{"id":3126,"date":"2023-01-12T10:01:59","date_gmt":"2023-01-12T10:01:59","guid":{"rendered":"https:\/\/csiag.eu\/?p=3126"},"modified":"2023-09-05T11:16:02","modified_gmt":"2023-09-05T11:16:02","slug":"fotovoltaik","status":"publish","type":"post","link":"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/","title":{"rendered":"Fotovoltaik"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0130\u00e7indekiler tablosu<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Rechtslage_zum_01012021\" >Yasal durum 01.01.2021 itibariyle<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Vergutung_fur_eingespeisten_Strom\" >\u015eebekeye verilen elektrik i\u00e7in \u00fccretlendirme<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Auswahl_der_PV-Module\" >PV mod\u00fcllerinin se\u00e7imi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Kleines_Wechselrichter_1%C3%971\" >K\u00fc\u00e7\u00fck invert\u00f6r 1\u00d71<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Technische_Wechselrichter-Details\" >Teknik invert\u00f6r detaylar\u0131<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Eingangsphasen\" >Giri\u015f a\u015famalar\u0131<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#AC_Nennleistung\" >AC nominal g\u00fc\u00e7<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Anzahl_MPP_Tracker\" >MPP izleyici say\u0131s\u0131<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#MPP_Bereich\" >MPP aral\u0131\u011f\u0131<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Eingangsstrom\" >Giri\u015f ak\u0131m\u0131<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Leerlaufspannung\" >A\u00e7\u0131k devre gerilimi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/#Wirkungsgrad\" >Verimlilik<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Okuma s\u00fcresi<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">dakika<\/span><\/span>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Rechtslage_zum_01012021\"><\/span>Yasal durum 01.01.2021 itibariyle<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Yeni Yenilenebilir Enerji Kaynaklar\u0131 Yasas\u0131 (EEG), fotovoltaik sistemler de dahil olmak \u00fczere 1 Ocak 2021 tarihinde y\u00fcr\u00fcrl\u00fc\u011fe girmi\u015ftir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, eski ve yeni fotovoltaik sistemlerden 30 kWp'ye kadar olan \u00f6z t\u00fcketimin EEG ek \u00fccretinden muaf oldu\u011fu anlam\u0131na gelmektedir. Ak\u0131ll\u0131 saya\u00e7lar\u0131n 7 kWp'ye kadar \u00f6z t\u00fcketim i\u00e7in veri toplama amac\u0131yla kurulmas\u0131na gerek yoktur.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Vergutung_fur_eingespeisten_Strom\"><\/span>\u015eebekeye verilen elektrik i\u00e7in \u00fccretlendirme<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tarife garantisi, artan \u00fcretim ve ilk devreye alma tarihi ile birlikte azal\u0131r. Bu, sistem ne kadar \u00e7ok \u00fcretim yaparsa ve ne kadar ge\u00e7 kurulursa, tarife garantisinin o kadar d\u00fc\u015f\u00fck olaca\u011f\u0131 anlam\u0131na gelir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1 Eyl\u00fcl 2021 tarihinde devreye al\u0131nan sistemlere 10 kWp'ye kadar 0,0725 Avro \u00f6denecektir. Sat\u0131n al\u0131nan elektrik i\u00e7in kWh ba\u015f\u0131na 0,30 ... 0,35 Euro'luk \u00fccretlendirme, sat\u0131n al\u0131nan elektrik i\u00e7in \u00f6denecek fiyat\u0131n yakla\u015f\u0131k 20%'sini temsil etmektedir. Herkes \u015febekeye elektrik beslemeye de\u011fip de\u011fmeyece\u011fine kendisi karar verebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00fcm\u00fcn\u00fc kullanmak daha mant\u0131kl\u0131 olabilir <a href=\"https:\/\/csiag.eu\/tr\/oekonomisches-energiemanagement\/#Zuviel\" rel=\"sponsored nofollow\">Kendi t\u00fcketimimiz<\/a> ol.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Auswahl_der_PV-Module\"><\/span>PV mod\u00fcllerinin se\u00e7imi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PV mod\u00fclleri eskiden \u00e7ok daha pahal\u0131 ve \u00e7ok daha az verimliyken, bug\u00fcn mevcut olan tasar\u0131m, \u00e7\u0131k\u0131\u015f, verimlilik vb. \u00e7e\u015fitlili\u011fi \u00e7ok b\u00fcy\u00fckt\u00fcr.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mutlu ortam\u0131 bulmak kolay de\u011fildir, ancak ger\u00e7ekle\u015ftirilebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tan\u0131nm\u0131\u015f bir \u00fcretici, az say\u0131da mod\u00fcl gerektiren, m\u00fcmk\u00fcn olan en y\u00fcksek verimlili\u011fi sunan ve istenen \u00e7\u0131kt\u0131ya m\u00fcmk\u00fcn oldu\u011funca yakla\u015fan bir tasar\u0131m se\u00e7in.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tasar\u0131m genellikle dikd\u00f6rtgen \u015feklindedir, ancak mod\u00fcllerin geni\u015fli\u011fi ve uzunlu\u011fu farkl\u0131l\u0131k g\u00f6sterir. Bu nedenle mod\u00fcl boyutunu se\u00e7erken mevcut alan s\u0131n\u0131rlay\u0131c\u0131 fakt\u00f6rd\u00fcr. Birka\u00e7 s\u0131ra in\u015fa edilirse, ilk s\u0131ran\u0131n arkas\u0131ndaki mod\u00fcllerin g\u00f6lgelenmesi dikkate al\u0131nmal\u0131d\u0131r. G\u00fcne\u015f al\u00e7ald\u0131\u011f\u0131nda bir sonraki s\u0131raya g\u00f6lge d\u00fc\u015fmemesi i\u00e7in mod\u00fcl s\u0131ralar\u0131 aras\u0131nda uygun bir mesafe planlaman\u0131z gerekir. Bu, kullan\u0131labilir alan\u0131 en aza indirir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gerekli mesafeler yaz\u0131l\u0131m kullan\u0131larak veya daha basit bir \u015fekilde \u00e7izilerek belirlenebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bunun i\u00e7in gerekli veriler \u015funlard\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Kurulum alan\u0131n\u0131n co\u011frafi uzunlu\u011fu \/ geni\u015fli\u011fi<\/li>\n\n\n\n<li>K\u0131\u015f g\u00fcnd\u00f6n\u00fcm\u00fcnde g\u00fcne\u015fin azimutu 12:00 h<\/li>\n\n\n\n<li>Mod\u00fcl\u00fcn \u00fcst kenar\u0131n\u0131n y\u00fckseklik y\u00fcksekli\u011fi<\/li>\n\n\n\n<li>Y\u00fckseklik a\u00e7\u0131s\u0131 (genellikle 30\u00b0)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bunun iyi bir dok\u00fcmantasyonu \u015fu eserde bulunabilir <a href=\"https:\/\/www.volker-quaschning.de\/downloads\/staffelstein1998_1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Dr.-Ing. Volker Quaschning ve Prof. Dr.-Ing. habil. Rolf Hanitsch<\/a>. Genellikle oldu\u011fu gibi, optimum bir sonu\u00e7 her zaman \u00e7aba gerektirir, sadece bunun temelini olu\u015fturan teorik hususlara a\u015fina olmak a\u00e7\u0131s\u0131ndan bile olsa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Verilen parametreler belirlendikten sonra, bir sonraki ad\u0131m do\u011fru mod\u00fclleri bulmakt\u0131r. Maksimum 7 kW i\u00e7in, her biri 350 W'l\u0131k 20 mod\u00fcl uygundur ve bunlar her biri 10 mod\u00fclden olu\u015fan 2 dizi halinde ba\u011flanabilir.<br>Bir dizi, mod\u00fcllerin seri ba\u011flant\u0131s\u0131n\u0131 ifade eder. \u00d6rnek bir mod\u00fcl MPP (Maksimum G\u00fc\u00e7 Noktas\u0131) voltaj\u0131 35 V, 350 V DC'lik bir invert\u00f6r giri\u015f voltaj\u0131 ile sonu\u00e7lan\u0131r. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Olas\u0131 dizilerin say\u0131s\u0131 inverter se\u00e7imine ba\u011fl\u0131d\u0131r. K\u00fc\u00e7\u00fck invert\u00f6rlerde yaln\u0131zca bir MPP izleyici bulunur ve bu nedenle yaln\u0131zca tek bir dizinin ba\u011flanmas\u0131na izin verir.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Kleines_Wechselrichter_1%C3%971\"><\/span>K\u00fc\u00e7\u00fck invert\u00f6r 1\u00d71<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Temel olarak \u00fc\u00e7 tip invert\u00f6r vard\u0131r; \u015febekeye ba\u011fl\u0131 veya \u015febekeden ba\u011f\u0131ms\u0131z olanlar veya her iki \u00e7al\u0131\u015fma modunun bir kombinasyonu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>A\u011f g\u00fcd\u00fcml\u00fc<\/em> \u0130nvert\u00f6rler kendilerini 50 Hz \u015febeke frekans\u0131 ile senkronize eder. Bir elektrik kesintisi durumunda bu ba\u015far\u0131s\u0131z olursa, elektrik kesintisi s\u00fcresince \u00e7al\u0131\u015fmay\u0131 durdururlar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>A\u011fdan ba\u011f\u0131ms\u0131z<\/em> \u0130nvert\u00f6rler, ba\u011f\u0131ms\u0131z sistemlerde, yani kamu \u015febekesine ba\u011fl\u0131 olmayan ba\u011f\u0131ms\u0131z PV sistemlerinde kullan\u0131l\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Her iki \u00e7al\u0131\u015fma modunu birle\u015ftiren invert\u00f6rler \u015fu \u015fekilde adland\u0131r\u0131l\u0131r <em>Hibrit<\/em>-Bir yandan kamu \u015febekesine ba\u011flan\u0131rken, ayn\u0131 zamanda MPPT kontrol\u00f6rleri arac\u0131l\u0131\u011f\u0131yla, g\u00fcne\u015f parlad\u0131\u011f\u0131nda da ba\u011fl\u0131 olan PV mod\u00fclleri taraf\u0131ndan \u015farj edilen ak\u00fclere ba\u011flan\u0131rlar. \u015eebeke ar\u0131zas\u0131 durumunda, hibrit invert\u00f6r basit\u00e7e ak\u00fc i\u015fletimine ge\u00e7er ve b\u00f6ylece g\u00fc\u00e7 kayna\u011f\u0131n\u0131 y\u00fck s\u0131n\u0131rlar\u0131 dahilinde tutar. Genel \u015febeke tekrar kullan\u0131labilir oldu\u011funda, ak\u00fc \u015farj\u0131na ge\u00e7er.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Technische_Wechselrichter-Details\"><\/span>Teknik invert\u00f6r detaylar\u0131<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130nvert\u00f6r olarak \u00fc\u00e7 fazl\u0131 bir cihaz se\u00e7ilebilir, \u00f6rne\u011fin 2.000 Euro'nun hemen alt\u0131nda bir Kostal Piko IQ 8.5. Tek fazl\u0131 cihazlar sadece 5 kW'a kadar mevcuttur, \u00f6rne\u011fin yakla\u015f\u0131k 1.200 Euro'luk Kostal Piko MP plus 5.0-2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Her iki cihazda da iki MPP izleyici vard\u0131r (iki dizinin ba\u011flant\u0131s\u0131).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bir invert\u00f6r se\u00e7erken hangi veriler \u00f6nemlidir?<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Eingangsphasen\"><\/span>Giri\u015f a\u015famalar\u0131<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yakla\u015f\u0131k 5 kW'a kadar olan daha k\u00fc\u00e7\u00fck inverterler genellikle bir faz, daha b\u00fcy\u00fck olanlar ise \u00fc\u00e7 faz sunar. Tek fazl\u0131 bir ba\u011flant\u0131 i\u00e7in \u015febeke taraf\u0131 ba\u011flant\u0131s\u0131 i\u00e7in \u00fc\u00e7 damarl\u0131 bir kablo ve \u00fc\u00e7 fazl\u0131 bir ba\u011flant\u0131 i\u00e7in be\u015f damarl\u0131 bir kablo gereklidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"AC_Nennleistung\"><\/span>AC nominal g\u00fc\u00e7<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">AC nominal g\u00fcc\u00fc eviricinin maksimum g\u00fcc\u00fcd\u00fcr ve bu nedenle kurulabilecek en y\u00fcksek FV g\u00fcc\u00fcd\u00fcr. Bu, bir invert\u00f6re AC nominal g\u00fcc\u00fcnden daha fazla FV mod\u00fcl ba\u011flanamayaca\u011f\u0131 anlam\u0131na gelir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Anzahl_MPP_Tracker\"><\/span>MPP izleyici say\u0131s\u0131<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bir inverterde bulunan MPP izleyicilerin say\u0131s\u0131 ba\u011flanabilecek dizilerin say\u0131s\u0131n\u0131 belirler. Daha k\u00fc\u00e7\u00fck invert\u00f6rlerde genellikle yaln\u0131zca bir MPP izleyici bulunurken, daha b\u00fcy\u00fck olanlarda iki veya daha fazla MPP izleyici bulunur. Ne kadar \u00e7ok MPP izleyici tak\u0131l\u0131rsa, inverterler o kadar pahal\u0131 olur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"MPP_Bereich\"><\/span>MPP aral\u0131\u011f\u0131<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Burada belirtilen DC voltaj aral\u0131\u011f\u0131, MPP izleyicide m\u00fcmk\u00fcn olan maksimum DC giri\u015f voltaj\u0131n\u0131 tan\u0131mlar. Bir dizide seri olarak birle\u015ftirilen t\u00fcm mod\u00fcllerin eklenen DC gerilimi \u00fcst s\u0131n\u0131r\u0131 a\u015fmamal\u0131d\u0131r. Aral\u0131k 360 ... olarak belirtilirse 600 V olarak belirtilirse, PV mod\u00fcl\u00fcn\u00fcn MPP voltaj\u0131 35 V olarak tan\u0131mlan\u0131r ve 600 \/ 35 = 17,14 ile sonu\u00e7lan\u0131r, yani bir dizi olarak seri halinde maksimum 17 mod\u00fcl m\u00fcmk\u00fcnd\u00fcr.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Eingangsstrom\"><\/span>Giri\u015f ak\u0131m\u0131<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Giri\u015f ak\u0131m\u0131, her bir dizinin bir mod\u00fcl\u00fcn\u00fcn MPP ak\u0131mlar\u0131n\u0131n eklenmesinden kaynaklanan t\u00fcm dizi ak\u0131mlar\u0131n\u0131n toplam\u0131n\u0131 g\u00f6sterir. Bir PV mod\u00fcl\u00fcn\u00fcn MPP ak\u0131m\u0131 9,92 A ise ve iki dizi kuruluysa, 9,92 + 9,92 19,84 A giri\u015f ak\u0131m\u0131 ile sonu\u00e7lan\u0131r.<br>Eviricinin yaln\u0131zca maksimum 16 A i\u015fleyebilece\u011fi varsay\u0131ld\u0131\u011f\u0131nda, ikinci diziye maksimum MPP ak\u0131m\u0131 16 - 9,92 = 6,08 A olan mod\u00fcller tak\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Leerlaufspannung\"><\/span>A\u00e7\u0131k devre gerilimi<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FV mod\u00fcllerin a\u00e7\u0131k devre gerilimi her zaman MPP geriliminden daha y\u00fcksektir. D\u00fc\u015f\u00fck d\u0131\u015f s\u0131cakl\u0131klarda daha y\u00fcksek ve y\u00fcksek s\u0131cakl\u0131klarda daha d\u00fc\u015f\u00fckt\u00fcr. Evirici \u00f6rne\u011fin 750 V maksimum a\u00e7\u0131k devre voltaj\u0131 g\u00f6steriyorsa, mod\u00fcl a\u00e7\u0131k devre voltaj\u0131 17 mod\u00fcl tak\u0131l\u0131yken 750 \/ 17 = 44 V'u ge\u00e7memelidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wirkungsgrad\"><\/span>Verimlilik<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Verimlilik, bir invert\u00f6r\u00fcn gelen DC gerilimini giden AC gerilimine d\u00f6n\u00fc\u015ft\u00fcrme verimlili\u011fini tan\u0131mlar. Bununla birlikte, verimlilik dalgalanan g\u00fcne\u015f yo\u011funlu\u011funa g\u00f6re de de\u011fi\u015fti\u011finden, voltaj ba\u011f\u0131ml\u0131l\u0131\u011f\u0131n\u0131n bilinmesi do\u011fru tasar\u0131m i\u00e7in \u00f6nemlidir. Kural olarak, daha d\u00fc\u015f\u00fck bir voltaj daha y\u00fcksek verimlilikle ili\u015fkilidir.<br>Bu ba\u011flamda, MPP aral\u0131\u011f\u0131n\u0131n \u00fcst s\u0131n\u0131r gerilimini kullanmak bu nedenle daha az verimlidir. Bu nedenle, invert\u00f6r sat\u0131n al\u0131rken daha y\u00fcksek bir mali harcama anlam\u0131na gelse de, birka\u00e7 dizili bir konfig\u00fcrasyon kullanmak daha iyidir.<\/p>","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Okuma s\u00fcresi<\/span> <span class=\"rt-time\"> 4<\/span> <span class=\"rt-label rt-postfix\">dakika<\/span><\/span>01.01.2021 itibariyle yasal durum Yeni EEG (Yenilenebilir Enerji Kaynaklar\u0131 Yasas\u0131), fotovoltaik sistemler de dahil olmak \u00fczere 01.01.2021 tarihinde y\u00fcr\u00fcrl\u00fc\u011fe girmi\u015ftir. Bu, eski ve yeni fotovoltaik sistemlerden 30 kWp'ye kadar ve 30 kWp dahil \u00f6z t\u00fcketimin EEG ek \u00fccretinden muaf oldu\u011fu anlam\u0131na gelir. Veri toplama i\u00e7in 7 kWp'ye kadar olan \u00f6z t\u00fcketimlerde ak\u0131ll\u0131 saya\u00e7 tak\u0131lmas\u0131na gerek yoktur.&nbsp;<a href=\"https:\/\/csiag.eu\/tr\/blog\/2023\/01\/12\/photovoltaik\/\" rel=\"bookmark\">Daha fazlas\u0131n\u0131 oku \"<span class=\"screen-reader-text\">Fotovoltaik<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[360,365],"tags":[937,928,927,938,940,799,934,941,447,931,939,935,936,932,933,812,930,926,929,741,446,925,529,644],"class_list":["post-3126","post","type-post","status-publish","format-standard","hentry","category-haus-und-garten","category-photovoltaik-fuer-daheim","tag-batteriebetrieb","tag-eeg-umlage","tag-eigenverbrauch","tag-eingangsphase","tag-eingangsstrom","tag-hybrid-wechselrichter","tag-lastgrenze","tag-leerlaufspannung","tag-leistung","tag-mpp-tracker","tag-nennleistung","tag-netzausfall","tag-netzfrequenz","tag-netzgefuehrt","tag-netzunabhaengig","tag-photovoltaik","tag-pv-modul","tag-rechtslage","tag-smartmeter","tag-string","tag-strom","tag-verguetung","tag-wechselrichter","tag-wirkungsgrad"],"modified_by":"Achim Goerner","_links":{"self":[{"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/posts\/3126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/comments?post=3126"}],"version-history":[{"count":0,"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/posts\/3126\/revisions"}],"wp:attachment":[{"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/media?parent=3126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/categories?post=3126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/csiag.eu\/tr\/wp-json\/wp\/v2\/tags?post=3126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}