{"id":7018,"date":"2024-03-28T20:20:40","date_gmt":"2024-03-28T20:20:40","guid":{"rendered":"https:\/\/csiag.eu\/?p=7018"},"modified":"2024-03-31T08:44:49","modified_gmt":"2024-03-31T08:44:49","slug":"victron-ve-configure-3","status":"publish","type":"post","link":"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/","title":{"rendered":"Victron \u2013 VE Configurar 3"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Treiber-Installation\" >Instala\u00e7\u00e3o do controlador<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#COM-Port_Verbinden\" >Ligar a porta COM<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Einstellmoglichkeiten\" >Op\u00e7\u00f5es de defini\u00e7\u00e3o<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Multiplus_%E2%80%93_Status\" >Multiplus - Estado<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_General\" >Separador - Geral<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Grid\" >Separador - Grelha<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Inverter\" >Separador - Inversor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Charger\" >Separador - Carregador<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Virtual_Switch\" >Separador - Comutador virtual<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Assistant_Configuration\" >Separador - Configura\u00e7\u00e3o do Assistente<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Assistant_Tools\" >Separador - Ferramentas do Assistente<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Tab_%E2%80%93_Advanced\" >Separador - Avan\u00e7ado<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/#Victron_Toolkit\" >Kit de ferramentas Victron<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 6<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>\n<p>A Victron fornece o seguinte para programar o <em>Victron Multiplus II<\/em> o software Windows<em> VE Configurar 3<\/em> para o <a href=\"https:\/\/www.victronenergy.de\/Executables\/VEConfig\/VECSetup_B.exe\" target=\"_blank\" rel=\"noreferrer noopener\">Download<\/a> dispon\u00edvel,<\/p>\n\n\n\n<p>O software tamb\u00e9m funciona em <em>MAC OS<\/em> via <em>Paralelos<\/em> e instalado nele <em>Windows 11<\/em>.<\/p>\n\n\n\n<p>O software suporta o <a href=\"https:\/\/www.victronenergy.com\/accessories\/interface-mk3-usb\" target=\"_blank\" rel=\"noreferrer noopener\">MK3 VE.Bus para USB<\/a> que \u00e9 ligado atrav\u00e9s de um cabo RJ45 ao <em>Multiplus II<\/em> e o cabo USB para o computador.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Treiber-Installation\"><\/span>Instala\u00e7\u00e3o do controlador<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Fora de <em>Windows 11<\/em> o software acima mencionado \u00e9 descarregado do s\u00edtio Web da Victron e instalado.<\/p>\n\n\n\n<p>Numa segunda etapa, o software \u00e9 instalado e iniciado no item de menu <em>Esp\u00e9cie<\/em>l - <em>Controladores USB<\/em> o controlador USB atual \u00e9 recuperado e guardado num diret\u00f3rio \u00e0 sua escolha.<\/p>\n\n\n\n<p>A instala\u00e7\u00e3o do controlador no Windows \u00e9 normalmente um pouco indisciplinada:<br>Depois de ligar o <em>MK3<\/em> sobre <em>Multiplus II<\/em> e o computador, o Windows reconhece um novo dispositivo no gestor de dispositivos e pede o controlador. Pode esquecer a pesquisa autom\u00e1tica, pois o Windows continuar\u00e1 a n\u00e3o encontrar os controladores dispon\u00edveis no disco r\u00edgido devido \u00e0 falta de uma pesquisa recursiva.<\/p>\n\n\n\n<p>Dependendo do chipset (AMD64 \/ i386) do computador, o driver previamente guardado deve ser instalado no diret\u00f3rio de instala\u00e7\u00e3o correspondente. <kbd>...\/Drivers USB\/MK2_MK3_USB\/ ARM64<\/kbd> ou <kbd>...\/USBDrivers\/MK2_MK3_USB\/x86<\/kbd>ou para processadores ARM <kbd>...\/USBDrivers\/MK2_MK3_USB para ARM\/ARM64<\/kbd> ou <kbd>...\/USBDrivers\/MK2_MK3_USB para ARM\/x86<\/kbd> ser procurado e instalado.<\/p>\n\n\n\n<p>O Windows reconhece agora um novo dispositivo e uma porta COM, mas falta o controlador. Procedimento id\u00eantico ao anterior, percorrer as diretorias at\u00e9 o Windows reconhecer e instalar o controlador da porta COM a partir de uma das diretorias acima mencionadas.<\/p>\n\n\n\n<p>Agora j\u00e1 n\u00e3o deve haver nenhum controlador em falta no gestor de dispositivos e <em>VE Configurar 3<\/em> pode ser iniciado.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"626\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_connect.png\" alt=\"\" class=\"wp-image-7020\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_connect.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_connect-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_connect-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_connect-768x601.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Ecr\u00e3 inicial VE Configurar 3<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"COM-Port_Verbinden\"><\/span>Ligar a porta COM<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Sob o item de menu <em>Sele\u00e7\u00e3o do porto<\/em> sob o primeiro item de menu est\u00e1 o subitem <em>Dete\u00e7\u00e3o autom\u00e1tica<\/em> (n\u00e3o para MK1), e (por exemplo) <em>Porta COM 3<\/em>desde que a instala\u00e7\u00e3o do controlador tenha sido completamente bem sucedida.<\/p>\n\n\n\n<p>Clique em <em>Porta Com 3<\/em> estabelece a liga\u00e7\u00e3o entre o computador e o Multiplus II, carrega os dados actuais e apresenta-os no VE Configure 3.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_reading.png\" alt=\"\" class=\"wp-image-7021\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_reading.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_reading-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_reading-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_reading-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Liga\u00e7\u00e3o estabelecida - os dados s\u00e3o lidos<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Einstellmoglichkeiten\"><\/span>Op\u00e7\u00f5es de defini\u00e7\u00e3o<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>O seguinte aplica-se a todos os separadores: cada altera\u00e7\u00e3o \u00e9 destacada a cores e deve ser efectuada antes de alterar um separador, clicando no bot\u00e3o no canto inferior esquerdo. <em>Defini\u00e7\u00f5es de envio<\/em> podem ser guardadas. Uma vez guardadas as altera\u00e7\u00f5es, as informa\u00e7\u00f5es voltam a ser apresentadas a preto.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"594\" height=\"306\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Sending.png\" alt=\"\" class=\"wp-image-7054\" style=\"width:338px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Sending.png 594w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Sending-18x9.png 18w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Sending-300x155.png 300w\" sizes=\"(max-width: 594px) 100vw, 594px\" \/><figcaption class=\"wp-element-caption\">Alterado Guardar dados<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Se quiser testar se as altera\u00e7\u00f5es foram efetivamente escritas, pode clicar no bot\u00e3o acima <em>Obter defini\u00e7\u00f5es<\/em> a mem\u00f3ria pode ser lida e os valores verificados.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Multiplus_%E2%80%93_Status\"><\/span>Multiplus - Estado<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A janela de estado <em>Multiplus II <\/em>no canto superior esquerdo mostra os par\u00e2metros de entrada e sa\u00edda actuais e \u00e9 mantido em cada vista de separador. Ao clicar no bot\u00e3o <em>show VE.Bus monitor<\/em> resulta numa vista separada.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"868\" height=\"870\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_BusMonitor.png\" alt=\"\" class=\"wp-image-7056\" style=\"width:557px;height:auto\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_BusMonitor.png 868w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_BusMonitor-12x12.png 12w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_BusMonitor-150x150.png 150w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_BusMonitor-300x300.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_BusMonitor-768x770.png 768w\" sizes=\"(max-width: 868px) 100vw, 868px\" \/><figcaption class=\"wp-element-caption\">VE.Janela de estado do monitor de bus<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_General\"><\/span>Separador - Geral<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Para al\u00e9m da sele\u00e7\u00e3o da frequ\u00eancia 50 \/ 60 Hz, pode ser definida a corrente m\u00e1xima permitida no lado da entrada. Se este valor pode ser ajustado por controlo remoto depende da ativa\u00e7\u00e3o da caixa de verifica\u00e7\u00e3o <em>Anula\u00e7\u00e3o por controlo remoto<\/em> de.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Limite de corrente de entrada AC<\/em><\/li>\n<\/ul>\n\n\n\n<p>No funcionamento do gerador, este valor limita o consumo de energia m\u00e1ximo poss\u00edvel do Multiplus Charger, de forma a proteger o gerador de sobrecarga. Um valor recomendado \u00e9 inferior a 80 por cento da pot\u00eancia do gerador dividida pela tens\u00e3o. <\/p>\n\n\n\n<p><kbd>Exemplo<\/kbd>:<\/p>\n\n\n\n<p>Pot\u00eancia nominal do gerador 4.000 W, dos quais o 80% corresponde a 3.200 W, divididos por 230 V = 13,9 A.<br>Daqui resulta <em>13<\/em> A como o valor a introduzir.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Limitador de corrente din\u00e2mico<\/em> - Esta fun\u00e7\u00e3o tem em conta o momento de in\u00e9rcia dos geradores com inversor, como a s\u00e9rie Honda EU, ao ligar cargas maiores.<\/li>\n\n\n\n<li><em>Sensor de corrente externo<\/em> tem de ser ativado se estiver ligado um sensor de corrente externo ao Multiplus II.<\/li>\n\n\n\n<li><em>Ativar o monitor da bateria<\/em> representa a avalia\u00e7\u00e3o, do lado do sistema, dos dados das baterias dos sistemas internos de baterias, se activados.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_General.png\" alt=\"\" class=\"wp-image-7022\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_General.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_General-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_General-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_General-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Geral - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Grid\"><\/span>Separador - Grelha<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Pa\u00eds \/ c\u00f3digo de grelha padr\u00e3o<\/em> define as defini\u00e7\u00f5es espec\u00edficas do pa\u00eds se pretender alimentar a rede p\u00fablica. Caso contr\u00e1rio, como mostrado aqui, n\u00e3o \u00e9 feita qualquer sele\u00e7\u00e3o.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Interruptor de transfer\u00eancia<\/em> As predefini\u00e7\u00f5es determinam quando o dispositivo se desliga ou volta a ligar-se \u00e0 rede el\u00e9ctrica. As predefini\u00e7\u00f5es s\u00f3 devem ser alteradas em constela\u00e7\u00f5es espec\u00edficas.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Fun\u00e7\u00e3o UPS<\/em> Quando ligado \u00e0 rede p\u00fablica, garante o fornecimento ininterrupto de energia \u00e0s cargas ligadas em caso de falha da rede.<br>Quando utilizada como solu\u00e7\u00e3o aut\u00f3noma, esta fun\u00e7\u00e3o deve ser desligada, uma vez que as baterias devem poder ser carregadas mesmo que a qualidade da alimenta\u00e7\u00e3o el\u00e9ctrica, por exemplo, atrav\u00e9s de um gerador, n\u00e3o satisfa\u00e7a as condi\u00e7\u00f5es ideais.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Grid.png\" alt=\"\" class=\"wp-image-7023\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Grid.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Grid-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Grid-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Grid-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Grelha - Defini\u00e7\u00e3o<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Inverter\"><\/span>Separador - Inversor<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Rel\u00e9 de terra<\/em> ativo significa que a sa\u00edda do inversor L2 est\u00e1 desactivada para os modelos de 120 \/ 230 V (fase dividida).<br>Se estiver instalado um RCD na instala\u00e7\u00e3o, o rel\u00e9 de liga\u00e7\u00e3o \u00e0 terra deve ser ativado. Quando o comutador interno est\u00e1 aberto e o dispositivo \u00e9 operado no modo de inversor, o condutor neutro (N) do inversor \u00e9 ligado a PE. Se o comutador interno se fechar, a entrada CA \u00e9 transferida para a sa\u00edda e N \u00e9 desligado de PE.<\/li>\n\n\n\n<li><em>Desligamento baixo da entrada CC<\/em> protege a bateria de uma descarga profunda e deve ser introduzido de acordo com as instru\u00e7\u00f5es do fabricante.<\/li>\n\n\n\n<li><em>Rein\u00edcio do n\u00edvel de entrada DC<\/em> \/ <em>Pr\u00e9-alarme de entrada DC baixa<\/em> s\u00e3o par\u00e2metros interdependentes: qualquer que seja o par\u00e2metro alterado, o outro segue-se da mesma forma.<br>O valor deve ser sempre pelo menos 1 volt acima do valor <em>Desligamento baixo da entrada DC<\/em> mentira.<\/li>\n\n\n\n<li><em>N\u00e3o reiniciar ap\u00f3s um curto-circuito <\/em>impede que o dispositivo seja reiniciado quando \u00e9 detectado um evento de curto-circuito, enquanto outras condi\u00e7\u00f5es de sobrecarga permitem um rein\u00edcio ap\u00f3s terem diminu\u00eddo.<\/li>\n\n\n\n<li><em>ativar AES<\/em> conduz a um arranque suave para consumidores com uma carga elevada. No caso de micro-ondas, fornos de ar quente ou sistemas de ar condicionado, por exemplo, isto leva a um comportamento de sobrecarga e deve permanecer desativado.<\/li>\n\n\n\n<li><em>PowerAssist<\/em> fornece corrente adicional atrav\u00e9s do inversor \u00e0 custa das baterias, de modo a evitar que o fus\u00edvel CA do lado da entrada dispare e para fornecer a maior necessidade de corrente do consumidor.<\/li>\n\n\n\n<li><em>Auxiliar o fator de arranque atual<\/em> representa a pot\u00eancia m\u00e1xima necess\u00e1ria fornecida pelo inversor. O valor predefinido <em>2<\/em> cumpre os requisitos habituais de funcionamento e \u00e9 considerado seguro. Uma altera\u00e7\u00e3o s\u00f3 deve ser efectuada se as consequ\u00eancias forem conhecidas e classificadas como seguras para operar.<\/li>\n\n\n\n<li><em>encerramento no SOC<\/em> permite um encerramento dependente do SOC ao utilizar baterias do sistema Victron se um crit\u00e9rio dependente da tens\u00e3o for considerado demasiado inseguro. Os valores devem ser introduzidos numa base espec\u00edfica do fabricante.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Inverter.png\" alt=\"\" class=\"wp-image-7024\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Inverter.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Inverter-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Inverter-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Inverter-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Inversor - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Charger\"><\/span>Separador - Carregador<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Ativar o carregador<\/em> ativa ou desactiva a fun\u00e7\u00e3o de carregamento.<\/li>\n\n\n\n<li><em>Entrada CA fraca<\/em> \u00e9 uma fun\u00e7\u00e3o destinada a melhorar o comportamento do carregamento com fontes de tens\u00e3o n\u00e3o normalizadas (desvios do cos \u03d5), como os geradores, uma vez que mant\u00e9m o cos \u03d5 dentro de limites aceit\u00e1veis.<\/li>\n\n\n\n<li><em>Parar ap\u00f3s um volume excessivo<\/em> \u00e9 uma prote\u00e7\u00e3o contra sobrecarga que cancela o processo de carregamento se a tens\u00e3o de absor\u00e7\u00e3o n\u00e3o for atingida ap\u00f3s dez horas.<\/li>\n\n\n\n<li><em>Bateria de l\u00edtio<\/em> \u00e9 utilizado para introduzir par\u00e2metros espec\u00edficos da bateria de acordo com as especifica\u00e7\u00f5es do fabricante.<\/li>\n\n\n\n<li><em>Curva de carga<\/em> deve <em>Adaptativo<\/em> ser. S\u00f3 nos casos em que a rela\u00e7\u00e3o entre o processo de carregamento e as baterias utilizadas n\u00e3o esteja em harmonia \u00e9 que <em>Fixo<\/em> deve ser selecionada. Desta forma, evita-se que a tens\u00e3o de carga suba demasiado depressa ou demasiado devagar e que a bateria seja sobrecarregada ou insuficientemente carregada.<\/li>\n\n\n\n<li><em>Parar a carga abaixo<\/em> determina a temperatura a partir da qual o carregamento \u00e9 interrompido. As baterias de l\u00edtio n\u00e3o devem ser carregadas abaixo de 0 \u00b0C, exceto se forem aquecidas.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"803\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Charger-1024x803.png\" alt=\"\" class=\"wp-image-7052\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Charger-1024x803.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Charger-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Charger-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Charger-768x602.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Charger.png 1260w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Carregador - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Virtual_Switch\"><\/span>Separador - Comutador virtual<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p><em>Especificar a utiliza\u00e7\u00e3o do comutador virtual<\/em> define a utiliza\u00e7\u00e3o dos dois rel\u00e9s integrados em fun\u00e7\u00e3o de crit\u00e9rios ajust\u00e1veis. Uma descri\u00e7\u00e3o pormenorizada \u00e9 fornecida pela Victron <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/VEConfigure_Manual\/en\/virtual-switch.html\" target=\"_blank\" rel=\"noreferrer noopener\">aqui<\/a> dispon\u00edvel.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Vitrtual_Switch.png\" alt=\"\" class=\"wp-image-7027\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Vitrtual_Switch.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Vitrtual_Switch-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Vitrtual_Switch-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Vitrtual_Switch-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Comutador virtual - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Assistant_Configuration\"><\/span>Separador - Configura\u00e7\u00e3o do Assistente<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Os assistentes s\u00e3o aplica\u00e7\u00f5es no firmware que podem ser activadas conforme necess\u00e1rio atrav\u00e9s do <em>Adicionar assistente<\/em> podem ser activados. Entre outras coisas, podem ser utilizados para arrancar ou desligar automaticamente um gerador, dependendo da carga do sistema e do estado de carga da bateria.<\/p>\n\n\n\n<p>Cada assistente adicionado deve ser confirmado clicando no bot\u00e3o <em>Assistente inicial<\/em> ser ativado. O texto informativo seguinte cont\u00e9m informa\u00e7\u00f5es importantes e pr\u00e9-requisitos para a utiliza\u00e7\u00e3o correta do assistente, que devem ser respeitados.<\/p>\n\n\n\n<p>Alguns assistentes requerem entradas de valores adicionais para funcionarem corretamente ou dependem de assistentes previamente instalados. As instru\u00e7\u00f5es relativas \u00e0 sequ\u00eancia e \u00e0s depend\u00eancias m\u00fatuas devem ser seguidas.<\/p>\n\n\n\n<p>Uma vez efectuadas todas as entradas, os dados s\u00e3o escritos ap\u00f3s a consulta sobre se a configura\u00e7\u00e3o deve ser guardada, juntamente com a informa\u00e7\u00e3o de que o sistema ser\u00e1 desligado durante o processo de grava\u00e7\u00e3o, clicando no bot\u00e3o <em>Sim<\/em>.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistants_Config.png\" alt=\"\" class=\"wp-image-7026\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistants_Config.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistants_Config-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistants_Config-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistants_Config-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Configura\u00e7\u00e3o do Assistente - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Assistant_Tools\"><\/span>Separador - Ferramentas do Assistente<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>S\u00e3o utilizados para manuten\u00e7\u00e3o, como actualiza\u00e7\u00f5es de assistentes, repara\u00e7\u00e3o de instala\u00e7\u00f5es de assistentes danificadas ou gest\u00e3o de assistentes criados pelo pr\u00f3prio. Os erros podem ser apresentados e as causas localizadas atrav\u00e9s de relat\u00f3rios de erros.<\/p>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistant_Tools.png\" alt=\"\" class=\"wp-image-7028\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistant_Tools.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistant_Tools-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistant_Tools-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Assistant_Tools-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Ferramentas do Assistente VE - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tab_%E2%80%93_Advanced\"><\/span>Separador - Avan\u00e7ado<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Limitar o carregador interno para dar prioridade a outras fontes de energia<\/em> permite conservar as baterias quando est\u00e3o dispon\u00edveis outras fontes de energia, por exemplo, o rendimento de um sistema fotovoltaico ou e\u00f3lico, que t\u00eam ent\u00e3o prioridade.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"627\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Advanced.png\" alt=\"\" class=\"wp-image-7029\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Advanced.png 800w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Advanced-15x12.png 15w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Advanced-300x235.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2024\/03\/VE_Advanced-768x602.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">VE Avan\u00e7ado - Defini\u00e7\u00f5es<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Victron_Toolkit\"><\/span>Kit de ferramentas Victron<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><em>Kit de ferramentas Victron<\/em> \u00e9 uma aplica\u00e7\u00e3o para iOS e Android que fornece uma calculadora da sec\u00e7\u00e3o transversal do cabo, uma representa\u00e7\u00e3o num\u00e9rica e gr\u00e1fica da rela\u00e7\u00e3o entre temperatura e corrente ou pot\u00eancia de sa\u00edda e uma vis\u00e3o geral do significado dos indicadores de estado LED para todos os produtos victron.<\/p>\n\n\n\n<p>Esta \u00faltima carater\u00edstica, em particular, \u00e9 \u00fatil em situa\u00e7\u00f5es de erro, especialmente porque \u00e9 dif\u00edcil recordar todas as indica\u00e7\u00f5es de estado e o seu significado.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Tempo de leitura<\/span> <span class=\"rt-time\"> 6<\/span> <span class=\"rt-label rt-postfix\">minutos<\/span><\/span>A Victron fornece o software Windows VE Configure 3 para download para programar o Victron Multiplus II. O software tamb\u00e9m funciona no MAC OS atrav\u00e9s do Parallels e do Windows 11 instalado. O software suporta o conversor MK3 VE.Bus para USB, que \u00e9 ligado ao Multiplus II atrav\u00e9s do cabo RJ45 e do cabo USB ao computador. Instala\u00e7\u00e3o do controlador A partir do Windows...&nbsp;<a href=\"https:\/\/csiag.eu\/pt\/blog\/2024\/03\/28\/victron-ve-configure-3\/\" rel=\"bookmark\">Ler mais \"<span class=\"screen-reader-text\">Victron \u2013 VE Configurar 3<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1757,3197,1260],"tags":[3206,2078,3205,1295,3200,3202,3203,1289,3204,2309,3208,3201,3198,3207,519,2065,3199],"class_list":["post-7018","post","type-post","status-publish","format-standard","hentry","category-elektrotechnik","category-inverter","category-stromerzeugung","tag-com-port","tag-download","tag-geraetemanager","tag-inverter","tag-mac-osx","tag-mk3","tag-mk3-ve-bus-zu-usb","tag-multiplus-ii-2","tag-rj45","tag-status","tag-toolkit","tag-usb-treiber","tag-ve-configure","tag-ve-bus-monitor","tag-victron","tag-windows","tag-windows-11"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/7018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/comments?post=7018"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/posts\/7018\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/media?parent=7018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/categories?post=7018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/pt\/wp-json\/wp\/v2\/tags?post=7018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}