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">O ventilador 2 liga-se quando \u00e9 ultrapassada uma temperatura diferencial* de 16 \u00b0C, o ventilador 3 a partir de 24 \u00b0C.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Desligar<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"358\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-7-1024x358.png\" alt=\"\" class=\"wp-image-5030\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-7-1024x358.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-7-1536x538.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-7-300x105.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-7-768x269.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-7.png 1926w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">O ventilador 2 desliga-se quando a temperatura diferencial* desce abaixo dos 8 \u00b0C, o ventilador 3 a partir dos 16 \u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uma vari\u00e1vel <code>SV_KS_Lft<\/code> pode ser utilizado para decidir se permite ou impede o funcionamento das ventoinhas em geral, por exemplo, se for sens\u00edvel ao ru\u00eddo noturno e, por isso, n\u00e3o quiser que as ventoinhas funcionem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*A temperatura diferencial \u00e9 aqui fixada arbitrariamente nos valores mencionados a t\u00edtulo de exemplo. Na realidade, a temperaturas exteriores de cerca de 5 ... 10 \u00b0C, a diferen\u00e7a de temperatura deve ser determinada sem ventila\u00e7\u00e3o ativa. \u00c0 medida que a temperatura exterior aumenta, a altera\u00e7\u00e3o desta diferen\u00e7a de temperatura \u00e9 monitorizada e o ponto de funcionamento dos ventiladores \u00e9 ajustado em conformidade.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Controlo manual<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"328\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-8-1024x328.png\" alt=\"\" class=\"wp-image-5031\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-8-1024x328.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-8-1536x492.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-8-300x96.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-8-768x246.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-8.png 1924w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Controlo manual e dependente do tempo<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"399\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-9-1024x399.png\" alt=\"\" class=\"wp-image-5032\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-9-1024x399.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-9-1536x599.png 1536w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-9-300x117.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-9-768x299.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/08\/image-9.png 1924w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Aqui, ou a vari\u00e1vel \u00e9 definida manualmente como \"falso\" para desligar todos os ventiladores ou automaticamente, dependendo do per\u00edodo de tempo selecionado, neste caso das 22:00 \u00e0s 07:00 todos os dias.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Temperatursensor_im_Gefrierfach\"><\/span>Sensor de temperatura no compartimento do congelador<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Se quiser jogar pelo seguro e fazer com que a a\u00e7\u00e3o da ventoinha dependa da temperatura no compartimento do congelador, fa\u00e7a um furo de cerca de 5 mm (di\u00e2metro do sensor de temperatura) no canto superior esquerdo do permutador de calor no compartimento do congelador, insira o sensor de temperatura neste furo por tr\u00e1s, empurre-o para a frente de modo a que apare\u00e7a no interior do compartimento do congelador com o seu al\u00edvio de tens\u00e3o do cabo e sele o furo e o cabo com silicone por tr\u00e1s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O sensor de temperatura pode ser do tipo <a href=\"https:\/\/www.eq-3.de\/produkte\/homematic\/detail\/hm-wds30-t-o.html\" target=\"_blank\" rel=\"noreferrer noopener\">HM-WDS30-T-O<\/a> (1 canal) ou <a href=\"https:\/\/de.elv.com\/homematic-differenz-temperatur-sensor-hm-wds30-ot2-sm-2-fuer-smart-home-hausautomation-143420\" target=\"_blank\" rel=\"noreferrer noopener\">HM-WDS30-OT2-SM-2<\/a> (2 canais).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Neste caso, a programa\u00e7\u00e3o n\u00e3o \u00e9 efectuada atrav\u00e9s do canal de diferen\u00e7as (<em>K3<\/em>), mas o canal do sensor associado (para o sensor de canal \u00fanico <em>K1<\/em>) ligando uma ventoinha quando a temperatura medida desce abaixo de -18 \u00b0C, por exemplo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O segundo ventilador \u00e9 ativado quando a temperatura atinge -16 \u00b0C, por exemplo, e o terceiro ventilador quando atinge -14 \u00b0C. Desta forma, a temperatura desejada (aqui, por exemplo, -20 \u00b0C) pode ser atingida de novo muito rapidamente, especialmente quando a temperatura exterior \u00e9 elevada.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 5<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>Com os frigor\u00edficos de absor\u00e7\u00e3o, em particular, \u00e9 um problema obter a capacidade de refrigera\u00e7\u00e3o necess\u00e1ria do frigor\u00edfico nas esta\u00e7\u00f5es quentes, especialmente nos climas mais a sul e, por conseguinte, mais quentes. Um controlo da ventoinha pode ser uma solu\u00e7\u00e3o. A diferen\u00e7a entre com e sem ventilador \u00e9 clara: sem ventilador, a temperatura no compartimento do congelador situa-se entre 7 ... 11 \u00b0C, com uma ventoinha, ap\u00f3s um curto per\u00edodo de tempo...&nbsp;<a href=\"https:\/\/csiag.eu\/pt\/blog\/2023\/08\/30\/kuehlschrank-ventilator-steuerung\/\" rel=\"bookmark\">Ler mais \"<span class=\"screen-reader-text\">Geladeira \u2013 Controle do Ventilador<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"off","neve_meta_content_width":70,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2106,346],"tags":[],"class_list":["post-5028","post","type-post","status-publish","format-standard","hentry","category-absorber-kuehlschrank","category-smarthome"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/5028","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/comments?post=5028"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/5028\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/media?parent=5028"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/categories?post=5028"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/tags?post=5028"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}