{"id":5358,"date":"2023-10-14T17:50:51","date_gmt":"2023-10-14T17:50:51","guid":{"rendered":"https:\/\/csiag.eu\/?p=5358"},"modified":"2023-10-14T17:57:38","modified_gmt":"2023-10-14T17:57:38","slug":"naetverksteknik-patchpanel","status":"publish","type":"post","link":"https:\/\/csiag.eu\/sv\/blog\/2023\/10\/14\/netzwerktechnik-patchfeld\/","title":{"rendered":"N\u00e4tverksteknik \u2013 patchpanel"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minuter<\/span><\/span><p>Inom n\u00e4tverkstekniken finns vanligtvis ett s\u00e5 kallat patchf\u00e4lt i st\u00f6rre installationer. Olika n\u00e4tverkskablar ansluts till fronten och leder till routrar, switchar, brandv\u00e4ggar och andra n\u00e4tverkskomponenter.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5359 aligncenter\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Patchfeld-300x200.jpg\" alt=\"\" width=\"516\" height=\"345\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Patchfeld-300x200.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Patchfeld-930x620.jpg 930w\" sizes=\"(max-width: 516px) 100vw, 516px\" \/><\/p>\n<p>Orange n\u00e4tverksinstallationskablar leder in p\u00e5 baksidan och kommer ut fr\u00e5n golvet, v\u00e4ggen eller taket bakom n\u00e4tverkssk\u00e5pet d\u00e4r s\u00e5dana patchpaneler \u00e4r installerade.<\/p>\n<p><a href=\"https:\/\/www.amazon.de\/Netzwerkkabel-Verlegekabel-Halogenfrei-RoHS-Compliant-verbundene-Orange\/dp\/B0849T62N8\/ref=sr_1_1_sspa?crid=N375J4WNZKT&amp;keywords=netzwerk%2Bverlegekabel%2B20m&amp;qid=1697305618&amp;sprefix=netzwewrkverlege%2Caps%2C151&amp;sr=8-1-spons&amp;sp_csd=d2lkZ2V0TmFtZT1zcF9hdGY&amp;th=1\" target=\"_blank\" rel=\"noopener\">N\u00e4tverksinstallationskabel<\/a> kan till exempel j\u00e4mf\u00f6ras med de styva mantlade kablarna inom elektroteknik, som kommer fr\u00e5n de enskilda rummen i ett hus och konvergerar i m\u00e4tarsk\u00e5pet. N\u00e4tverksinstallationskabeln \u00e4r ocks\u00e5 styv och d\u00e4rf\u00f6r k\u00e4nslig f\u00f6r brott. Den har b\u00f6jradier p\u00e5 35 .. 70 mm, vilket kr\u00e4ver f\u00f6rl\u00e4ggning i kabelkanaler med ett minsta djup p\u00e5 cirka 70 mm. Detta \u00e4r inte ett problem i en industriell\/kommersiell milj\u00f6, s\u00e4rskilt eftersom installationen vanligtvis utf\u00f6rs i falska golv eller tak, s\u00e5v\u00e4l som br\u00f6stningskanaler.<\/p>\n<p>I privata och mindre kommersiella milj\u00f6er \u2013 upp till ett dussintal n\u00e4tverksenheter som ska anslutas, s\u00e5som datorer, skrivare, skannrar, \u00e5tkomstpunkter \u2013 etc., kan du enkelt klara dig utan att anv\u00e4nda en patchpanel. Dessutom vill folk inte se kablar, s\u00e4rskilt inte i vardagsrum, s\u00e5 de g\u00f6mmer dem i lika oansenliga, tunna kabelkanaler, bakom golvlister, i d\u00f6rromr\u00e5det under l\u00e4mpliga passageprofiler. Eftersom stela n\u00e4tverksinstallationskablar \u00e4r opraktiska h\u00e4r anv\u00e4nds de <a href=\"https:\/\/www.amazon.de\/BIGtec-Patchkabel-Netzwerkkabel-Kupferkabel-geschirmt\/dp\/B00IHIZK9S\/ref=sr_1_4?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=2CBNC5AX6XVDG&amp;keywords=bigtec%2Bcat%2B7%2Bnetzwerkkabel%2B10m&amp;qid=1697305680&amp;sprefix=bigtec%2Bcat%2B7%2Bnetzwerkkabel%2B10m%2Caps%2C186&amp;sr=8-4&amp;th=1\" target=\"_blank\" rel=\"noopener\">flexibel n\u00e4tverkskabel<\/a>, s\u00e5 kallade patch-kablar, med gjutna pluggar. Denna \u00e4r mindre k\u00e4nslig f\u00f6r brottrisk och ska inte b\u00f6jas utan kan l\u00e4ggas i smala radier, det vill s\u00e4ga i kabelkanaler som bara \u00e4r 15 mm djupa.<\/p>\n<p>N\u00e4r det g\u00e4ller \u00f6verf\u00f6ringsteknik, f\u00f6rutsatt kvalitativ j\u00e4mf\u00f6rbarhet, finns det ingen skillnad i prestanda f\u00f6r de tv\u00e5 typerna av kabel.<\/p>\n<h1>Installera installationskabeln<\/h1>\n<p>\u00c4ven om f\u00f6rmonterade n\u00e4tverkskablar inte kr\u00e4ver n\u00e5gon installation - koppla in och du \u00e4r klar - installationskablar har inga gjutna pluggar. Den kommer p\u00e5 stora kabelrullar och l\u00e4ggs som den mantlade kabeln som n\u00e4mns ovan. I skalet kan du se \u00e4ndarna dingla runt i v\u00e4ntan p\u00e5 att bli kopplade till kopplingsdosor eller patchpanelen.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-5360 aligncenter\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Kabel-300x204.jpg\" alt=\"\" width=\"513\" height=\"318\" \/><\/p>\n<p>N\u00e4tverksinstallationskabel installeras med en speciell <a href=\"https:\/\/www.amazon.de\/deleyCON-Auflegewerkzeug-Anlegewerkzeug-Netzwerkdosen-Netzwerkverdrahtung\/dp\/B09MQPJLVJ\/ref=sr_1_2_sspa?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&amp;crid=1NRW0J72XFFMH&amp;keywords=auflegewerkzeug&amp;qid=1697305562&amp;sprefix=auflegewerkzeug%2Caps%2C165&amp;sr=8-2-spons&amp;sp_csd=d2lkZ2V0TmFtZT1zcF9hdGY&amp;psc=1\" target=\"_blank\" rel=\"noopener\">uppl\u00e4ggningsverktyg<\/a> placeras och pressas in i sk\u00e4rkontakterna p\u00e5 st\u00f6dblocket p\u00e5 en kopplingsdosa eller inuti en patchpanel. Utskjutande ledningar sk\u00e4rs automatiskt av i ett j\u00e4mnt steg,<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-5362 aligncenter\" src=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss-300x161.jpg\" alt=\"\" width=\"515\" height=\"276\" srcset=\"https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss-300x161.jpg 300w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss-768x412.jpg 768w, https:\/\/csiag.eu\/wp-content\/uploads\/2023\/10\/Cat.7-Anschluss.jpg 800w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/><\/p>\n<p>Beroende p\u00e5 vilken standard som anv\u00e4nds (EIA\/TIA 568A \/ 568B, IEC, REA eller DIN 47.100) \u00e4r det viktigt att s\u00e4kerst\u00e4lla att de f\u00e4rgkodade \u00e5tta individuella ledningarna i kabeln \u00e4r korrekt tilldelade de \u00e5tta f\u00e4rgkodade anslutningsplintarna. Denna standard m\u00e5ste bibeh\u00e5llas genom hela installationen, inklusive eftermontering. I Europa \u00e4r kabeldragning att f\u00f6redra enligt EIA\/TIA 568A.<\/p>\n<p>Vilken standard som i slut\u00e4ndan anv\u00e4nds \u00e4r elektriskt irrelevant. Det enda som spelar roll \u00e4r att samma tr\u00e5dkodning alltid r\u00e5der p\u00e5 alla anslutningar.<\/p>\n<p>Om b\u00e5da \u00e4ndarna \u00e4r korrekt anslutna p\u00e5 detta s\u00e4tt kontrolleras tr\u00e5dtilldelning, kortslutning eller l\u00f6s kontakt med en n\u00e4tverkstestare. En testrapport ligger slutligen kvar hos kunden.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">L\u00e4stid<\/span> <span class=\"rt-time\"> 2<\/span> <span class=\"rt-label rt-postfix\">minuter<\/span><\/span>Inom n\u00e4tverksteknik \u00e4r en s\u00e5 kallad patchpanel vanligtvis f\u00f6rekommande i st\u00f6rre installationer. P\u00e5 framsidan kopplas olika n\u00e4tverkskablar in som leder till routrar, switchar, brandv\u00e4ggar och andra n\u00e4tverkskomponenter. P\u00e5 baksidan g\u00e5r orangef\u00e4rgade n\u00e4tverksinstallationskablar som kommer ut fr\u00e5n golvet, v\u00e4ggen eller taket bakom det n\u00e4tverkssk\u00e5p d\u00e4r s\u00e5dana patchpaneler \u00e4r installerade. N\u00e4tverksinstallationskablar kan t.ex. anv\u00e4ndas tillsammans med styva mantlade kablar...&nbsp;<a href=\"https:\/\/csiag.eu\/sv\/blog\/2023\/10\/14\/netzwerktechnik-patchfeld\/\" rel=\"bookmark\">L\u00e4s mer \"<span class=\"screen-reader-text\">N\u00e4tverksteknik \u2013 patchpanel<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"off","neve_meta_content_width":70,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[2553],"tags":[2560,2561,1045,2558,2566,2562,2563,2564,2559,2556,2554,2555,2557,2565],"class_list":["post-5358","post","type-post","status-publish","format-standard","hentry","category-netzwerk-technik","tag-anschlussdose","tag-auflegeblock","tag-auflegewerkzeug","tag-biegeradius","tag-din-47100","tag-eia-tia-568a","tag-eia-tia-568b","tag-iec","tag-kabelkanal","tag-netzwerk-verlegekabel","tag-netzwerktechnik","tag-patchfeld","tag-patchkabel","tag-rea"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts\/5358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/comments?post=5358"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/posts\/5358\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/media?parent=5358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/categories?post=5358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/sv\/wp-json\/wp\/v2\/tags?post=5358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}