{"id":10113,"date":"2025-06-21T16:36:59","date_gmt":"2025-06-21T16:36:59","guid":{"rendered":"https:\/\/csiag.eu\/?p=10113"},"modified":"2025-10-06T19:18:30","modified_gmt":"2025-10-06T19:18:30","slug":"spinanie-230v-zdroja-v-obytnom-automobile","status":"publish","type":"post","link":"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/","title":{"rendered":"Sp\u00ednanie 230V zdroja v karavane"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Obsah<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#230_V_Quellen\" >230 V zdroje<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Netz-Vorrangschaltung\" >Sie\u0165ov\u00fd prioritn\u00fd obvod<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Nulldurchgang\" >Nulov\u00fd prechod<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Neutral-_N_und_Null-Leiter_PEN\" >Neutr\u00e1lny vodi\u010d (N) a neutr\u00e1lny vodi\u010d (PEN)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Die_Alternative\" >Alternat\u00edva<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Praxis-Beispiel\" >Praktick\u00fd pr\u00edklad<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Materialien\" >Materi\u00e1ly<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Landstrom_angeschlossen\" >Pripojen\u00e9 pobre\u017en\u00e9 nap\u00e1janie<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Landstrom_abgeschaltet_%E2%80%93_Wechselrichter-Versorgung\" >Vypnut\u00e9 pobre\u017en\u00e9 nap\u00e1janie - nap\u00e1janie z meni\u010da<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Landstrom_abgeschaltet_%E2%80%93_Generator-Einsatz\" >Vypnut\u00e9 pobre\u017en\u00e9 nap\u00e1janie - pou\u017eitie gener\u00e1tora<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Landstrom_eingeschaltet\" >Zapnut\u00e9 pobre\u017en\u00e9 nap\u00e1janie<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Automatisierter_Generator-Stop\" >Automatick\u00e9 zastavenie gener\u00e1tora<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#Hinweis\" >N\u00e1poveda<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/#%E2%80%93_Achtung_%E2%80%93\" >- Pozor -<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">\u010cas \u010d\u00edtania<\/span> <span class=\"rt-time\"> 5<\/span> <span class=\"rt-label rt-postfix\">z\u00e1pisnice<\/span><\/span>\n<p>Mo\u017eno sa najprv p\u00fdtate, pre\u010do automaticky prep\u00edna\u0165 zdroj 230 V v karavane. Ak sa v\u0161ak sna\u017e\u00edte o ur\u010dit\u00fd stupe\u0148 energetickej sebesta\u010dnosti, m\u00e1te k dispoz\u00edcii aj nieko\u013eko mo\u017enost\u00ed nap\u00e1jania spotrebi\u010dov striedav\u00e9ho pr\u00fadu a prep\u00ednania medzi nimi pod\u013ea potreby.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"230_V_Quellen\"><\/span>230 V zdroje<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Norm\u00e1lne nap\u00e1janie striedav\u00fdm nap\u00e4t\u00edm (AC - <em>striedav\u00fd pr\u00fad<\/em>) je nap\u00e1jan\u00fd z pobre\u017enej elektrickej siete, samozrejme, za predpokladu, \u017ee je k dispoz\u00edcii. Na cest\u00e1ch s\u00fa \u010fal\u0161ie dve mo\u017enosti: nap\u00e1janie cez vlastn\u00fd meni\u010d alebo cez zabudovan\u00fd (plynov\u00fd) gener\u00e1tor.<\/p>\n\n\n\n<p>Ke\u010f\u017ee len ve\u013emi m\u00e1lo gener\u00e1torov je ur\u010den\u00fdch na nap\u00e1janie meni\u010da a je potrebn\u00e9 zabezpe\u010di\u0165, aby sa gener\u00e1tor alebo meni\u010d nemohol ne\u00famyselne zapn\u00fa\u0165, ke\u010f je pripojen\u00e9 pobre\u017en\u00e9 nap\u00e1janie, bolo by u\u017eito\u010dn\u00e9 zablokova\u0165 tri mo\u017en\u00e9 zdroje nap\u00e1jania, aby nemohlo d\u00f4js\u0165 k paralelnej prev\u00e1dzke.<br>Samozrejme, to plat\u00ed aj pre pripojenie nap\u00e4tia z gener\u00e1tora alebo meni\u010da do externej z\u00e1suvky pre pr\u00edvod elektrickej energie z brehu!<\/p>\n\n\n\n<p>Vybran\u00fd zdroj energie by sa mal automaticky pripoji\u0165 k spotrebite\u013eom, t. j. k sieti obytn\u00fdch automobilov.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Netz-Vorrangschaltung\"><\/span>Sie\u0165ov\u00fd prioritn\u00fd obvod<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Elektronick\u00e9 prioritn\u00e9 sie\u0165ov\u00e9 obvody maj\u00fa zvy\u010dajne t\u00fa nev\u00fdhodu, \u017ee zvl\u00e1dnu len pribli\u017ene 1 600 ... 2 000 W, preto sa tu nem\u00f4\u017eu pou\u017ei\u0165, hoci ich v\u00fdhodou je sp\u00ednanie v nulovom bode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Nulldurchgang\"><\/span>Nulov\u00fd prechod<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Prechod nulou opisuje okamih, v ktorom sa s\u00ednusoida striedav\u00e9ho nap\u00e4tia zmen\u00ed na kladn\u00fa alebo z\u00e1porn\u00fa polvlnu, t. j. dvakr\u00e1t za s\u00ednusoidu alebo pri sie\u0165ovej frekvencii 50 Hz 100-kr\u00e1t za sekundu alebo ka\u017ed\u00fdch 10 ms.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"472\" height=\"295\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Sinus_Welle.png\" alt=\"\" class=\"wp-image-10157\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Sinus_Welle.png 472w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Sinus_Welle-300x188.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Sinus_Welle-18x12.png 18w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><\/figure>\n<\/div>\n\n\n<p>V t\u00fdchto okamihoch je pr\u00fad nulov\u00fd, preto\u017ee aj nap\u00e4tie je nulov\u00e9, \u010do znamen\u00e1, \u017ee je mo\u017en\u00e9 sp\u00ednanie bez z\u00e1\u0165a\u017ee.<\/p>\n\n\n\n<p>Uhol zobrazen\u00fd na osi x predstavuje f\u00e1zov\u00fd posun od nulov\u00e9ho bodu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Neutral-_N_und_Null-Leiter_PEN\"><\/span>Neutr\u00e1lny vodi\u010d (N) a neutr\u00e1lny vodi\u010d (PEN)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p><strong>Mo\u017enos\u0165 z\u00e1meny<\/strong> pon\u00faka elektrotechnick\u00fdm laikom be\u017en\u00fd term\u00edn <em>Zero<\/em>-vodi\u010d, \u010dasto stoto\u017e\u0148ovan\u00fd s ozna\u010den\u00edm modr\u00e9ho vodi\u010da.<\/p>\n\n\n\n<p>Vodi\u010d ozna\u010den\u00fd modrou farbou v\u0161ak NIE JE <em>Zero<\/em>-vodca, ale <em>Neutr\u00e1lne<\/em>-vodi\u010d (N). T\u00fdmto vodi\u010dom te\u010die pr\u00fad sp\u00e4\u0165 do nulov\u00e9ho bodu troch cievok transform\u00e1tora dod\u00e1vate\u013ea elektrickej energie. Ke\u010f\u017ee sa nach\u00e1dza v \"strede\" troch cievok transform\u00e1tora, v ich neutr\u00e1lnom bode, naz\u00fdval sa aj \"neutr\u00e1lny bod\". <em>Stredn\u00e9<\/em>-rebr\u00edk.<\/p>\n\n\n\n<p>Vodi\u010d ozna\u010den\u00fd \u017eltozelenou farbou a laicky naz\u00fdvan\u00fd \"uzem\u0148ovac\u00ed\" vodi\u010d je spr\u00e1vne ozna\u010den\u00fd <em>Zero<\/em>-alebo <em>Ochrana<\/em>-Mana\u017e\u00e9r (<em>PEN<\/em> - <em>ochrann\u00e9 uzemnenie neutr\u00e1lne<\/em>) je ozna\u010den\u00fd.<br>Hoci sa n\u00e1zov \"nulov\u00fd\" vodi\u010d pou\u017e\u00edval a\u017e do roku 1991, u\u017e v roku 1973 sa zmenil na vodi\u010d PEN, \u010do je kombin\u00e1cia ozna\u010den\u00ed \"PE\" a \"N\".<\/p>\n\n\n\n<p>Na druhej strane, f\u00e1zy (L1, L2 a L3) sa \u010dasto rozpozn\u00e1vaj\u00fa spr\u00e1vne: \u010dierna, hned\u00e1 a siv\u00e1 farba predstavuj\u00fa jednu z troch f\u00e1z (naz\u00fdvan\u00fdch aj <em>Exteri\u00e9r<\/em>-vodi\u010de - preto\u017ee sa nach\u00e1dzaj\u00fa na vonkaj\u0161ej strane, na konci cievok transform\u00e1tora). Dod\u00e1vaj\u00fa pr\u00fad z troch cievok transform\u00e1tora do koncov\u00e9ho spotrebi\u010da.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"215\" height=\"213\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Stern_Schaltung.png\" alt=\"\" class=\"wp-image-10180\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Stern_Schaltung.png 215w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Stern_Schaltung-150x150.png 150w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/Stern_Schaltung-12x12.png 12w\" sizes=\"(max-width: 215px) 100vw, 215px\" \/><\/figure>\n<\/div>\n\n\n<p>Na tomto obr\u00e1zku je zn\u00e1zornen\u00e9 zapojenie troch cievok transform\u00e1tora do hviezdy: 230 V sa meria medzi ka\u017edou f\u00e1zou (Lx) a nulov\u00fdm bodom (N). Medzi ka\u017edou f\u00e1zou sa v\u0161ak meria 400 V bez nulov\u00e9ho bodu.<br>To vysvet\u013euje, pre\u010do sa nulov\u00fd vodi\u010d (N) nikdy nesmie odpoji\u0165 s \u010dasov\u00fdm rozdielom, preto\u017ee udr\u017eiava nap\u00e4tie troch f\u00e1z na spolo\u010dnej \u00farovni 230 V bez oh\u013eadu na za\u0165a\u017eenie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Die_Alternative\"><\/span>Alternat\u00edva<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Str\u00e1nka <em>ABB<\/em> St\u00fdka\u010d <em>ESB40-22N-06 <\/em>zvl\u00e1dne 9 200 W, \u010do zodpoved\u00e1 40 A, a preto by mal ma\u0165 dobr\u00fa \u017eivotnos\u0165 pre 16 A poistku, ktor\u00e1 sa zvy\u010dajne pou\u017e\u00edva v obytn\u00fdch vozidl\u00e1ch s viac ako dvojn\u00e1sobnou v\u00fdkonovou rezervou.<\/p>\n\n\n\n<p>Elektronick\u00e9 vysoko v\u00fdkonn\u00e9 rel\u00e9 (polovodi\u010dov\u00e9 rel\u00e9) <em>SSR<\/em> - Triakov\u00e9 obvody) s\u00fa vyl\u00fa\u010den\u00e9 z d\u00f4vodu vysok\u00e9ho v\u00fdvinu tepla a potrebn\u00e9ho, prinajmen\u0161om pas\u00edvneho chladenia - aj keby sa v\u017edy sp\u00ednali v nulovom bode, \u010do by bolo \u017eiaduce.<\/p>\n\n\n\n<p>Na ot\u00e1zku, \u010di je mo\u017en\u00e9 pou\u017ei\u0165 dve samostatn\u00e9 prep\u00ednacie rel\u00e9 na prep\u00ednanie nulov\u00e9ho vodi\u010da a f\u00e1zy, treba odpoveda\u0165 kategoricky NIE:<br>Nulov\u00fd vodi\u010d sa NIKDY nesmie pripoji\u0165 k f\u00e1ze v inom \u010dase, aby sa minimalizovalo riziko rozdielu za\u0165a\u017eenia f\u00e1z, <em>Nevyv\u00e1\u017een\u00e9 za\u0165a\u017eenie<\/em> a v\u00fdsledn\u00fd <em>Posun hviezdneho bodu<\/em> ktor\u00fdm sa treba vyhn\u00fa\u0165. Mohlo by to vies\u0165 k tomu, \u017ee z\u00e1\u0165a\u017e 230 V by bola nap\u00e1jan\u00e1 nap\u00e4t\u00edm a\u017e 400 V, a t\u00fdm by sa po\u0161kodila.<br>Preto MUSIA by\u0165 obidva vodi\u010de sp\u00ednan\u00e9 s\u00fa\u010dasne prostredn\u00edctvom (pozit\u00edvne riaden\u00e9ho st\u00fdka\u010da, a teda spo\u013eahlivo).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Praxis-Beispiel\"><\/span>Praktick\u00fd pr\u00edklad<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ale ako to cel\u00e9 prepoji\u0165?<\/p>\n\n\n\n<p>Na nasleduj\u00facej sch\u00e9me je zn\u00e1zornen\u00e9 zapojenie komponentov (bez nakreslen\u00e9ho PEN):<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"865\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_230V_Verteilung_Ruhezustand-1024x865.png\" alt=\"\" class=\"wp-image-11106\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_230V_Verteilung_Ruhezustand-1024x865.png 1024w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_230V_Verteilung_Ruhezustand-300x253.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_230V_Verteilung_Ruhezustand-768x649.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_230V_Verteilung_Ruhezustand-14x12.png 14w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_230V_Verteilung_Ruhezustand.png 1280w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Materialien\"><\/span>Materi\u00e1ly<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Existuj\u00fa dva kusy <em>ABB ESB40-22N-06<\/em> potrebn\u00e9.<\/p>\n\n\n\n<p>Je potrebn\u00e9 dodr\u017eiava\u0165 technick\u00e9 \u0161pecifik\u00e1cie. Ak s\u00fa v\u0161etky kontakty (norm\u00e1lne uzavret\u00e9 a norm\u00e1lne otvoren\u00e9) za\u0165a\u017een\u00e9 pr\u00fadom max. 30 A, je v\u0161etko v poriadku. Iba rozp\u00ednacie kontakty m\u00f4\u017eu by\u0165 za\u0165a\u017een\u00e9 pr\u00fadom a\u017e 40 A.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"853\" height=\"358\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_Schuetz_bestromte_Stellung.png\" alt=\"\" class=\"wp-image-11115\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_Schuetz_bestromte_Stellung.png 853w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_Schuetz_bestromte_Stellung-300x126.png 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_Schuetz_bestromte_Stellung-768x322.png 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2025\/06\/ABB_Schuetz_bestromte_Stellung-18x8.png 18w\" sizes=\"(max-width: 853px) 100vw, 853px\" \/><\/figure>\n<\/div>\n\n\n<p>Zapojenie by malo by\u0165 pripojen\u00e9 pomocou 2,5 mm<sup>2<\/sup> aby sa straty v k\u00e1bloch bl\u00ed\u017eili k nule. Pou\u017eitie koncoviek pre viac\u017eilov\u00e9 ohybn\u00e9 k\u00e1ble sa pova\u017euje za samozrejmos\u0165, ale tu sa v\u00fdslovne uv\u00e1dza.<\/p>\n\n\n\n<p>Hodnoty uveden\u00e9 vo vy\u0161\u0161ie uvedenom grafe s <em>S_Ext<\/em> a <em>S_Int<\/em> ur\u010den\u00ed kontakt\u00e9ri s\u00fa zodpovedn\u00ed za <em>extern\u00e9<\/em>alebo <em>vn\u00fatorn\u00e9<\/em> prep\u00ednanie nap\u00e4tia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Landstrom_angeschlossen\"><\/span>Pripojen\u00e9 pobre\u017en\u00e9 nap\u00e1janie<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>St\u00fdka\u010d <em>S_Ext<\/em> sp\u00edna pri pripojen\u00ed pobre\u017en\u00e9ho nap\u00e1jania a prip\u00e1ja nulu na svorky 4 a 3 alebo f\u00e1zu na svorky 5 a 6. T\u00fdm sa vytvor\u00ed nap\u00e1janie motorov\u00e9ho vozidla a meni\u010da (ktor\u00fd tak nab\u00edja pripojen\u00e9 bat\u00e9rie v re\u017eime nab\u00edjania).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Landstrom_abgeschaltet_%E2%80%93_Wechselrichter-Versorgung\"><\/span>Vypnut\u00e9 pobre\u017en\u00e9 nap\u00e1janie - nap\u00e1janie z meni\u010da<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ak sa odpoj\u00ed pobre\u017en\u00e1 elektrick\u00e1 pr\u00edpojka, st\u00fdka\u010d vypadne, odpoj\u00ed uveden\u00e9 pr\u00edpojky a namiesto toho vytvor\u00ed spojenie medzi pr\u00edpojkami 1 a 2 (neutr\u00e1l) a 7 a 8 (f\u00e1za), ktor\u00e9 s\u00fa pripojen\u00e9 k druh\u00e9mu st\u00fdka\u010du. <em>S_Int<\/em> na pr\u00edpojky 1 \/ 3 a 7 \/ 5 a pripojte ich cez pr\u00edpojky 2 (neutr\u00e1l) a 8 (f\u00e1za) k v\u00fdstupu meni\u010da, ktor\u00fd teraz nap\u00e1ja motorov\u00fd dom 230 V v re\u017eime meni\u010da.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Landstrom_abgeschaltet_%E2%80%93_Generator-Einsatz\"><\/span>Vypnut\u00e9 pobre\u017en\u00e9 nap\u00e1janie - pou\u017eitie gener\u00e1tora<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ke\u010f sa gener\u00e1tor spust\u00ed, st\u00fdka\u010d <em>S_Int<\/em> odpoj\u00ed pripojenie k meni\u010du a pripoj\u00ed jeho v\u00fdstup striedav\u00e9ho pr\u00fadu k 230 V sieti motorov\u00e9ho vozidla prostredn\u00edctvom kontaktov 1 a 2 (neutr\u00e1l) a 7 a 8 (f\u00e1za).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Landstrom_eingeschaltet\"><\/span>Zapnut\u00e9 pobre\u017en\u00e9 nap\u00e1janie<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ak je pripojen\u00e9 pobre\u017en\u00e9 nap\u00e1janie, st\u00fdka\u010d \u0165ah\u00e1 <em>S_Ext<\/em> odpoj\u00ed aktu\u00e1lne akt\u00edvne pripojenie 1 a 2 (neutr\u00e1l) alebo 7 a 8 (f\u00e1za) a nasmeruje neutr\u00e1l cez kontakty 3 a 4 alebo f\u00e1zu cez 5 a 6 do siete motorov\u00e9ho vozidla.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Automatisierter_Generator-Stop\"><\/span>Automatick\u00e9 zastavenie gener\u00e1tora<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ak pou\u017e\u00edvate syst\u00e9m SmartHome, m\u00f4\u017eete gener\u00e1tor automaticky vypn\u00fa\u0165 pri pr\u00edchode elektrickej energie z pevniny prepnut\u00edm zapa\u013eovania gener\u00e1tora na zem (zapnite rel\u00e9 paralelne s vyp\u00edna\u010dom zapa\u013eovania na 5 sek\u00fand).<br>Vypnutie rel\u00e9 po uplynut\u00ed vy\u0161\u0161ie uveden\u00e9ho \u010dasov\u00e9ho obdobia zabezpe\u010d\u00ed, \u017ee gener\u00e1tor bude po uplynut\u00ed tohto obdobia pripraven\u00fd na op\u00e4tovn\u00e9 spustenie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hinweis\"><\/span>N\u00e1poveda<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Ke\u010f\u017ee neexistuje \u017eiadne elektronick\u00e9 oneskorenie zapnutia nap\u00e1jania ani detekcia nulov\u00e9ho priechodu prich\u00e1dzaj\u00faceho striedav\u00e9ho nap\u00e4tia, okrem kr\u00e1tkeho \u010dasu sp\u00ednania st\u00fdka\u010da by sa sp\u00ednanie nemalo vykon\u00e1va\u0165 pri zna\u010dnom za\u0165a\u017een\u00ed. T\u00fdm sa chr\u00e1nia kontakty st\u00fdka\u010da na jednej strane a zariadenie na strane druhej, preto\u017ee najm\u00e4 po\u010d\u00edta\u010de nemaj\u00fa rady f\u00e1zov\u00fd posun, ku ktor\u00e9mu doch\u00e1dza po\u010das sp\u00ednania (rozdiel v \u010dase prechodu nuly striedav\u00e9ho nap\u00e4tia).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"%E2%80%93_Achtung_%E2%80%93\"><\/span>- Pozor -<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-cb34976054868c58986c3621c1b8dba5\" style=\"color:#ff0000\">V\u0161etky elektroin\u0161tala\u010dn\u00e9 pr\u00e1ce musia vykon\u00e1va\u0165 kvalifikovan\u00ed pracovn\u00edci v s\u00falade s platn\u00fdmi predpismi. Pri pr\u00e1ci na elektrick\u00fdch in\u0161tal\u00e1ci\u00e1ch musia by\u0165 v\u017edy bezpe\u010dne odpojen\u00e9 od nap\u00e4tia!<br>Na informovanie nez\u00fa\u010dastnen\u00fdch tret\u00edch str\u00e1n musia by\u0165 na vyp\u00ednacie zariadenia po\u010das trvania pr\u00e1c pripevnen\u00e9 pr\u00edslu\u0161n\u00e9 zna\u010dky.<br>Vy\u0161\u0161ie uveden\u00e9 inform\u00e1cie s\u00fa ur\u010den\u00e9 ako n\u00e1vrh a nerobia si n\u00e1rok na \u00faplnos\u0165, s\u00falad s pr\u00edslu\u0161n\u00fdmi predpismi, normami at\u010f. Ak\u00e1ko\u013evek zodpovednos\u0165 je vyl\u00fa\u010den\u00e1.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">\u010cas \u010d\u00edtania<\/span> <span class=\"rt-time\"> 5<\/span> <span class=\"rt-label rt-postfix\">z\u00e1pisnice<\/span><\/span>Wozu eine &#8211; automatische &#8211; Umschaltung der 230V-Quelle im Wohnmobil, mag man sich zun\u00e4chst fragen. Wer jedoch eine gewisse energietechnische Autarkie anstrebt, hat auch mehrere M\u00f6glichkeiten Wechselspannungs-Verbraucher zu speisen und zwischen diesen bedarfsweise zu wechseln. 230 V Quellen Die normale Wechselspannungs-Versorgung (AC &#8211; alternating current) erfolgt mit Landstrom, sofern man diesen nat\u00fcrlich verf\u00fcgbar hat. Unterwegs&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/sk\/blog\/2025\/06\/21\/umschaltung-230v-quelle-im-wohnmobil\/\" rel=\"bookmark\">\u010c\u00edta\u0165 viac \"<span class=\"screen-reader-text\">Sp\u00ednanie 230V zdroja v karavane<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[317,1757,1273,5081,346,1260,1582],"tags":[],"class_list":["post-10113","post","type-post","status-publish","format-standard","hentry","category-autarkie-im-wohnwagen-wohnmobil","category-elektrotechnik","category-hybrid-generator","category-relais-technik","category-smarthome","category-stromerzeugung","category-wechselrichter"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/posts\/10113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/comments?post=10113"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/posts\/10113\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/media?parent=10113"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/categories?post=10113"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/tags?post=10113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}