{"id":2392,"date":"2022-10-22T16:08:11","date_gmt":"2022-10-22T16:08:11","guid":{"rendered":"https:\/\/csiag.eu\/?p=2392"},"modified":"2022-12-28T13:01:19","modified_gmt":"2022-12-28T13:01:19","slug":"apc-ups-med-externa-batterier","status":"publish","type":"post","link":"https:\/\/csiag.eu\/sv\/blog\/2022\/10\/22\/apc-usv-mit-externen-batterien\/","title":{"rendered":"APC UPS med externa batterier"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inneh\u00e5llsf\u00f6rteckning<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/sv\/blog\/2022\/10\/22\/apc-usv-mit-externen-batterien\/#Lade-Technik\" >Laddningsteknik<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/sv\/blog\/2022\/10\/22\/apc-usv-mit-externen-batterien\/#Umschaltung_%E2%80%93_Landstrom_Notstrom\" >Omkoppling \u2013 landstr\u00f6m &lt;&gt; n\u00f6dstr\u00f6m<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/sv\/blog\/2022\/10\/22\/apc-usv-mit-externen-batterien\/#Verbraucher_und_Standzeit\" >Konsumenter och stillest\u00e5nd<\/a><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minuter<\/span><\/span>\n<p>Pro-serien fr\u00e5n APC \u00e4r l\u00e4mplig som n\u00f6dstr\u00f6mf\u00f6rs\u00f6rjning. Den fungerar med tv\u00e5 12 V 9 Ah-batterier kopplade i serie, det vill s\u00e4ga 24 V, levererar 1 500 VA, motsvarande 865 W. Den levererar dock bara cirka 400 watt i 12 minuter (vid exakt 432 W), eller cirka 5 minuter vid full effekt. ladda. Alternativt har den en anslutningsplint f\u00f6r externa batteripaket.<\/p>\n\n\n\n<p>Tv\u00e5 12 V 80 Ah batterier i serie \u00e4r en billig batterif\u00f6rl\u00e4ngning. Detta ger dig 89 Ah, vilket inneb\u00e4r cirka 50 minuters full belastning eller 100 minuter med 50 % belastning.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Lade-Technik\"><\/span>Laddningsteknik<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Eftersom APC:s laddningskrets inte anv\u00e4nder den ultimata skonsamma laddningsalgoritmen, rekommenderas att anv\u00e4nda en laddningsbooster med en integrerad 12 V \/ 24 V - DCDC-omvandlare <a href=\"https:\/\/www.amazon.de\/Victron-Orion-Tr-24-10A-Wandler-Ladebooster\/dp\/B086R9H4QV\/ref=sr_1_1?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=H9I2M94CUKRK&amp;keywords=victron+orion+tr+smart+12%2F24+10a&amp;qid=1666453341&amp;qu=eyJxc2MiOiIxLjM1IiwicXNhIjoiMC4wMCIsInFzcCI6IjAuMDAifQ%3D%3D&amp;sprefix=victron+orio+tr+smart+12%2F24+10a%2Caps%2C269&amp;sr=8-1\" target=\"_blank\" rel=\"noreferrer noopener\">Victron Orion TR Smart 12\/24 10A<\/a> med 240 W effekt f\u00f6r att s\u00e4kerst\u00e4lla l\u00e5ng livsl\u00e4ngd f\u00f6r batterierna.<\/p>\n\n\n\n<p>DCDC-omvandlaren aktiveras via en ignition plus-anslutning, som ansluts till H-ing\u00e5ngen efter att den befintliga kabelbryggan tagits bort. Omvandlaren har en integrerad f\u00f6rdr\u00f6jningskrets (standard 120s), som aktiverar laddning av batteriet anslutet p\u00e5 utg\u00e5ngssidan f\u00f6rst efter att den inst\u00e4llda tidsperioden har f\u00f6rflutit.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Umschaltung_%E2%80%93_Landstrom_Notstrom\"><\/span>Omkoppling \u2013 landstr\u00f6m &lt;&gt; n\u00f6dstr\u00f6m<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>A anv\u00e4nds f\u00f6r att automatiskt v\u00e4xla mellan landstr\u00f6m och UPS n\u00f6dstr\u00f6mf\u00f6rs\u00f6rjning <a href=\"https:\/\/www.h-tronic.de\/shop\/mpc1000-umschaltstation\/\" target=\"_blank\" rel=\"noreferrer noopener\">HTRONIC v\u00e4xelstation<\/a>, identisk i konstruktion med ELV MPC1000, anv\u00e4nd. H\u00e4r ansluts belastningen till den mellersta anslutningsterminalen (Load), utg\u00e5ngen fr\u00e5n UPS-n\u00f6dstr\u00f6mf\u00f6rs\u00f6rjningen till den v\u00e4nstra terminalen (Slave) och landstr\u00f6msledningen till h\u00f6ger (Master).<\/p>\n\n\n\n<p>F\u00f6r att bibeh\u00e5lla de olika fasl\u00e4gena f\u00f6r b\u00e5da kraftk\u00e4llorna installeras en justerbar f\u00f6rdr\u00f6jningskrets, som v\u00e4xlar \u00f6ver efter x millisekunder i enlighet med f\u00f6rlusten av en av de tv\u00e5 k\u00e4llorna.<\/p>\n\n\n\n<p>R\u00e4tt (master\/landstr\u00f6m) anslutning har alltid prioritet.<\/p>\n\n\n\n<p>P\u00e5lagd sp\u00e4nning signaleras av en lysdiod. Om det finns landstr\u00f6m och UPS-enheten \u00e4r p\u00e5slagen lyser b\u00e5da lysdioderna (master och slav), inklusive den f\u00f6r lastutg\u00e5ngen.<\/p>\n\n\n\n<p>Om landstr\u00f6m \u00e4r tillg\u00e4nglig laddar Victron Blue Smart IP22 som laddare 24\/161 de tv\u00e5 12V-batterier som \u00e4r seriekopplade.<\/p>\n\n\n\n<p>Ett h\u00f6gstr\u00f6msrel\u00e4 <a href=\"https:\/\/www.ebay.de\/itm\/185450915119?hash=item2b2dbc652f:g:qb0AAOSw9NNi0S1T&amp;amdata=enc%3AAQAHAAAA8ItJ25MlQoWDMRh%2FI3V3TA7jzCF1Cjxmciefsg0GGlYxtUPd0NLXfdoRkT3QiY%2F6UDX8xQawU6Uj7zbnPH5ILqZ7tErw3rEkgNhhZ7BDUv74Uo2%2BZG%2F8oB3WofgBU6HIKvLlR9M344OdnwWyGsNU1UqCvy2k6TyCZEDkbGlpDXLVLV2Jxd4M6z%2BaCHaWh8TUb8ms2cB5cIryivnSzVi1tWqgpBKrcuwpNZGqpZ%2BGl7eTNO4vzbcUdO2EtD3br%2B1OMcU8igbcGsJjctf6Mbis0eYblabSMAru1wHOTZePB8NLClSKBCoy5jSNaMwViNFKhg%3D%3D%7Ctkp%3ABFBM9ML0hYBh\" target=\"_blank\" rel=\"noreferrer noopener\">RL200\/12V isoleringsrel\u00e4<\/a> N\u00e4r den \u00e4r ansluten, se till att pluskabeln f\u00f6r de tv\u00e5 seriekopplade batterierna \u00e4r ansluten till pluspolen p\u00e5 APC-anslutningsterminalen. Med landstr\u00f6mf\u00f6rs\u00f6rjning f\u00f6rhindrar detta APC-laddningskretsen fr\u00e5n att ladda de tv\u00e5 externa batterierna - med den mindre v\u00e4nliga laddningsalgoritmen - och detta \u00e4r reserverat f\u00f6r DCDC-omvandlaren under k\u00f6rning.<\/p>\n\n\n\n<p>P\u00e5 detta s\u00e4tt buffras batteristr\u00f6mmen som anv\u00e4nds av APC:n omedelbart igen och leveranstiden f\u00f6r UPS:n f\u00f6rl\u00e4ngs avsev\u00e4rt.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Verbraucher_und_Standzeit\"><\/span>Konsumenter och stillest\u00e5nd<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Mac Mini M1 installerad h\u00e4r och de fyra 15,6\u2033-sk\u00e4rmarna, inklusive de tv\u00e5 HDMI-f\u00f6rl\u00e4ngarna, kr\u00e4ver maximalt cirka 35 W, vilket b\u00f6r till\u00e5ta upp till 18 timmars ren UPS-drift utan n\u00e5gon omladdning. \u00c4ven driften av LASER-skrivaren \u00e4r m\u00f6jlig utan problem, vilket naturligtvis f\u00f6rkortar den tidigare n\u00e4mnda tidsperioden.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minuter<\/span><\/span>Pro-serien fr\u00e5n APC \u00e4r l\u00e4mplig som n\u00f6dstr\u00f6msf\u00f6rs\u00f6rjning. Den fungerar med tv\u00e5 seriekopplade batterier p\u00e5 12 V 9 Ah, dvs. 24 V, och levererar 1.500 VA, motsvarande 865 W. Den levererar dock bara ca 400 watt i 12 minuter (vid exakt 432 W), eller ca 5 minuter vid full belastning. Den har dock ocks\u00e5 en extra...&nbsp;<a href=\"https:\/\/csiag.eu\/sv\/blog\/2022\/10\/22\/apc-usv-mit-externen-batterien\/\" rel=\"bookmark\">L\u00e4s mer \"<span class=\"screen-reader-text\">APC UPS med externa batterier<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[327,1],"tags":[429,432,431,434,433,430],"class_list":["post-2392","post","type-post","status-publish","format-standard","hentry","category-apc-usv-mit-externen-batterien","category-uncategorized","tag-apc","tag-batterie","tag-dcd-wandler","tag-ladegeraet","tag-umschaltstation","tag-usv"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts\/2392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/comments?post=2392"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts\/2392\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/media?parent=2392"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/categories?post=2392"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/tags?post=2392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}