{"id":11143,"date":"2025-09-15T11:21:28","date_gmt":"2025-09-15T11:21:28","guid":{"rendered":"https:\/\/csiag.eu\/?p=11143"},"modified":"2025-09-15T11:31:02","modified_gmt":"2025-09-15T11:31:02","slug":"naetverksteknik-switchar-och-kablage","status":"publish","type":"post","link":"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/","title":{"rendered":"N\u00e4tverksteknik - switchar och kablage"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inneh\u00e5llsf\u00f6rteckning<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Netzwerk-Kabel\" >N\u00e4tverkskabel<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Abschirmung\" >avsk\u00e4rmning<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Klassifizierung_CAT\" >Klassificering (CAT)<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Glasfaser_vs_Kupfer\" >Fiberoptik kontra koppar<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Preisfrage\" >Fr\u00e5ga om pris<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Hub_vs_Switch\" >Hub vs. switch<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Hub\" >Stroke<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Switch\" >V\u00e4xla<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Ports\" >hamnar<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Switches_%E2%80%93_unmanaged\" >Switchar - (o)hanterade<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Hersteller_von_Switches\" >Tillverkare av str\u00f6mst\u00e4llare<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Cisco\" >Cisco<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/#Ubiquiti\" >Ubiquity<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minuter<\/span><\/span>\n<p class=\"wp-block-paragraph\">Switchar och kablage spelar en central roll i n\u00e4tverkstekniken. Skillnaderna och de urvalskriterier som b\u00f6r beaktas diskuteras nedan.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Netzwerk-Kabel\"><\/span>N\u00e4tverkskabel<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Abschirmung\"><\/span>avsk\u00e4rmning<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e4tverkskablar \u00e4r konstruerade som 4-pars tvinnade singelkablar med en gemensam kopparfl\u00e4tning f\u00f6r att avsk\u00e4rma externa st\u00f6rf\u00e4lt (S\/FTP <em><strong>S<\/strong>creened <strong>F<\/strong>oljad <strong>T<\/strong>f\u00f6rvr\u00e4ngd <strong>P<\/strong>luft<\/em>). Vridningen eliminerar internt uppkomna interferensf\u00e4lt.<br>Kablar med individuella tr\u00e5dpar som dessutom \u00e4r sk\u00e4rmade med fl\u00e4tning kallas S\/STP-kablar (<em><strong>S<\/strong>creened <strong>S<\/strong>h\u00f6lls <strong>T<\/strong>f\u00f6rvr\u00e4ngd<strong> P<\/strong>luft<\/em>). <br>F\u00f6r FTP-kablar (<em><em><strong>F<\/strong>oljad <strong>T<\/strong>f\u00f6rvr\u00e4ngd <strong>P<\/strong>luft<\/em><\/em>) anv\u00e4nds en aluminiumbelagd folie ist\u00e4llet f\u00f6r kopparfl\u00e4tning.<br>En s.k. dr\u00e4neringsledning fungerar som jordledning i alla varianter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">UTP-kablar (<em><strong>U<\/strong>avsk\u00e4rmad <strong>T<\/strong>f\u00f6rvr\u00e4ngd <strong>P<\/strong>luft<\/em>), som inte har n\u00e5gon sk\u00e4rmning och d\u00e4rf\u00f6r inte har en tv\u00e5tr\u00e5dig anslutning.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Klassifizierung_CAT\"><\/span>Klassificering (CAT)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kategorierna CAT1 till CAT6(A) omfattas inte, eftersom de inte l\u00e4ngre uppfyller dagens krav p\u00e5 bandbredd om 10 Gbit\/s Ethernet eller h\u00f6gre kr\u00e4vs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fr\u00e5n och med CAT7 \u00e4r tr\u00e5dparen individuellt sk\u00e4rmade. De uppfyller kraven f\u00f6r <a href=\"https:\/\/de.wikipedia.org\/wiki\/IEEE_802.3an\" target=\"_blank\" rel=\"noopener\">IEEE 802.3an<\/a>kan anv\u00e4ndas upp till 600 MHz, CAT7A upp till 1.000 MHz och datahastigheter p\u00e5 upp till 10 Gbit\/s i 10GBASE-T-applikationer.<br>Den maximala kabell\u00e4ngden \u00e4r 100 m vid den nominella \u00f6verf\u00f6ringshastigheten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den h\u00f6gsta datahastigheten uppn\u00e5s f\u00f6r n\u00e4rvarande med kablar i kategori CAT8.2, som har en bandbredd p\u00e5 2 Gbit\/s och en datahastighet p\u00e5 40 Gbit\/s f\u00f6r 25 GBASE-T- respektive 40 GBASE-T-applikationer.<br>Med 40GBASE-T \u00e4r kabell\u00e4ngden begr\u00e4nsad till 30 meter.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Glasfaser_vs_Kupfer\"><\/span>Fiberoptik kontra koppar<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prestandan hos kopparkablar, s\u00e4rskilt CAT8, \u00e4r nu j\u00e4mf\u00f6rbar med fiberoptik. Det finns dock en skillnad som bara kan realiseras med koppar, n\u00e4mligen PoE (<em><strong>P<\/strong>ower <strong>o<\/strong>ver <strong>E<\/strong>thernet<\/em>), str\u00f6mf\u00f6rs\u00f6rjningen till f\u00f6rbrukare som kameror via Ethernet-kabeln.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Om PoE inte kr\u00e4vs g\u00e5r trenden mot fiberoptik, \u00e4ven om hanteringen, till exempel montering av stickkontakterna, \u00e4r betydligt mer komplex och kr\u00e4ver specialverktyg.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Preisfrage\"><\/span>Fr\u00e5ga om pris<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prisskillnaden mellan CAT7(A) och CAT8(.1\/.2) \u00e4r marginell med 10%. Du kan r\u00e4kna med cirka 10 euro f\u00f6r 3m CAT7 och cirka 11 euro f\u00f6r CAT8.1.<br>Det \u00e4r dock viktigt att komma ih\u00e5g att infrastrukturen, t.ex. switchar, ocks\u00e5 m\u00e5ste uppfylla klassificeringskraven om de inte ska bli flaskhalsen i datafl\u00f6det.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hub_vs_Switch\"><\/span>Hub vs. switch<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hubbar och switchar anv\u00e4nds f\u00f6r att distribuera den inkommande datastr\u00f6mmen, t.ex. fr\u00e5n routern, via tillg\u00e4ngliga portanslutningar till slutenheter som datorer, skrivare, skannrar, kameror eller andra n\u00e4tverksenheter.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hub\"><\/span>Stroke<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hubben f\u00f6rdelar den inkommande datastr\u00f6mmen j\u00e4mnt \u00f6ver alla portar. Anslutna abonnenter tar emot datastr\u00f6mmen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Switch\"><\/span>V\u00e4xla<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En switch analyserar huvudet i den mottagna datastr\u00f6mmen. Den MAC-adress som identifieras definierar m\u00e5lenheten. Om MAC-adressen inte k\u00e4nns igen skickas datapaketet till alla portar. S\u00e5 snart den aktuella m\u00e5lenheten svarar s\u00e4nder den sin MAC-adress, som switchen sedan skriver in i sin CAM (<em><strong>C<\/strong>ontent <strong>A<\/strong>kl\u00e4dsam <strong>M<\/strong>emory<\/em>), \u00e4ven SAT-tabell (<em><strong>S<\/strong>ource-<strong>A<\/strong>kl\u00e4nning-<strong>T<\/strong>kapabel<\/em>) \u00e4r inmatad. Detta inneb\u00e4r att paket omedelbart kan vidarebefordras till r\u00e4tt destinationsadress med hj\u00e4lp av MAC-adressen.<br>Direkt tilldelning via MAC-adress f\u00f6rhindrar kollisioner mellan datapaket och m\u00f6jligg\u00f6r full-duplex-kommunikation, vilket optimerar datafl\u00f6det.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Switchar kan ocks\u00e5 skapa virtuella LAN (<em>VLAN<\/em>) och distribuerar datatrafiken till olika logiska n\u00e4tverk och behandlar dem d\u00e4rmed separat fr\u00e5n varandra.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ports\"><\/span>hamnar<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Antalet portar kan varieras, fr\u00e5n 4, 8, 16, 24 upp till 48 portar, allt finns tillg\u00e4ngligt p\u00e5 marknaden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00e4rf\u00f6r b\u00f6r du f\u00f6rst anteckna alla enheter som ska anslutas till en switch via LAN.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r att slutenheter ska kunna f\u00f6rs\u00f6rjas via PoE m\u00e5ste str\u00f6mf\u00f6rbrukningen tas med i ber\u00e4kningen. Det beror p\u00e5 att summan av alla PoE-portar best\u00e4mmer den totala effekt som kr\u00e4vs f\u00f6r switchens str\u00f6mf\u00f6rs\u00f6rjning - och d\u00e4rmed ocks\u00e5 priset.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En switch med 16 portar kan t.ex. ha 12 icke-PoE-portar och 4 PoE-portar. Det \u00e4r d\u00e4rf\u00f6r viktigt att kontrollera hur m\u00e5nga PoE-portar som faktiskt finns tillg\u00e4ngliga - och med vilken effekt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Med tanke p\u00e5 den st\u00e4ndigt v\u00e4xande n\u00e4tverksinfrastrukturen b\u00f6r man \u00f6verv\u00e4ga en viss reserv i antalet portar och PoE-portar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Switches_%E2%80%93_unmanaged\"><\/span>Switchar - (o)hanterade<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00e5nga tillverkare delar p\u00e5 marknaden. Enligt min mening \u00e4r det alltid l\u00e4mpligt att v\u00e4lja en tillverkare som \u00e4r aktiv inom aff\u00e4rssektorn och d\u00e4rf\u00f6r har god erfarenhet av detta marknadssegment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En \u00e5tskillnad m\u00e5ste g\u00f6ras mellan s\u00e5 kallade <em>hanterade<\/em> och <em>ohanterad<\/em> Omkopplare. Endast <em>hanterade<\/em> Switchar \u00e4r konfigurerbara. \u00c4ven om konfigurerbarhet s\u00e4llan \u00e4r viktigt f\u00f6r den enskilde anv\u00e4ndaren i b\u00f6rjan, \u00f6kar efterfr\u00e5gan med tiden och behovet av ett konfigurationsalternativ blir f\u00f6ruts\u00e4gbart, vilket oftast \u00e4r fallet i livet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Enkelheten i konfigurationen minskar med \u00f6kad professionalism och den d\u00e4rmed sammanh\u00e4ngande \u00f6kningen av den administrativa komplexiteten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En switch \"fungerar\" dock alltid i sin grundl\u00e4ggande fabrikskonfiguration. Detta inneb\u00e4r att det f\u00f6r n\u00e4rvarande inte kr\u00e4vs n\u00e5gon konfigurationsinsats, \u00e4ven om det \u00e4r valfritt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I detta avseende kan man nu f\u00f6rlita sig p\u00e5 <em>hanterade<\/em> v\u00e4xlar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Hersteller_von_Switches\"><\/span>Tillverkare av str\u00f6mst\u00e4llare<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Enligt min mening \u00e4r valets \u00e5ngest reducerad till tv\u00e5 tillverkare. Den som har en affinitet f\u00f6r Cisco kommer att v\u00e4lja Cisco utan tvekan. Den som \u00e4nnu inte \u00e4r partisk, inte har en o\u00e4ndlig budget till sitt f\u00f6rfogande och inte \u00e4r ett aff\u00e4rsproffs n\u00e4r det g\u00e4ller n\u00e4tverk kommer att l\u00e4ra sig att uppskatta Ubiquiti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gemensamt f\u00f6r de b\u00e5da tillverkarna \u00e4r att st\u00f6rre switchar (i vissa fall fr\u00e5n 8 eller 16 portar) i regel har uplink-portar (SFP\/SFP+ med 16 Gbit\/s eller Enhanced Quad-Small Form-factor Pluggable med 40 Gbit\/s (QSFP+)) via fiberoptiska anslutningar, vanligtvis 2 eller 4 stycken.<br>QSFP-DD (Double Density) st\u00f6der upp till 56 GBit\/s och 400 Gbit\/s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den maximala kabell\u00e4ngden f\u00f6r uplink-portar enligt ovanst\u00e5ende standarder \u00e4r 550 m (multimode) eller 10 km (singlemode LX), eller 40 km (singlemode EX) och 80 km (singlemode ZX), beroende p\u00e5 fibertyp. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CWDM- och DWDM-moduler m\u00f6jligg\u00f6r till och med avst\u00e5nd p\u00e5 upp till 80 eller 120 km, f\u00f6rutsatt att motsvarande s\u00e4ndningseffekt och mottagningsk\u00e4nslighet finns tillg\u00e4nglig.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cisco\"><\/span>Cisco<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Den mest k\u00e4nda tillverkaren \u00e4r f\u00f6rmodligen Cisco. Icke-professionella anv\u00e4ndare avskr\u00e4cks ofta av administrationen, som t\u00e4cker n\u00e4stan alla m\u00f6jligheter och d\u00e4rf\u00f6r \u00e4r mycket komplex. I den professionella milj\u00f6n \u00e4r Cisco oumb\u00e4rligt och en kvasistandard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SG och CBS (<em>Switch f\u00f6r Cisco-f\u00f6retag<\/em>) v\u00e4nder sig till privata anv\u00e4ndare, t.ex. sm\u00e5 och medelstora f\u00f6retag, Cisco Catalyst till industriella anv\u00e4ndare och Cisco Nexus till n\u00e4tverksstrukturer som kr\u00e4ver h\u00f6g skalbarhet och motsvarande prestanda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Ubiquiti\"><\/span>Ubiquity<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ubiquiti \u00e4r en tillverkare som ursprungligen var verksam inom den professionella sektorn, inte bara av switchar utan \u00e4ven WLAN- och radiorel\u00e4komponenter, som erbjuder ett konsumentsortiment med professionell teknik fr\u00e5n aff\u00e4rssektorn till \u00f6verkomliga priser.<br>Den k\u00e4nnetecknas ocks\u00e5 av 24\/7 online RealTime-support, som kan anropas fr\u00e5n styrenhetens GUI och \u00e4ven kan anslutas p\u00e5 distans. Sessionsloggar registreras och g\u00f6rs tillg\u00e4ngliga via e-post i slutet av sessionen. Detta g\u00f6r det m\u00f6jligt att i efterhand g\u00e5 tillbaka till de olika stegen i detalj.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">UniFi och Edge \u00e4r de divisioner som Ubiquiti erbjuder f\u00f6r konsument- och f\u00f6retagsmarknaden. B\u00e5da linjerna har f\u00f6rdelen med omfattande visualisering av hela n\u00e4tverket och central, dedikerad hantering via UniFi CloudKey Controller eller UniFi DreamMachine (UDM), s\u00e4rskilt i kombination med UniFi Camera System (UniFi Protect) eller UniFi DreamRouter (UDR).<br>Alla Pro- och Enterprise-varianter har st\u00f6d f\u00f6r ut\u00f6kade Layer 3-funktioner, t.ex. VLAN.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">minuter<\/span><\/span>In der Netzwerktechnik nehmen Switches und die Verkabelung zentrale Funktionen ein. Was zu beachtende Unterschiede und Auswahlkriterien betrifft, soll nachfolgend er\u00f6rtert werden. Netzwerk-Kabel Abschirmung Netzwerkkabel sind als 4-paarig verdrillte Einzelkabel mit gemeinsamem Kupfer-Geflecht zur Abschirmung externer St\u00f6rfelder ausgef\u00fchrt (S\/FTP &#8211; Screened Foiled Twisted Pair). Die Verdrillung eliminiert intern auftretende St\u00f6rfelder.Kabel mit einzeln zus\u00e4tzlich mit Geflecht&hellip;&nbsp;<a href=\"https:\/\/csiag.eu\/sv\/blog\/2025\/09\/15\/netzwerktechnik-switches-und-verkabelung\/\" rel=\"bookmark\">L\u00e4s mer \"<span class=\"screen-reader-text\">N\u00e4tverksteknik - switchar och kablage<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2553],"tags":[],"class_list":["post-11143","post","type-post","status-publish","format-standard","hentry","category-netzwerk-technik"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts\/11143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/comments?post=11143"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts\/11143\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/media?parent=11143"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/categories?post=11143"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/tags?post=11143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}