{"id":3823,"date":"2023-03-28T06:02:51","date_gmt":"2023-03-28T06:02:51","guid":{"rendered":"https:\/\/csiag.eu\/?p=3823"},"modified":"2023-03-28T06:05:13","modified_gmt":"2023-03-28T06:05:13","slug":"pretazenie-menica-victron-multiplus-ii","status":"publish","type":"post","link":"https:\/\/csiag.eu\/sk\/blog\/2023\/03\/28\/victron-multiplus-ii-inverter-overload\/","title":{"rendered":"Victron - Multiplus II - Pre\u0165a\u017eenie meni\u010da?"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">\u010cas \u010d\u00edtania<\/span> <span class=\"rt-time\"> &lt; 1<\/span> <span class=\"rt-label rt-postfix\">Min\u00fata<\/span><\/span>\n<p>Pr\u00edstroj Victron Multiplus II pracoval po cel\u00fd \u010das bezchybne. Zrazu sa zobraz\u00ed \"Overload\" a vypne sa, aby sa hne\u010f potom op\u00e4\u0165 zapol - a po chv\u00edli op\u00e4\u0165 hral t\u00fa ist\u00fa hru.<\/p>\n\n\n\n<p>Pre\u0165a\u017eenie? Pr\u00edli\u0161 ve\u013ek\u00e1 z\u00e1\u0165a\u017e? Poh\u013ead na <em>Dotykov\u00fd panel Victron Cerbo GX<\/em> ukazuje len pribli\u017ene 300 W z\u00e1\u0165a\u017e striedav\u00fdm pr\u00fadom. Pre\u010do teda doch\u00e1dza k pre\u0165a\u017eeniu? Asi 80 W prich\u00e1dza cez fotovoltaiku, tak\u017ee ani to nie je skuto\u010dn\u00e9 pre\u0165a\u017eenie.<\/p>\n\n\n\n<p>Ak budete okolnosti sledova\u0165 pozornej\u0161ie, zist\u00edte, \u017ee k poruche doch\u00e1dza v\u017edy, ke\u010f slnko svieti pln\u00fdm v\u00fdkonom. \u010co m\u00e1 teda slnko spolo\u010dn\u00e9 s pre\u0165a\u017een\u00edm?<\/p>\n\n\n\n<p>Teraz, <em>Victron Cerbo GX<\/em> a pripojen\u00e9 zariadenia sa navz\u00e1jom inteligentne ovl\u00e1daj\u00fa. Niekedy inteligentnej\u0161ie, ne\u017e pou\u017e\u00edvate\u013e...<\/p>\n\n\n\n<p>Preto\u017ee ke\u010f s\u00fa bat\u00e9rie pln\u00e9 a fotovoltika dod\u00e1va elektrinu, zariadenie Multiplus nevie, \u010do m\u00e1 robi\u0165 s prebyto\u010dnou elektrinou, a preto sa c\u00edti \"pre\u0165a\u017een\u00e9\" touto \u00falohou. Znamen\u00e1 to, \u017ee je potrebn\u00e9 vypn\u00fa\u0165 FV moduly? Nie, preto\u017ee riadiaci syst\u00e9m <em>Victron Cerbo GX<\/em> ove\u013ea lep\u0161ie. Mus\u00edte mu v\u0161ak v nastaveniach poveda\u0165, \u017ee m\u00e1 aj zdroj jednosmern\u00e9ho pr\u00fadu.<\/p>\n\n\n\n<p>Tak \u010falej <em>Dotykov\u00fd panel Victron Cerbo GX<\/em> vyvola\u0165 menu, zada\u0165 <em>Nastavenia<\/em> a v <em>Nastavenie syst\u00e9mu<\/em> aktivujte mo\u017enos\u0165 \"M\u00e1 DC\".<\/p>\n\n\n\n<p>V zobrazen\u00ed str\u00e1nok sa teraz v strede dolnej \u010dasti medzi symbolom bat\u00e9rie a regul\u00e1tora MPPT objavilo \u010fal\u0161ie informa\u010dn\u00e9 pole \"DC Power\".<\/p>\n\n\n\n<p>Teraz dokonca aj <em>Victron Multiplus II<\/em>\u017ee do procesu nab\u00edjania bat\u00e9rie s\u00fa okrem jej nab\u00edjac\u00edch slu\u017eieb zapojen\u00ed aj \u010fal\u0161\u00ed ochotn\u00ed pomocn\u00edci. A h\u013ea: u\u017e nevykazuje \u017eiadne \"pre\u0165a\u017eenie\" a teraz sa m\u00f4\u017ee op\u00e4\u0165 \u00faplne uvo\u013enene venova\u0165 vlastn\u00fdm \u00faloh\u00e1m.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">\u010cas \u010d\u00edtania<\/span> <span class=\"rt-time\"> &lt; 1<\/span> <span class=\"rt-label rt-postfix\">Min\u00fata<\/span><\/span>Pr\u00edstroj Victron Multiplus II pracoval po cel\u00fd \u010das bezchybne. Zrazu sa na displeji zobraz\u00ed \"Overload\" a vypne sa, aby sa hne\u010f potom op\u00e4\u0165 zapol - a po chv\u00edli za\u010dne op\u00e4\u0165 hra\u0165 t\u00fa ist\u00fa hru. Pre\u0165a\u017eenie? Pr\u00edli\u0161 ve\u013ek\u00e1 z\u00e1\u0165a\u017e? Poh\u013ead na dotykov\u00fd panel Victron Cerbo GX ukazuje len pribli\u017ene 300 W za\u0165a\u017eenie striedav\u00fdm pr\u00fadom. Pre\u010do...&nbsp;<a href=\"https:\/\/csiag.eu\/sk\/blog\/2023\/03\/28\/victron-multiplus-ii-inverter-overload\/\" rel=\"bookmark\">\u010c\u00edta\u0165 viac \"<span class=\"screen-reader-text\">Victron - Multiplus II - Pre\u0165a\u017eenie meni\u010da?<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[317,344],"tags":[521,1301,1297,1298,528,1289,1299,1300,519],"class_list":["post-3823","post","type-post","status-publish","format-standard","hentry","category-autarkie-im-wohnwagen-wohnmobil","category-victron-systemloesung","tag-cerbo-gx","tag-dc-power","tag-dc-quelle","tag-has-dc","tag-mppt-regler","tag-multiplus-ii-2","tag-overload","tag-ueberlast","tag-victron"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/posts\/3823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/comments?post=3823"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/posts\/3823\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/media?parent=3823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/categories?post=3823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/sk\/wp-json\/wp\/v2\/tags?post=3823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}